21 resultados para Cone, Spencer Houghton, 1785-1855.

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE. To measure heterochromatic flicker electroretinograms (ERGs) at high (36 Hz) and intermediate (12 Hz) temporal frequencies to evaluate luminance and cone opponent responses, respectively, in glaucoma eyes with (perimetric) and without (preperimetric) visual field defects. METHODS. Flicker ERGs were recorded from one randomly chosen dilated eye of 32 patients (mean age, 61 +/- 11 years; 15 men, 17 women) from the Erlangen Glaucoma Registry and from 24 healthy volunteers (mean age, 43 +/- 11 years; 14 men, 10 women). Red and green light-emitting diodes in a Ganzfeld stimulator were sine wave-modulated in counterphase. The responses were measured at 36 Hz, the frequency at which ERGs reflect activity of the luminance pathway, and at 12 Hz, the frequency at which ERGs reflect chromatic activity. RESULTS. Response amplitudes were similar in glaucoma patients and controls. Phase differences were observed in patients with visual field defects (perimetric) compared with the control group at 36 and 12 Hz in the first harmonic and second harmonic responses. Patients without visual field defects (preperimetric) showed phase differences for the second harmonic component at 36 Hz. No age effect on response amplitudes and phases was found in any of the subject groups (controls and patients). CONCLUSIONS. The responses displayed phase differences but not amplitude differences in perimetric glaucoma patients at both 36 and 12 Hz, suggesting that both magnocellular and parvocellular pathways are affected. Preperimetric glaucoma patients also showed phase differences. The response phase may be sensitive to early dysfunction of the inner retina. (ClinicalTrials.gov number, NCT00494923.) (Invest Ophthalmol Vis Sci. 2011;52:6757-6765) DOI:10.1167/iovs.11-7538

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Transient visual evoked cortical potentials (VECP) were recorded from the scalp of healthy normal trichromats (n = 12). VECPs were elicited by onset/offset presentation of patterned stimuli of two kinds: isochromatic luminance-modulated, and equiluminant red-green modulated, sine wave gratings. The amplitude and latency of the major onset components of the onset/offset VECP were measured and plotted as a function of the logarithm of pooled cone contrast. The early onset components, achromatic C1 and chromatic N1, increase linearly with log contrast, but N1 has a higher contrast gain than C1. The late onset components, achromatic C2 and chromatic N2, have similar contrast gain, and similar response as a function of contrast level: both increase in the low-to-medium range of contrasts and saturate at high contrast levels. In the range of pooled cone contrast tested, C1 and N1 show similar latencies, whilst C2 shows shorter latencies than N2. We suggest that C1 and N1 are generated by the same visual mechanism with high red-green contrast gain and low luminance contrast gain, whilst C2 and N2 are generated by different visual mechanisms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the study was to investigate whether there is an ocular interaction in the flicker ERG responses reflecting luminance and cone opponency in normal human subjects. Flicker ERGs were recorded from one dilated eye of 10 healthy volunteers. Each subject was tested twice: once with and once without occluding the opposite eye. Red and green LEDs were modulated in counterphase in a Ganzfeld stimulator. ERG responses were recorded for different ratios of the modulation in the red and green LEDs and at 12 and 36 Hz. The amplitudes and phases of the fundamental components were compared between the conditions with and without occlusion. The 12-Hz flicker ERGs reflected activity of the cone opponent channel, whereas the 36-Hz data reflected luminance activity. There were no significant differences between the conditions with and without occluding the opposite eye for any of the stimulus protocols. Ocular interaction is absent in flicker ERGs reflecting cone opponent and luminance activity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigated the color vision pattern in Cebus apella monkeys by means of electroretinogram measurements (ERG) and genetic analysis. Based on ERG we could discriminate among three types of dichromatic males. Among females, this classification is more complex and requires additional genetic analysis. We found five among 10 possible different phenotypes, two trichromats and three dichromats. We also found that Cebus present a new allele with spectral peak near 552 nm, with the amino acid combination SFT at positions 180, 277 and 285 of the opsin gene, in addition to the previously described SYT, AFT and AFA alleles. