8 resultados para Brazil, Pontes e Lacerda
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
Introduction: Culex flavivirus (CxFV) was first isolated in 2007 from Culex pipiens in Japan and then identified in several other countries. Characterization of the CxFV showed that all strains are related to the cell fusing agent virus. In this manuscript we report the first identification of CxFV in South America. Material and Methods: We have collected Culex sp. mosquitoes using BG-Sentinel traps and manual aspirators. They were pooled according to genus, species, sex and location. Viral RNA was extracted and multiplex nested PCR was performed to test the presence of Flavivirus. The positive samples were isolated in C6/36 cells and sequenced for phylogenetic analyses. Results: 265 female Culex mosquitoes pooled in 83 pools were tested with specific CxFV, Saint Louis encephalitis virus (SLEV) and West Nile virus (WNV) primers. Our sequence data indicated maximum sequence similarity of 97% with CxFV. Discussion: In this study we report the circulation of CxFV in an urban setting where SLEV had previously caused an outbreak. In terms of public health, this is an important finding due to the assumption that the previous exposition of mosquitoes to CxFV might lessen the susceptibility of these mosquitoes to other flaviviruses. Copyright (C) 2012 S. Karger AG, Basel
Resumo:
Viruses are the major cause of lower respiratory tract infections in childhood and the main viruses involved are Human Respiratory Syncytial Virus (HRSV), Human Metapneumovirus (HMPV), Influenzavirus A and B (FLUA and FLUB), Human Parainfluenza Virus 1, 2 and 3 (HPIV1, 2 and 3) and Human Rhinovirus (HRV). The purposes of this study were to detect respiratory viruses in hospitalized children younger than six years and identify the influence of temperature and relative air humidity on the detected viruses. Samples of nasopharyngeal washes were collected from hospitalized children between May/2004 and September/2005. Methods of viral detection were RT-PCR, PCR and HRV amplicons were confirmed by hybridization. Results showed 54% (148/272) of viral positivity. HRSV was detected in 29% (79/272) of the samples; HRV in 23.1% (63/272); HPIV3 in 5.1% (14/272); HMPV in 3.3% (9/272); HPIV1 in 2.9% (8/272); FLUB in 1.4% (4/272), FLUA in 1.1% (3/272), and HPIV2 in 0.3% (1/272). The highest detection rates occurred mainly in the spring 2004 and in the autumn 2005. It was observed that viral respiratory infections tend to increase as the relative air humidity decreases, showing significant association with monthly averages of minimal temperature and minimal relative air humidity. In conclusion, viral respiratory infections vary according to temperature and relative air humidity and viral respiratory infections present major incidences it coldest and driest periods.
Resumo:
Integrative review of Brazilian studies about evidence-based practices (EBP) about prevention in human health, published in Web of Science/JCR journals, between October 2010 and April 2011. The aim was to identify the specialties that most accomplished these studies, their foci and methodological approaches. Based on inclusion criteria, 84 studies were selected, mainly published in public health journals, focusing on primary care and also addressing clinical issues and different specialties. Prevention foci and methodological approaches also varied, with a predominance of systematic reviews without meta-analysis. The results indicate that there is no single way to conceptualize and practice EBP in the field of prevention, and that its application may not only serve to obtain indisputable evidence to equip intervention actions. This endless knowledge area is under construction, with a view to the analysis and further understanding of health phenomena.
