3 resultados para CO2 reduction

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Carbon supported Pt-Sn catalysts were prepared by reduction of Pt and Sn precursors with formic acid and characterized in terms of structure, morphology and surface properties. The electrocatalytic activity for ethanol oxidation was studied in a direct ethanol fuel cell (DEFC) at 70 degrees C and 90 degrees C. Electrochemical and physico-chemical data indicated that a proper balance of Pt and Sn species in the near surface region was necessary to maximize the reaction rate. The best atomic surface composition, in terms of electrochemical performance, was Pt:Sn 65:35 corresponding to a bulk composition 75:25 namely Pt3Sn1/C. The reaction products of ethanol electro-oxidation in single cell and their distribution as a function of the nature of catalyst were determined. Essentially, acetaldehyde and acetic acid were detected as the main reaction products; whereas, a lower content of CO2 was formed. The selectivity toward acetic acid vs. acetaldehyde increased with the increase of the Sn content and decreased by decreasing the concentration of the reducing agent used in the catalyst preparation. According to the recent literature, these results have been interpreted on the basis of ethanol adsorption characteristics and ligand effects occurring for Sn-rich electrocatalysts. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: Considering the enamel chemical structure, especially carbonate band, which has a major role in the caries prevention, the objective of the present study was to assess the chemical alterations on the enamel irradiated with CO2 laser by means of FTIR spectroscopy and SEM analysis. Design: The enamel surfaces were analysed on a spectrometer for acquisition of the absorption spectrum relative to the chemical composition of the control sample. The irradiation was conducted with a 10.6-mu m CO2 laser (0.55 W, 660 W/cm(2)). The carbonate absorption band at 1600-1291 cm(-1) as well as the water absorption band at 3793-2652 cm(-1) was measured in each sample after the irradiation. The water band was measured again 24-h after the irradiation. The band area of each chemical compound was delimited, the background was subtracted, and the area under each band was integrated. Each area was normalized by the phosphate band (1190-702 cm(-1)). Results: There was a statistically significant decrease (p < 0.05) in the water content after irradiation (control: 0.184 +/- 0.04; irradiated: 0.078 +/- 0.026), which increased again after rehydration (0.145 +/- 0.038). The carbonate/phosphate ratio was measured initially (0.112 +/- 0.029) and its reduction after irradiation indicated the carbonate loss (0.088 +/- 0.014) (p < 0.05). Conclusion: The 10.6-mu m CO2 laser irradiation diminishes the carbonate and water contents in the enamel after irradiation. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: The aim of this study was to screen CO2 laser (10.6 mu m) parameters to increase enamel resistance to a continuous-flow erosive challenge. Background data: A new clinical CO2 laser providing pulses of hundreds of microseconds, a range known to increase tooth acid-resistance, has been introduced in the market. Methods: Different laser parameters were tested in 12 groups (n = 20) with varying fluences from 0.1 to 0.9 J/cm(2), pulse durations from 80 to 400 mu s and repetition rates from 180 to 700 Hz. Non-lased samples (n = 30) served as controls. All samples were eroded by exposure to hydrochloric acid (pH 2.6) under continuous acid flow (60 mu L/min). Calcium and phosphate release into acid was monitored colorimetrically at 30 sec intervals up to 5 min and at 1 min intervals up to a total erosion time of 15 min. Scanning electron microscopic (SEM) analysis was performed in lased samples (n = 3). Data were statistically analysed by one-way ANOVA (p < 0.05) and Dunnett's post-hoc tests. Results: Calcium and phosphate release were significantly reduced by a maximum of 20% over time in samples irradiated with 0.4 J/cm(2) (200 mu s) at 450 Hz. Short-time reduction of calcium loss (<= 1.5 min) could be also achieved by irradiation with 0.7 J/cm(2) (300 mu s) at 200 and 300 Hz. Both parameters revealed surface modification. Conclusions: A set of CO2 laser parameters was found that could significantly reduce enamel mineral loss (20%) under in vitro erosive conditions. However, as all parameters also caused surface cracking, they are not recommended for clinical use.