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE. The expression of S- and M-opsins in the murine retina is altered in different transgenic mouse models with mutations in the thyroid hormone receptor (TR)-beta gene, demonstrating an important role of thyroid hormone (TH) in retinal development. METHODS. The spatial expression of S- and M-opsin was compared in congenital hypothyroidism and in two different TR mutant mouse models. One mouse model contains a ligand-binding mutation that abolishes TH binding and results in constitutive binding to nuclear corepressors. The second model contains a mutation that blocks binding of coactivators to the AF-2 domain without affecting TH binding. RESULTS. Hypothyroid newborn mice showed an increase in S- opsin expression that was completely independent of the genotype. Concerning M-opsin expression, hypothyroidism caused a significant decrease (P < 0.01) only in wild-type animals. When TR beta 1 and -beta 2 were T3-binding defective, the pattern of opsin expression was similar to TR beta ablation, showing increased S- opsin expression in the dorsal retina and no expression of M-opsin in the entire retina. In an unexpected finding, immunostaining for both opsins was detected when both subtypes of TR beta were mutated in the helix 12 AF-2 domain. CONCLUSIONS. The results show, for the first time, that the expression of S- and M-opsin is dependent on normal thyroid hormone levels during development.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many animal species make use of ultraviolet (UV) light in a number of behaviors, such as feeding and mating. The goldfish (Carassius auratus) is among those with a UV photoreceptor and pronounced UV sensitivity. Little is known, however, about the retinal processing of this input. We addressed this issue by recording intracellularly from second-order neurons in the adult goldfish retina. In order to test whether cone-driven horizontal cells (HCs) receive UV cone inputs, we performed chromatic adaptation experiments with mono- and biphasic HCs. We found no functional evidence of a projection from the UV-sensitive cones to these neurons in adult animals. This suggests that goldfish UV receptors may contact preferentially triphasic HCs, which is at odds with the hypothesis that all cones contact all cone-driven HC types. However, we did find evidence of direct M-cone input to monophasic HCs, favoring the idea that cone-HC contacts are more promiscuous than originally proposed. Together, our results suggest that either UV cones have a more restricted set of post-synaptic partners than the other three cone types, or that the UV input to mono- and biphasic HCs is not very pronounced in adult animals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE. To better understand the relative contributions of rod, cone, and melanopsin to the human pupillary light reflex (PLR) and to determine the optimal conditions for assessing the health of the rod, cone, and melanopsin pathways with a relatively brief clinical protocol. METHODS. PLR was measured with an eye tracker, and stimuli were controlled with a Ganzfeld system. In experiment 1, 2.5 log cd/m(2) red (640 +/- 10 nm) and blue (467 +/- 17 nm) stimuli of various durations were presented after dark adaptation. In experiments 2 and 3, 1-second red and blue stimuli were presented at different intensity levels in the dark (experiment 2) or on a 0.78 log cd/m(2) blue background (experiment 3). Based on the results of experiments 1 to 3, a clinical protocol was designed and tested on healthy control subjects and patients with retinitis pigmentosa and Leber`s congenital amaurosis. RESULTS. The duration for producing the optimal melanopsin-driven sustained pupil response after termination of an intense blue stimulus was 1 second. PLR rod-and melanopsin-driven components are best studied with low-and high-intensity flashes, respectively, presented in the dark (experiment 2). A blue background suppressed rod and melanopsin responses, making it easy to assess the cone contribution with a red flash (experiment 3). With the clinical protocol, robust melanopsin responses could be seen in patients with few or no contributions from the rods and cones. CONCLUSIONS. It is possible to assess the rod, cone, and melanopsin contributions to the PLR with blue flashes at two or three intensity levels in the dark and one red flash on a blue background. (Invest Ophthalmol Vis Sci. 2011; 52: 6624-6635) DOI: 10.1167/iovs.11-7586

