8 resultados para BISMUTH IODIDES
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
The aim of the study was to determine if the increase in radiopacity provided by bismuth oxide is related to the color alteration of calcium silicate-based cement. Calcium silicate cement (CSC) was mixed with 0%, 15%, 20%, 30% and 50% of bismuth oxide (BO), determined by weight. Mineral trioxide aggregate (MTA) was the control group. The radiopacity test was performed according to ISO 6876/2001. The color was evaluated using the CIE system. The assessments were performed after 24 hours, 7 and 30 days of setting time, using a spectrophotometer to obtain the ΔE, Δa, Δb and ΔL values. The statistical analyses were performed using the Kruskal-Wallis/Dunn and ANOVA/ Tukey tests (p < 0.05). The cements in which bismuth oxide was added showed radiopacity corresponding to the ISO recommendations ( > 3 mm equivalent of Al). The MTA group was statistically similar to the CSC / 30% BO group (p > 0.05). In regard to color, the increase of bismuth oxide resulted in a decrease in the ΔE value of the calcium silicate cement. The CSC group presented statistically higher ΔE values than the CSC / 50% BO group (p < 0.05). The comparison between 24 hours and 7 days showed higher ΔE for the MTA group, with statistical differences for the CSC / 15% BO and CSC / 50% BO groups (p < 0.05). After 30 days, CSC showed statistically higher ΔE values than CSC / 30% BO and CSC / 50% BO (p < 0.05). In conclusion, the increase in radiopacity provided by bismuth oxide has no relation to the color alteration of calcium silicate-based cements.
Resumo:
Bi3.25La0.75-xErxTi3O12 and Bi3.25La0.75Ti3-xErxO12-delta ceramics were prepared and studied in this work in terms of dopant-induced phase and microstructure development as well as dielectric response. The results show that introduction of Er3+ tends to reduce the materials' sintering temperature and average grain size. Moreover, it was noted that in these systems the substitution site of this dopant is controlled by valence state and ionic radii mismatch effects. In particular, even when a nominal substitution of Ti4+ is conceived, here it is found that Er3+ also incorporates at the (Bi,La)(3+) sites. These and other interesting concluding remarks from this work, including Er3+ tolerance, were possible only after comparing, especially, the X-ray diffraction results and the intrinsic ferroelectric characteristics extracted from the dielectric measurements. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
Introduction: The aim of this study was to evaluate the pH, calcium ion release, setting time, and solubility of white mineral trioxide aggregate (WMTA) and white Portland cement (WPC) combined with the following radiopacifying agents: bismuth oxide (BO), calcium tungstate (CT), and zirconium oxide (ZO). Methods: Fifty acrylic teeth with root-end filling material were immersed in ultrapure water for measurement of pH and calcium release (atomic absorption spectrophotometry) at 3, 24, 72, and 168 hours. For evaluation of setting time, each material was analyzed according to the American Society for Testing and Materials guidelines 266/08. The solubility test was performed according to American National Standards Institute/American Dental Association specification no. 57/2000. Solubility, setting time, and pH values were compared by using analysis of variance and Tukey test, and the values of calcium release were compared by the Kruskal-Wallis and Miller tests. The significance level was set at 5%. Results: The pH and calcium release were higher at 3 and 24 hours. WPC was the material with the higher values for both properties. WMTA had the greatest solubility among all materials (P < .05). All radiopacifiers increased the setting time of WPC, and WMTA had the shortest setting time among all materials (P < .05). Conclusions: All materials released calcium ions. Except for WPC/CT at 168 hours, all materials promoted an alkaline pH. On the basis of the obtained results, ZO and CT can be considered as potential radiopacifying agents to be used in combination with Portland cement. (J Endod 2012;38:394-397)
Resumo:
