8 resultados para Complementary metal–oxide–semiconductor (CMOS)
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
In accelerating dark energy models, the estimates of the Hubble constant, Ho, from Sunyaev-Zerdovich effect (SZE) and X-ray surface brightness of galaxy clusters may depend on the matter content (Omega(M)), the curvature (Omega(K)) and the equation of state parameter GO. In this article, by using a sample of 25 angular diameter distances of galaxy clusters described by the elliptical beta model obtained through the SZE/X-ray technique, we constrain Ho in the framework of a general ACDM model (arbitrary curvature) and a flat XCDM model with a constant equation of state parameter omega = p(x)/rho(x). In order to avoid the use of priors in the cosmological parameters, we apply a joint analysis involving the baryon acoustic oscillations (BA()) and the (MB Shift Parameter signature. By taking into account the statistical and systematic errors of the SZE/X-ray technique we obtain for nonflat ACDM model H-0 = 74(-4.0)(+5.0) km s(-1) Mpc(-1) (1 sigma) whereas for a fiat universe with constant equation of state parameter we find H-0 = 72(-4.0)(+5.5) km s(-1) Mpc(-1)(1 sigma). By assuming that galaxy clusters are described by a spherical beta model these results change to H-0 = 6(-7.0)(+8.0) and H-0 = 59(-6.0)(+9.0) km s(-1) Mpc(-1)(1 sigma), respectively. The results from elliptical description are in good agreement with independent studies from the Hubble Space Telescope key project and recent estimates based on the Wilkinson Microwave Anisotropy Probe, thereby suggesting that the combination of these three independent phenomena provides an interesting method to constrain the Bubble constant. As an extra bonus, the adoption of the elliptical description is revealed to be a quite realistic assumption. Finally, by comparing these results with a recent determination for a, flat ACDM model using only the SZE/X-ray technique and BAO, we see that the geometry has a very weak influence on H-0 estimates for this combination of data.
Resumo:
Gamasiphis Berlese is one of the most diverse genera of Ologamasidae, with 68 described species, corresponding to about 15% of the species of the family. Until now, a single species of this genus was known from Brazil. Gamasiphis salvadori sp. nov., Gamasiphis flechtmanni sp. nov. and Gamasiphis edmilsoni sp. nov. are described based on the morphology of adult females and males collected from litter and soil in Piracicaba, Sao Paulo State, Brazil. The holotype of Gamasiphis plenosetosus Karg, 1994 was examined, given its close similarity with the latter species, and complementary morphological information about it is provided. A key for the separation of females of the 60 recognizable world species of Gamasiphis is provided.
Resumo:
This paper describes a CMOS implementation of a linear voltage regulator (LVR) used to power up implanted physiological signal systems, as it is the case of a wireless blood pressure biosensor. The topology is based on a classical structure of a linear low-dropout regulator. The circuit is powered up from an RF link, thus characterizing a passive radio frequency identification (RFID) tag. The LVR was designed to meet important features such as low power consumption and small silicon area, without the need for any external discrete components. The low power operation represents an essential condition to avoid a high-energy RF link, thus minimizing the transmitted power and therefore minimizing the thermal effects on the patient's tissues. The project was implemented in a 0.35-mu m CMOS process, and the prototypes were tested to validate the overall performance. The LVR output is regulated at 1 V and supplies a maximum load current of 0.5 mA at 37 degrees C. The load regulation is 13 mV/mA, and the line regulation is 39 mV/V. The LVR total power consumption is 1.2 mW.
Resumo:
In this paper, we proposed a new three-parameter long-term lifetime distribution induced by a latent complementary risk framework with decreasing, increasing and unimodal hazard function, the long-term complementary exponential geometric distribution. The new distribution arises from latent competing risk scenarios, where the lifetime associated scenario, with a particular risk, is not observable, rather we observe only the maximum lifetime value among all risks, and the presence of long-term survival. The properties of the proposed distribution are discussed, including its probability density function and explicit algebraic formulas for its reliability, hazard and quantile functions and order statistics. The parameter estimation is based on the usual maximum-likelihood approach. A simulation study assesses the performance of the estimation procedure. We compare the new distribution with its particular cases, as well as with the long-term Weibull distribution on three real data sets, observing its potential and competitiveness in comparison with some usual long-term lifetime distributions.
