7 resultados para Continuous glucose monitoring
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
Background: This pilot study aimed to verify if glycemic control can be achieved in type 2 diabetes patients after acute myocardial infarction (AMI), using insulin glargine (iGlar) associated with regular insulin (iReg), compared with the standard intensive care unit protocol, which uses continuous insulin intravenous delivery followed by NPH insulin and iReg (St. Care). Patients and Methods: Patients (n = 20) within 24 h of AMI were randomized to iGlar or St. Care. Therapy was guided exclusively by capillary blood glucose (CBG), but glucometric parameters were also analyzed by blinded continuous glucose monitoring system (CGMS). Results: Mean glycemia was 141 +/- 39 mg/dL for St. Care and 132 +/- 42 mg/dL for iGlar by CBG or 138 +/- 35 mg/dL for St. Care and 129 +/- 34 mg/dL for iGlar by CGMS. Percentage of time in range (80-180 mg/dL) by CGMS was 73 +/- 18% for iGlar and 77 +/- 11% for St. Care. No severe hypoglycemia (<= 40 mg/dL) was detected by CBG, but CGMS indicated 11 (St. Care) and seven (iGlar) excursions in four subjects from each group, mostly in sulfonylurea users (six of eight patients). Conclusions: This pilot study suggests that equivalent glycemic control without increase in severe hyperglycemia may be achieved using iGlar with background iReg. Data outputs were controlled by both CBG and CGMS measurements in a real-life setting to ensure reliability. Based on CGMS measurements, there were significant numbers of glycemic excursions outside of the target range. However, this was not detected by CBG. In addition, the data indicate that previous use of sulfonylurea may be a potential major risk factor for severe hypoglycemia irrespective of the type of insulin treatment.
Resumo:
Background To determine the characteristics of clinical care offered to type 1 diabetic patients across the four distinct regions of Brazil, with geographic and contrasting socioeconomic differences. Glycemic control, prevalence of cardiovascular risk factors, screening for chronic complications and the frequency that the recommended treatment goals were met using the American Diabetes Association guidelines were evaluated. Methods This was a cross-sectional, multicenter study conducted from December 2008 to December 2010 in 28 secondary and tertiary care public clinics in 20 Brazilian cities in north/northeast, mid-west, southeast and south regions. The data were obtained from 3,591 patients (56.0% females and 57.1% Caucasians) aged 21.2 ± 11.7 years with a disease duration of 9.6 ± 8.1 years (<1 to 50 years). Results Overall, 18.4% patients had HbA1c levels <7.0%, and 47.5% patients had HbA1c levels ≥ 9%. HbA1c levels were associated with lower economic status, female gender, age and the daily frequency of self-blood glucose monitoring (SBGM) but not with insulin regimen and geographic region. Hypertension was more frequent in the mid-west (32%) and north/northeast (25%) than in the southeast (19%) and south (17%) regions (p<0.001). More patients from the southeast region achieved LDL cholesterol goals and were treated with statins (p<0.001). Fewer patients from the north/northeast and mid-west regions were screened for retinopathy and nephropathy, compared with patients from the south and southeast. Patients from the south/southeast regions had more intensive insulin regimens than patients from the north/northeast and mid-west regions (p<0.001). The most common insulin therapy combination was intermediate-acting with regular human insulin, mainly in the north/northeast region (p<0.001). The combination of insulin glargine with lispro and glulisine was more frequently used in the mid-west region (p<0.001). Patients from the north/northeast region were younger, non-Caucasian, from lower economic status, used less continuous subcutaneous insulin infusion, performed less SBGM and were less overweight/obese (p<0.001). Conclusions A majority of patients, mainly in the north/northeast and mid-west regions, did not meet metabolic control goals and were not screened for diabetes-related chronic complications. These results should guide governmental health policy decisions, specific to each geographic region, to improve diabetes care and decrease the negative impact diabetes has on the public health system.
Resumo:
This article reports, in a systemized and analytical way, the experience of an Outreach Program in the period between 2010 and 2011. The study focused on health education interventions as strategies to improve the adherence of individuals with insulin- dependent diabetes mellitus (IDDM), clients of a blood glucose self-Monitoring program. In addition, we intended to contribute to the reorganization of the program's working processes in the unit. Health education strategies were used in both educational groups and home visits, thus permitting the provision of care that was more individualized. Data regarding the clients were organized on a spreadsheet and in files for the Family Health teams, which made it easier to identify the patients, including those who were absent, helping to decentralize the care. By using health education strategies, we intended to contribute to a more comprehensive and emancipatory care of the clients, aimed at a continuous reflection of the workers regarding their practices.