Resumo:
The NNW-trending Nova Lacerda tholeiitic dike swarm in Mato Grosso State, Central Brazil, intrudes the Nova Lacerda granite (1.46 Ga) and the Jauru granite-greenstone terrain (ca. 1.79-1.77 Ga). The swarm comprises diabases I and II and amphibolites emplaced at ca. 1.38 Ga. Geochemical data indicate that these are evolved tholeiites characterized by high LILE/HSFE and LREE/HSFE ratios. Isotopic modelling yields positive epsilon(Nd)(T) values (+0.86 to +2.65), whereas values for epsilon(Sr)(T) range from positive to negative (+1.96 to -5.56). Crustal contamination did not play a significant petrogenetic role, as indicated by a comparison of isotopic data (Sr-Nd) from both dikes and country rocks, and by the relationship between isotopic and geochemical parameters (SiO2, K2O, Rb/Sr, and La/Yb) of the dikes. We attribute the origin of these tholeiites to fractional crystallization of evolved melts derived from a heterogeneous mantle source. Comparison of the geochemical and isotopic data of the studied swarm and other tholeiitic Mesoproterozoic mafic intrusions of the SWAmazonian Craton the Serra da Providencia, Colorado, and Nova Brasilandia bimodal suites - indicates that parental melts of the Nova Lacerda swarm were derived from the most enriched mantle source. This enrichment was probably caused by the stronger influence of the EMI component on the DMM end-member. These data, coupled with trace element bulk-rock geochemistry of the country rocks, and comparisons with the Colorado Complex of similar age, suggest a continental-margin arc setting for the emplacement of the Nova Lacerda dikes.
Resumo:
Abstract Background Leptospirosis is a zoonosis which is spread through contamined running water. This contaminations is seriously affected by the flooding which occurs in the area surrounding the Aricanduva river. The transmission of the disease results mainly from the contact of water with soil contaminated by the urine of infected animals. We aimed to conduct an epidemiological survey on Leptospirosis cases in Sao Paulo East Zone area. Method The analysis conducted in this study was based on data collected from the health authorities of that region close the Aricanduva river between 2007 and 2008 years, which give the rates of confirmed cases, mortality and death from human Leptospirosis. Other information concerned with the relationships among rainfall index, points of flooding and incidence of Leptospirosis. Results We observed a direct and important water contamination. Records of flooding points and dates of the reported cases in the region showed a direct relationship from which the period of higher rainfall also recorded an increase in cases. The annual record of the city and the region and rainfall regions also presented correlation. Conclusion The association between the indices of flooding and Leptospirosis cases indicates that preventive measures are necessary to avoid exposing the community.
Resumo:
Viruses are the major cause of lower respiratory tract infections in childhood and the main viruses involved are Human Respiratory Syncytial Virus (HRSV), Human Metapneumovirus (HMPV), Influenzavirus A and B (FLUA and FLUB), Human Parainfluenza Virus 1, 2 and 3 (HPIV1, 2 and 3) and Human Rhinovirus (HRV). The purposes of this study were to detect respiratory viruses in hospitalized children younger than six years and identify the influence of temperature and relative air humidity on the detected viruses. Samples of nasopharyngeal washes were collected from hospitalized children between May/2004 and September/2005. Methods of viral detection were RT-PCR, PCR and HRV amplicons were confirmed by hybridization. Results showed 54% (148/272) of viral positivity. HRSV was detected in 29% (79/272) of the samples; HRV in 23.1% (63/272); HPIV3 in 5.1% (14/272); HMPV in 3.3% (9/272); HPIV1 in 2.9% (8/272); FLUB in 1.4% (4/272), FLUA in 1.1% (3/272), and HPIV2 in 0.3% (1/272). The highest detection rates occurred mainly in the spring 2004 and in the autumn 2005. It was observed that viral respiratory infections tend to increase as the relative air humidity decreases, showing significant association with monthly averages of minimal temperature and minimal relative air humidity. In conclusion, viral respiratory infections vary according to temperature and relative air humidity and viral respiratory infections present major incidences it coldest and driest periods.
Resumo:
The Light Steel Framing building technology was introduced in Brazil in the late 1990s for the construction of residential houses. Because the design system was imported from the United States and is optimised to work well in that temperate climate, some modi fi cations must be made to adapt it for the Brazilian climate. The objective of this paper was to assess the impact of thermal bridging across enclosure elements on the thermal performance of buildings designed with Light Steel Framing in Brazil. The numerical simulation program EnergyPlus and a speci fi c method that considered the effects of metallic structures in the hourly simulations were used for the analysis. Two air-conditioned commercial buildings were used as case studies. The peak thermal load increased approximately 10% when an interior metal frame was included in the numerical simulations compared to non-metallic structures. Even when a metal frame panel was used only for vertical elements in the facade of a building with a conventional concrete structure, the simulations showed a 5% increase in annual energy use.