Resumo:
We propose a slow-wave MEMS phase shifter that can be fabricated using the CMOS back-end and an additional maskless post-process etch. The tunable phase shifter concept is formed by a conventional slow-wave transmission line. The metallic ribbons that form the patterned floating shield of this type of structure are released to allow motion when a control voltage is applied, which changes the characteristic impedance and the phase velocity. For this device a quality factor greater than 40 can be maintained, resulting in a figure of merit on the order of 0.7 dB/360 degrees and a total area smaller than 0.14 mm(2) for a 60-GHz working frequency. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
The objective of this study was to verify the effect of acupuncture on the sleep quality of obese workers in a teaching hospital. Data were collected from July to October 2009, focusing on 37 workers who attended eight weekly acupuncture sessions. The Pittsburgh Sleep Quality Index was used to assess their sleep quality before and after the intervention. Results show that before the intervention, five (13.5%) people experienced good quality of sleep whereas at the end of the study 14 (37.8%) showed this condition. Statistic significance (p=0.0001) was found in comparing the mean scores obtained before and after acupuncture. Acupuncture had effects on the quality of sleep in the studied sample, presenting itself as a complementary technique for treating sleep disorders and consequently improving the quality of life in this population.
Resumo:
In Brazil, during the XX century, dozens of Spiritist psychiatric hospitals emerged seeking to integrate conventional medical treatment with complementary spiritual therapy. This combined inpatient treatment is largely found in Brazil, where many psychiatric hospitals stem from the Spiritist movement. The present report describes the use of these spiritual practices, their operating structure, health professionals involved, modalities of care, and institutional difficulties in integrating spiritual practices with conventional treatment in six leading Brazilian Spiritist psychiatric hospitals. These hospitals combine conventional psychiatric treatment with voluntary-based spiritual approaches such as laying on of hands ("fluidotherapy"), lectures regarding spiritual and ethical issues, intercessory prayer, spirit release therapy ("disobsession") and "fraternal dialogue". The non-indoctrination and optional nature of these spiritual complementary therapies seem to increase acceptance among patients and their family members. In conclusion, the Spiritist psychiatric hospitals in Brazil have, for more than half a century, provided an integrative approach in the treatment of psychiatric disorders, associating conventional and spiritual treatments, more specifically Spiritist therapy. The lack of standardized treatment protocols and scientific studies remain a barrier to assessing the impact of this integrative approach on patients' mental health, quality of life, adherence, and perceived quality of treatment.
Resumo:
We present a new Ultra Wide Band (UWB) Timed- Array Transmitter System with Beamforming capability for high-resolution remote acquisition of vital signals. The system consists of four identical channels, where each is formed of a serial topology with three modules: programmable delay circuit (PDC or τ), a novel UWB 5th Gaussian Derivative order pulse generator circuit (PG), and a planar Vivaldi antenna. The circuit was designed using 0.18μm CMOS standard process and the planar antenna array was designed with filmconductor on Rogers RO3206 substrate. Spice simulations results showed the pulse generation with 104 mVpp amplitude and 500 ps width. The power consumption is 543 μW, and energy consumption 0.27 pJ per pulse using a 2V power supply at a pulse repetition rate (PRR) of 100 MHz. Electromagnetic simulations results, using CST Microwave (MW) Studio 2011, showed the main lobe radiation with a gain maximum of 13.2 dB, 35.5º x 36.7º angular width, and a beam steering between 17º and -11º for azimuthal (θ) angles and 17º and -18º for elevation (φ) angles at the center frequency of 6 GHz