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The `Critically Endangered` Cone-billed Tanager Conothraupis mesoleuca was described in 71 93 9, based on a single specimen collected in the state of Mato Grosso, western Brazil. Not seen again in the wild until 2003, this poorly-known species was rediscovered in Emas National Park, in the Brazilian state of Goias. We describe here the discovery of a new population of Cone-billed Tanager in Chapada dos Parecis, along the upper Juruena River basin, in the state of Mato Grosso. The birds were always detected in (or near) flooded habitats along rivers. At least 40 individuals were found, but the population may be larger since areas of potential habitat are available in the upper Juruena basin and these have not yet been surveyed. We also provide here the first information on the biology and behaviour of the species based on observations in Juruena and Emas, as well as a first description of the female. Historical documents and our records support our suggestion that ""Juruena"", i.e. the type locality of the Cone-billed Tanager, refers to the Juruena telegraph station (12 degrees 50`S, 58 degrees 55`W). Considering that the range of the species is being settled, research on different aspects of its biology are urgent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate the accuracy of cone-beam computed tomography (CBCT) for measuring the buccal bone volume around dental implants. Materials and methods: Three to six implants were inserted into the anterior maxilla of eight skulls, depending on the availability of bone, and after this, the CBCT was performed. By means of CBCT image, measurements of the bone wall at three points of the implant were obtained, analyzed and compared with those obtained in the plaster skull casting. Results: The results showed that for the three points of the implants, no statistically significant difference in the measurements was obtained from the plaster model and CBCT images. Conclusions: CBCT can be a useful tool for assessing buccal bone volume along the implant. To cite this article:?Shiratori LN, Marotti J, Yamanouchi J, Chilvarquer I, Contin I, Tortamano-Neto P. Measurement of buccal bone volume of dental implants by means of cone-beam computed tomography.?Clin. Oral Impl. Res. 23, 2012; 797804.?doi: 10.1111/j.1600-0501.2011.02207.x

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The objective of the study was to evaluate the ability of large-volume cone-beam computed tomography (CBCT) to detect horizontal root fracture and to test the influence of a metallic post. Methods: Through the examination of 40 teeth by large-volume CBCT (20-cm height and 15-cm diameter cylinder) at 0.2-mm voxel resolution, 2 observers analyzed the samples for the presence and localization of horizontal root fracture. Results: The values of accuracy in the groups that had no metallic post ranged from 33%-68%, whereas for the samples with the metallic post, values showed a wide variation (38%-83%). Intraobserver agreement showed no statistically significant difference between the groups with/without metallic post; both ranged from very weak to weak (kappa, 0.09-0.369). Conclusions: The low accuracy and low intraobserver and interobserver agreement reflect the difficulty in performing an adequate diagnosis of horizontal root fractures through a large-volume CBCT by using a small voxel reconstruction. (J Endod 2012;38:856-859)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The neurovascular bundle may be vulnerable during surgical procedures involving the mandible, especially when anatomical variations are present. Increased demand of implant surgeries, wider availability of three-dimensional exams, and lack of clear definitions in the literature indicate that features of anatomical variations should be revisited. The objective of the study was to evaluate features of anatomical variations related to mandibular canal (MC), such as bifid canals, anterior loop of mental nerve, and corticalization of MC. Additionally, bone trabeculation at the submandibular gland fossa region (SGF) was assessed and related to visibility of MC. Cone beam computed tomography exams from 100 patients (200 hemimandibles) were analyzed and the following parameters were registered: diameter and corticalization of MC; trabeculation in SGF region; presence of bifid MC, position of bifurcations, diameter, and direction of bifid canals; and measurement of anterior loops by two methods. Corticalization of the MC was observed in 59% of hemimandibles. In 23%, MC could be identified despite absence of corticalization. Diameter of MC was between 2.1 and 4 mm for nearly three quarters of the sample. In 80% of the sample trabeculation at the SGF was either decreased or not visible, and such cases showed correlation with absence of MC corticalization. Bifid MC affected 19% of the patients, mostly associated with additional mental foramina. Clinically significant anterior loop (> 2 mm of anterior extension) was observed in 22-28%, depending on the method. Our findings, together with previously reported limitations of conventional exams, draw attention to the unpredictability related to anatomical variations in neurovascularization, showing the contribution of individual assessment through different views of three-dimensional imaging prior to surgical