4 resultados para Computerized analysis
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
Nowadays, image analysis is one of the most modern tools in evaluating physiological potential of seeds. This study aimed at verifying the efficiency of the seedling imaging analysis to assess physiological potential of wheat seeds. The seeds of wheat, cultivars IAC 370 and IAC 380, each of which represented by five different lots, were stored during four months under natural environmental conditions of temperature (T) and relative humidity (RH), in municipality of Piracicaba, Stated of São Paulo, Brazil. For this, bimonthly assessments were performed to quantify moisture content and physiological potential of seeds by means of tests of: germination, first count, accelerated aging, electrical conductivity, seedling emergence, and computerized analysis of seedlings, using the Seed Vigor Imaging System (SVIS®). It has been concluded that the computerized analyses of seedling through growth indexes and vigor, using the SVIS®, is efficient to assess physiological potential of wheat seeds.
Resumo:
Objective: The aim of the present study was to investigate the FHR parameters in term pregnancies complicated by asthma. Study design: prospective cross-sectional study performed between July 2008 and November 2009. Twenty-one singleton pregnancy between 36 and 40 weeks gestation with diagnosis of maternal asthma and no current use of oral corticosteroids were compared with 30 pregnancies without morbidities at the same gestational age. The computerized cardiotocography (System 8002, Sonicaid) was performed and 30 min analysis was studied. Statistical analysis included Student's t-test or Mann-Whitney U test for comparisons between groups. Categorical data were compared using the chi(2)-test or Fisher's exact test. Results: There were no significant differences in FHR parameters analyzed by computerized cardiotocography: basal FHR (p = 0.80), number of accelerations >10 bpm (p = 0.08) or >15 bpm (p = 0.20), duration of high episodes (p = 0.70), duration of low episodes (p = 0.46) and STV (p = 0.66). Asthmatic mothers presented mean number of fetal movement per hour significantly lower than control group (34.6 +/- 28.2 vs. 60.6 +/- 43.1, p = 0.02). Conclusion: Computerized cardiotocography demonstrates no association between the abnormal parameters of FHR and maternal asthma in term pregnancies. Maternal asthma was associated with less fetal movements per hour, suggesting further studies on the counting of fetal movements in pregnant women with asthma.
Resumo:
Seven sides of cadaver heads were used to compare the surgical exposures provided by the mini-modified orbitozygomatic (MOz) and supra-orbital (SO) approaches. The Optotrak 3020 computerized tracking system (Northern Digital, Waterloo, ON, Canada) was utilized to evaluate the area of anatomical exposure defined by six points: (1) ipsilateral sphenoid ridge; (2) most distal point of the ipsilateral middle cerebral artery (MCA); (3) most distal point of the ipsilateral posterior cerebral artery (PCA); (4) most distal point of the contralateral PCA; (5) most distal point of the contralateral MCA; and (6) contralateral sphenoid ridge. Additionally, angles of approach for the ipsilateral MCA bifurcation, ipsilateral ICA bifurcation, basilar artery tip, contralateral MCA and ICA bifurcation and anterior communicating artery (AcomA) were evaluated, first for SO and then for MOz. An image guidance system was used to evaluate the limits of surgical exposure. No differences in the area of surgical exposure were noted (p > 0.05). Vertical angles were significantly wider for the ipsilateral and contralateral ICA bifurcation, AcomA, contralateral MCA and basilar tip (p < 0.05) for MOz. No differences in horizontal angles were observed between the approaches for the six targets (p > 0.05). There were no differences in the limits of exposure. MOz affords no additional surgical working space. However, our results demonstrate systematically that vertical exposure is improved. The MOz should be performed while planning an approach to these regions and a wider exposure in the vertical axis is needed. (C) 2012 Elsevier Ltd. All rights reserved.
Resumo:
Purpose: To describe a new computerized method for the analysis of lid contour based on the measurement of multiple radial midpupil lid distances. Design: Evaluation of diagnostic technology. Participants and Controls: Monocular palpebral fissure images of 35 patients with Graves' upper eyelid retraction and of 30 normal subjects. Methods: Custom software was used to measure the conventional midpupil upper lid distance (MPLD) and 12 oblique MPLDs on each 15 degrees across the temporal (105 degrees, 120 degrees, 135 degrees, 150 degrees, 165 degrees, and 180 degrees) and nasal (75 degrees, 60 degrees, 45 degrees, 30 degrees, 15 degrees, and 0 degrees) sectors of the lid fissure. Main Outcome Measures: Mean, standard deviation, 5th and 95th percentiles of the oblique MPLDs obtained for patients and controls. Temporal/nasal MPLD ratios of the same angles with respect to the midline. Results: The MPLDs increased from the vertical midline in both nasal and temporal sectors of the fissure. In the control group the differences between the mean central MPLD (90 degrees) and those up to 30 degrees in the nasal (75 degrees and 60 degrees) and temporal sectors (105 degrees and 120 degrees) were not significant. For greater eccentricities, all temporal and nasal mean MPLDs increased significantly. When the MPLDs of the same angles were compared between groups, the mean values of the Graves' patients differed from control at all angles (F = 4192; P<0.0001). The greatest temporal/nasal asymmetry occurred 60 degrees from the vertical midline. Conclusions: The measurement of radial MPLD is a simple and effective way to characterize lid contour abnormalities. In patients with Graves' upper eyelid retraction, the method demonstrated that the maximum amplitude of the lateral lid flare sign occurred at 60 degrees from the vertical midline. Financial Disclosure(s): The authors have no proprietary or commercial interest in any of the materials discussed in this article. Ophthalmology 2012; 119: 625-628 (C) 2012 by the American Academy of Ophthalmology.