2 resultados para Categorical data

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Categorical data cannot be interpolated directly because they are outcomes of discrete random variables. Thus, types of categorical variables are transformed into indicator functions that can be handled by interpolation methods. Interpolated indicator values are then backtransformed to the original types of categorical variables. However, aspects such as variability and uncertainty of interpolated values of categorical data have never been considered. In this paper we show that the interpolation variance can be used to map an uncertainty zone around boundaries between types of categorical variables. Moreover, it is shown that the interpolation variance is a component of the total variance of the categorical variables, as measured by the coefficient of unalikeability. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: The aim of the present study was to investigate the FHR parameters in term pregnancies complicated by asthma. Study design: prospective cross-sectional study performed between July 2008 and November 2009. Twenty-one singleton pregnancy between 36 and 40 weeks gestation with diagnosis of maternal asthma and no current use of oral corticosteroids were compared with 30 pregnancies without morbidities at the same gestational age. The computerized cardiotocography (System 8002, Sonicaid) was performed and 30 min analysis was studied. Statistical analysis included Student's t-test or Mann-Whitney U test for comparisons between groups. Categorical data were compared using the chi(2)-test or Fisher's exact test. Results: There were no significant differences in FHR parameters analyzed by computerized cardiotocography: basal FHR (p = 0.80), number of accelerations >10 bpm (p = 0.08) or >15 bpm (p = 0.20), duration of high episodes (p = 0.70), duration of low episodes (p = 0.46) and STV (p = 0.66). Asthmatic mothers presented mean number of fetal movement per hour significantly lower than control group (34.6 +/- 28.2 vs. 60.6 +/- 43.1, p = 0.02). Conclusion: Computerized cardiotocography demonstrates no association between the abnormal parameters of FHR and maternal asthma in term pregnancies. Maternal asthma was associated with less fetal movements per hour, suggesting further studies on the counting of fetal movements in pregnant women with asthma.