Electrochemical lead analyses of gunshot residues (GSRs) were performed using an acidic solution with a bare gold microelectrode in the presence of chloride ions. GSRs from four different guns (0.38 in. revolver, 12 caliber pump-action shotgun, 0.38 repeating rifle, and a 0.22 caliber semi-automatic rifle) and six different types of ammunition (CleanRange (R), normal, semi-jacketed, especial 24g (R), 3T (R), CBC (R), and Eley (R)) were analyzed. Results obtained with the proposed methodology were compared with those from an atomic absorption spectrometry analysis, and a paired Student's t-test indicated that there was no significant difference between them at the 95% confidence level. With this methodology, a detection limit of 1.7 nmol L-1 (3 sigma/slope), a linear range between 10 and 100 nmol L-1, and a relative standard deviation of 2.5% from 10 measurements were obtained. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
Estuarine systems play an important role in the retention of toxic trace elements owing to the affinity of these elements with particles dissolved in water. This work presents the use of a voltammetric sensor to monitor heavy metal (Zn (II), Cd(II) and Pb (II)) concentrations in the Cananeia-Iguape Estuarine-Lagoon region (Sao Paulo State, Brazil). Lower concentrations were found in the Southern estuarine system (Cananeia City) and increased concentrations observed in the Northern sector (Iguape City) were promoted by anthropogenic activities, with particular influence from the historical introduction of mining wastes and inputs from agricultural, industrial and domestic effluents. The proposed method is reliable, inexpensive and fast, can simultaneously provide information on the concentration of these metallic ions and can be easily used for field measurements aboard oceanographic ships.
Resumo:
The enantioselective carbon-boron bond oxidation of several chiral boron-containing compounds by Baeyer-Villiger monooxygenases was evaluated. PAMO and M446G PAMO conveniently oxidized 1-phenylethyl boronate into the corresponding 1-(phenyl)ethanol (ee = 82-91%). Cyclopropyl boronic esters were also oxidized but with no enantioselectivity. beta-Boryl carboxylic esters were not oxidized by any BVMOs. (C) 2012 Elsevier Ltd. All rights reserved.
Resumo:
The influence of chloride on the electrodeposition of lead films and their dissolution in anodic stripping voltammetric experiments was examined. Gold substrates were plated with lead films, and mass changes were monitored by using the electrochemical quartz crystal microbalance with dissipation factor (EQCM-D). The results showed that the amount of electrodeposited lead is slightly dependent on the chloride concentration. The charge/mass ratio data indicated the presence of Pb(I) and Pb(II) as a result of film dissolution, and the precipitation and deposition of PbCl2 onto the electrode surface. Scanning electron microscopy images revealed that the morphology of the lead film was strongly influenced by chloride present in the plating solution and that much rougher films were obtained in comparison with those obtained in the absence of chloride. The rate of the anodic dissolution was higher for lead films with higher surface areas, which lead to an increase in their stripping voltammetric currents. (C) 2012 Elsevier Ltd. All rights reserved.
Resumo:
The aim of this study was to evaluate the interference of the radiopacifiers bismuth oxide (BO), bismuth carbonate (BC), bismuth subnitrate (BS), and zirconiun oxide (ZO) on the solubility, alkalinity and antimicrobial properties of white Portland cement (WPC). The substances were incorporated to PC, at a ratio of 1:4 (v/v) and subjected to a solubility test. To evaluate the pH, the cements were inserted into retrograde cavities prepared in simulated acrylic teeth and immediately immersed in deionized water. The pH of the solution was measured at 3, 24, 72 and 168 h. The antimicrobial activity was evaluated by a radial diffusion method against the microorganisms S. aureus (ATCC 25923), P. aeruginosa (ATCC 27853), E. faecalis (ATCC 29212) and C. albicans (ATCC 10231). The zone of microbial growth inhibition was measured after 24 h. The addition of BS and BC increased the solubility of the cement. The pH values demonstrated that all materials produced alkaline levels. At 3 h, BS showed lower pH than WPC (p<0.05). At 168 h, all materials showed similar pHs (p>0.05). The materials did not present antimicrobial activity for S. aureus, P. aeruginosas and E. faecalis (p>0.05). With regards to C. albicans, all materials formed an inhibition zone, mainly the mixture of WPC with ZO (p<0.05). The type of radiopacifier incorporated into WPC interfered with its physical and antimicrobial properties. ZO was found to be a viable radiopacifier that can be used with WPC.