Resumo:
This article describes a new design for a paper-based electrochemical system for flow injection analysis. Capillary wicking facilitates a gravity-driven flow of buffer solution continuously through paper and nitrocellulose, from a buffer reservoir at one end of the device to a sink at the other. A difference in height between the reservoir and the sink leads to a continuous and constant flow. The nitrocellulose lies horizontally on a working electrode, which consists of a thin platinum layer deposited on a solid support. The counter and reference electrodes are strategically positioned upstream in the buffer reservoir. A simple pipetting device was developed for reliable application of (sub)microliter volumes of sample without the need of commercial micropipets; this device did not damage the nitrocellulose membrane. Demonstration of the system for the determination of the concentration of glucose in urine resulted in a noninvasive, quantitative assay that could be used for diagnosis and monitoring of diabetes. This method does not require disposable test strips, with enzyme and electrodes, that are thrown away after each measurement Because of its low cost, this system could be used in medical environments that are resource-limited.
Resumo:
OBJECTIVE: To assess the metabolic control of diabetes mellitus patients registered in a capillary glucose self-monitoring program at home. METHODS: In this longitudinal retrospective study, 97 subjects at four health institutions in a Brazilian city were followed during 37 months between 2005 and 2008. The health files were analyzed of patients selected to register the evolution of variables related to capillary glucose self-monitoring at home and metabolic control of diabetes mellitus. RESULTS: During the assessment, both mean and monthly percentages of capillary blood glucose measurements at home decreased from 34.1 (65.1%) to 33.6 (64.8%), respectively (p <0.001). Mean HbA1c levels dropped from 9.20% to 7.94% (p<0.001). HDL cholesterol decreased from 51 mg/dl to 47 mg/dl (p=0.001). CONCLUSION: Patients' metabolic control improved, characterized by a significant reduction in HbA1C.
Resumo:
Ceftazidime is a broad spectrum antibiotic administered mainly by the parenteral route, and it is especially effective against Pseudomonas aeruginosa. The period of time in which serum levels exceed the Minimum Inhibitory Concentration (MIC) is an important pharmacodynamic parameter for its efficacy. One of the forms to extend this period is to administer the antibiotic by continuous infusion, after prior dilution in a Parenteral Solution (PS). The present work assessed the stability of ceftazidime in 5% glucose PS for 24 hours, combined or not with aminophylline, through High Performance Liquid Chromatography (HPLC). The physicochemical evaluation was accompanied by in vitro antimicrobial activity compared MIC test in the 24-hour period. Escherichia coli and Pseudomonas aeruginosa were the microorganisms chosen for the MIC comparison. The HPLC analysis confirmed ceftazidime and aminophylline individual stability on PS, while the MIC values were slightly higher than the mean described in the literature. When both drugs were associated in the same PS, the ceftazidime concentration by HPLC decreased 25% after 24 hours. Not only did the MIC values show high loss of antibiotic activity within the same period, but also altered MIC values immediately after the preparation, which was not detected by HPLC. Our results indicate that this drug combination is not compatible, even if used right away, and that PS might not be the best vehicle for ceftazidime, emphasizing the importance of the MIC evaluation for drug interactions.
Resumo:
Ceftazidime is a broad spectrum antibiotic administered mainly by the parenteral route, and it is especially effective against Pseudomonas aeruginosa. The period of time in which serum levels exceed the Minimum Inhibitory Concentration (MIC) is an important pharmacodynamic parameter for its efficacy. One of the forms to extend this period is to administer the antibiotic by continuous infusion, after prior dilution in a Parenteral Solution (PS). The present work assessed the stability of ceftazidime in 5% glucose PS for 24 hours, combined or not with aminophylline, through High Performance Liquid Chromatography (HPLC). The physicochemical evaluation was accompanied by in vitro antimicrobial activity compared MIC test in the 24-hour period. Escherichia coli and Pseudomonas aeruginosa were the microorganisms chosen for the MIC comparison. The HPLC analysis confirmed ceftazidime and aminophylline individual stability on PS, while the MIC values were slightly higher than the mean described in the literature. When both drugs were associated in the same PS, the ceftazidime concentration by HPLC decreased 25% after 24 hours. Not only did the MIC values show high loss of antibiotic activity within the same period, but also altered MIC values immediately after the preparation, which was not detected by HPLC. Our results indicate that this drug combination is not compatible, even if used right away, and that PS might not be the best vehicle for ceftazidime, emphasizing the importance of the MIC evaluation for drug interactions.