procedures in the mandible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cone beam computed tomography (CBCT) can be considered as a valuable imaging modality for improving diagnosis and treatment planning to achieve true guidance for several craniofacial surgical interventions. A new concept and perspective in medical informatics is the highlight discussion about the new imaging interactive workflow. The aim of this article was to present, in a short literature review, the usefulness of CBCT technology as an important alternative imaging modality, highlighting current practices and near-term future applications in cutting-edge thought-provoking perspectives for craniofacial surgical assessment. This article explains the state of the art of CBCT improvements, medical workstation, and perspectives of the dedicated unique hardware and software, which can be used from the CBCT source. In conclusion, CBCT technology is developing rapidly, and many advances are on the horizon. Further progress in medical workstations, engineering capabilities, and improvement in independent software-some open source-should be attempted with this new imaging method. The perspectives, challenges, and pitfalls in CBCT will be delineated and evaluated along with the technological developments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Owing to a lack of symptoms and difficult visualization in routine intraoral radiographs, diagnosis of external root resorptions can be challenging. Aim: The goal of this study was to compare two image acquisition methods, intraoral radiographs and cone beam computed tomography (CBCT), in the diagnosis of external resorption. Material and Methods: Thirty-four maxillary and mandibular bicuspids were divided into three groups. Perforations measuring 0.3 and 0.6 mm in diameter and 0.15 and 0.3 mm in depth, respectively, were made on the lingual root surfaces in thirty teeth, and four were used as controls. Next, teeth were mounted on an apparatus and radiographed at mesial, distal, and orthoradial angulations. CBCT images were also taken. The analysis of the intraoral radiographic and tomographic images was carried out by two experts using standardized scores. Data were then compared statistically. Results: A strong agreement between the examiners was observed in both diagnosis methods, the intraoral radiographic (r = 0.93) and the tomographic analysis (r = 1.0). Tomography had higher statistically significant detection values than intraoral radiography (P < 0.05). In intraoral radiographs, the detection was significantly greater (P < 0.05) in the mandibular bicuspids, compared with their maxillary counterparts. The ability to detect 0.6-mm perforations by intraoral radiography was significantly higher than that of 0.3-mm perforations (P < 0.05). Conclusion: Cone beam computed tomography showed better diagnostic ability compared with intraoral radiography, regardless of the tooth or the dimensions of the resorption evaluated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present article discusses an atrophic maxilla reconstruction with iliac crest bone block and particulate grafts and dental implants. Onlay block grafts were used to restore bone volume of the anterior maxilla, whereas bilateral sinus floor augmentation was performed using a particulate graft. Ten months after the grafting surgery, 9 dental implants were placed to rehabilitate the case. Results of a 7-year follow-up were obtained clinically and by cone beam computed tomographic images.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Cone-beam computed tomography (CBCT) is a reliable method of assessing the oral cavity and upper airways. We conducted this study to examine the changes introduced by rapid maxillary expansion in the nasal cavity, nasopharynx, and oropharynx as seen with images obtained by CBCT. Materials and Methods: We evaluated 15 patients with maxillary width deficiency treated with RME. Patients were subjected to CBCT at the beginning of RME and after the retention period of 4 months. Results: The nasal cavity presented a significant transverse increase in the lower third, in the anterior (1.08 mm +/- 0.15), medium (1.28 mm +/- 0.15), and posterior regions (0.77 mm +/- 0.12). No significant change occurred in the nasopharynx in volume (P = .11), median sagittal area (P = .33), or lower axial area (P = .29) resulting from the RME. A significant change was noted in the oropharynx in volume (P = .05), median sagittal area (P = .01), and lower axial area (P = .04) before and immediately after the RME. Conclusions: RME is able to increase the transverse width of the nasal cavity, but it does not have the same effect in the nasopharynx. Changes noted in the oropharynx may be due to the lack of a standardized position of the head and tongue at the time of image acquisition. (Angle Orthod. 2012;82:458-463.)