4 resultados para Atomic Displacement Parameters

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The influence of deposition parameters, namely polymer concentration and pH of the deposition solution, cleaning, and drying steps on the morphology and electrical characteristics of polyaniline and sulfonated polystyrene (PANI/PSS) nanostructured films deposited by the self-assembly technique is evaluated by UV-Vis spectroscopy, optical and atomic force microscopy, and electrical resistance measurements. It is found that stirring the cleaning solution during the cleaning step is crucial for obtaining homogenous films. Stirring of the cleaning solution also influences the amount of PANI adsorbed in the films. In this regard, the drying process seems to be less critical since PANI amount and film thickness are similar in films dried with N-2 flow or with an absorbent tissue. It is observed, however, that drying with N-2 flow results in rougher films. As an additional point, an assessment of the influence of the deposition method (manual versus mechanical) on the film characteristics was carried out. A significant difference on the amount of PANI and film thickness between films prepared by different human operators and by a homemade mechanical device was observed. The variability in film thickness and PANI adsorbed amount is smaller in films mechanically assembled. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Since the mid 1980s the Atomic Force Microscope is one the most powerful tools to perform surface investigation, and since 1995 Non-Contact AFM achieved true atomic resolution. The Frequency-Modulated Atomic Force Microscope (FM-AFM) operates in the dynamic mode, which means that the control system of the FM-AFM must force the micro-cantilever to oscillate with constant amplitude and frequency. However, tip-sample interaction forces cause modulations in the microcantilever motion. A Phase-Locked loop (PLL) is used to demodulate the tip-sample interaction forces from the microcantilever motion. The demodulated signal is used as the feedback signal to the control system, and to generate both topographic and dissipation images. As a consequence, a proper design of the PLL is vital to the FM-AFM performance. In this work, using bifurcation analysis, the lock-in range of the PLL is determined as a function of the frequency shift (Q) of the microcantilever and of the other design parameters, providing a technique to properly design the PLL in the FM-AFM system. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Despite the quantum nature of the process, collective scattering by dense cold samples of two-level atoms can be interpreted classically describing the sample as a macroscopic object with a complex refractive index. We demonstrate that resonances in Mie theory can be easily observable in the cooperative scattering by tuning the frequency of the incident laser field or the atomic number. The solution of the scattering problem is obtained for spherical atomic clouds who have the parabolic density characteristic of BECs, and the cooperative radiation pressure force calculated exhibits resonances in the cloud displacement for dense clouds. At odds with uniform clouds which show a complex structure including narrow peaks, these densities show resonances, yet only under the form of quite regular and contrasted oscillations. Copyright (C) EPLA, 2012

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: To compare stabilometric parameters of elderly female fallers and non-fallers associated or not with knee osteoarthritis (OA). Methods: Fifty-six elderly female fallers and non-fallers diagnosed or not with unilateral or bilateral knee OA were divided into the following groups: FOA (n = 10), elderly female falters with knee OA; FNOA (n = 11), elderly female fallers without knee OA; NFOA (n = 14), elderly female non-fallers with knee OA; and NFNOA (n = 21), elderly female non-fallers without knee OA. For analyzing semi-static balance on a force platform with the elderly females standing, the following parameters were assessed in four conditions: center of pressure (COP), anterior-posterior and mediolateral displacements (APD and MLD, respectively); and COP anterior-posterior and mediolateral displacement velocities (APV and MLV, respectively). The following conditions were assessed: 1) standing on a firm wooden surface with eyes open (WSEO); 2) standing on a firm wooden surface with eyes closed (WSEC); 3) standing on a foam surface with eyes open (FSEO); 4) standing on a foam surface with eyes closed (FSEC). Results: The elderly females with knee OA showed greater APD in all four conditions assessed (P < 0.05), while the elderly female fallers showed greater MLD (P < 0.05). No difference between the groups was observed for APV and MLV (P > 0.05). Conclusions: Knee OA per se increases APD of the COP, while the history of falls, regardless of the presence of knee OA, hinders postural control in the ML direction.