6 resultados para Corneal refractive surgery

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To assess corneal wavefront-guided photorefractive keratectomy (PRK) to correct hyperopia after radial keratotomy (RK). SETTING: Sadalla Amin Ghanem Eye Hospital, Joinville, Santa Catarina, Brazil. DESIGN: Case series. METHODS: Excimer laser corneal wavefront-guided PRK with intraoperative mitomycin-C (MMC) 0.02% was performed. Main outcome measures were uncorrected (UDVA) and corrected (CDVA) distance visual acuities, spherical equivalent (SE), corneal aberrations, and haze. RESULTS: The mean time between RK and PRK in the 61 eyes (39 patients) was 18.8 years +/- 3.8 (SD). Before PRK, the mean SE was +4.17 +/- 1.97 diopters (D); the mean astigmatism, -1.39 +/- 1.04 D; and the mean CDVA, 0.161 +/- 0.137 logMAR. At 24 months, the mean values were 0.14 +/- 0.99 D (P<.001), -1.19 +/- 1.02 D (P=.627), and 0.072 +/- 0.094 logMAR (P<.001), respectively; the mean UDVA was 0.265 +/- 0.196 (P<.001). The UDVA was 20/25 or better in 37.7% of eyes and 20/40 or better in 68.9%. The CDVA improved by 1 or more lines in 62.3% of eyes. Two eyes (3.3%) lost 2 or more lines, 1 due to corneal ectasia. Thirty eyes (49.2%) were within +/- 0.50 D of intended SE and 45 (73.8%) were within +/- 1.00 D. From 6 to 24 months, the mean SE regression was +0.39 D (P<.05). A significant decrease in coma, trefoil, and spherical aberration occurred. Three eyes developed peripheral haze more than grade 1. CONCLUSION: Corneal wavefront-guided PRK with MMC for hyperopia after RK significantly improved UDVA, CDVA, and higher-order corneal aberrations with a low incidence of visually significant corneal haze.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

PURPOSE: To evaluate the sulcus anatomy and possible correlations between sulcus diameter and white-to-white (WTW) diameter in pseudophakic eyes, data that may be important in the stability of add-on intraocular lenses (IOLs). SETTING: University Eye Hospital, Tuebingen, Germany. DESIGN: Case series. METHODS: In pseudophakic eyes, the axial length (AL) and horizontal WTW were measured by the IOLMaster device. Cross-sectional images were obtained with a 50 MHz ultrasound biomicroscope on the 4 meridians: vertical, horizontal (180 degrees), temporal oblique, and nasal oblique. Sulcus-to-sulcus (STS), angle-to-angle (ATA), and sclera-to-sclera (ScTSc) diameters were measured. The IOL optic diameter (6.0 mm) served as a control. To test reliability, optic measurements were repeated 5 times in a subset of eyes. RESULTS: The vertical ATA and STS diameters were statistically significantly larger than the horizontal diameter (P=.0328 and P=.0216, respectively). There was no statistically significant difference in ScTSc diameters. A weak correlation was found between WTW and horizontal ATA (r = 0.5766, P<.0001) and between WTW and horizontal STS (r = 0.5040, P=.0002). No correlation was found between WTW and horizontal ScTSc (r = 0.2217, P=.1217). CONCLUSIONS: The sulcus anatomy had a vertical oval shape with the vertical meridian being the largest, but it also had variation in the direction of the largest meridian. The WTW measurements showed a weak correlation with STS. In pseudophakic eyes, Soemmerring ring or a bulky haptic may affect the ciliary sulcus anatomy.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: To determine whether the improvement in intermediate vision after bilateral implantation of an aspheric multifocal intraocular lens (IOL) with a +3.00 diopter (D) addition (add) occurs at the expense of optical quality compared with the previous model with a +4.00 D add. SETTING: Department of Ophthalmology, University of Sao Paulo, Sao Paulo, Brazil. DESIGN: Prospective randomized double-masked comparative clinical trial. METHODS: One year after bilateral implantation of Acrysof Restor SN6AD1 +3.00 D IOLs or Acrysof Restor SN6AD3 +4.00 D IOLs, optical quality was evaluated by analyzing the in vivo modulation transfer function (MTF) and point-spread function (expressed as Strehl ratio). The Strehl ratio and MTF curve with a 4.0 pupil and a 6.0 mm pupil were measured by dynamic retinoscopy aberrometry. The uncorrected and corrected distance visual acuities at 4 m, uncorrected and distance-corrected near visual acuities at 40 cm, and uncorrected and distance-corrected intermediate visual acuities at 50 cm, 60 cm, and 70 cm were measured. RESULTS: Both IOL groups comprised 40 eyes of 20 patients. One year postoperatively, there were no statistically significant between-group differences in the MTF or Strehl ratio with either pupil size. There were no statistically significant between-group differences in distance or near visual acuity. Intermediate visual acuity was significantly better in the +3.00 D IOL group. CONCLUSION: Results indicate that the improvement in intermediate vision in eyes with the aspheric multifocal +3.00 D add IOL occurred without decreasing optical quality over that with the previous version IOL with a +4.00 D add.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Accurate alignment of a toric intraocular lens (IOL) is a requisite to achieving the intended reduction in astigmatism at the time of cataract surgery. However, it requires a reasonably clear view of the limbal vascular anatomy, which is sometimes altered by chemosis from a subconjunctival anesthetic injection or a hemorrhage. We describe a technique that can quickly restore vascular anatomy and facilitate toric IOL alignment.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We describe a technique to rescue the continuous curvilinear capsulorhexis (CCC) in cases in which complete radial tears make it impossible to use normal traction forceps. A circumferential path and rapid movement are applied in the plane of the anterior capsule in the direction of the center pupil. This technique was used in 50 cases. In 47, the CCC could be completed; in 3, it could not and surgery was continued with low-parameter phacoemulsification. No other intraoperative complications occurred.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

How is the corneal epithelium restored when all of it plus the limbus have been eliminated? This investigation explored the possibility that this may be achieved through the conjunctival epithelium. The corneal epithelium of the right eye of 12 rabbits (Oryctolagus cuniculus) was totally scraped followed by surgical excision of the limbus plus 1.0-1.5 mm of the adjacent conjunctiva. Antibiotics and corticosteroids were applied for 1 week after surgery. Histological and immunohistochemical techniques were used to monitor the events taking place on the eye surface 2 weeks and 1, 3 and 6 months thereafter. Initially, the corneal surface was covered by conjunctival-like epithelium. After 1 month and more prominently at 3 and 6 months an epithelium displaying the morphological features of the cornea and reacting with the AE5 antibody was covering the central region. It is likely that the corneal epithelium originated from undifferentiated cells of the conjunctiva interacting with the corneal stroma.