3 resultados para Arm

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study compared the arm regeneration frequencies in two different populations of Ophionereis reticulata (Say, 1825) in Sao Sebastiao, Southeast Brazil and observed arm regeneration between age classes (juvenile and adults) and sexes (male and female). From the 1,170 individuals sampled, 1,089 (92.2%) showed signs of arm regeneration. The relative frequencies of regenerating arms in the two areas were not different (Baleeiro Isthmus: 91.3% and Grande Beach: 99.5%). Both areas also presented similar values for the number of arms regenerating/individual and in the frequency of regenerating individuals. The major part of the regenerating scars was concentrated in the distal portion of the arm. Sub-lethal predation is most likely the cause to the high rates of arm regeneration in O. reticulata. There was no significant differences in the regeneration rates between females (3.57 +/- 1.36 arms regenerating/individual) and males (3.47 +/- 1.42).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Evaluation of the antimicrobial effect of skin disinfection techniques is essential to avoid the transmission of infectious agents during blood transfusion. The aim of this study was to examine the effectiveness of two methods of arm skin disinfection used in blood donors at a Hemotherapy Center in Brazil that represents an important centre for distributing haemocomponents to many cities in the country. Methods: Two skin disinfection techniques in 50 blood donors were evaluated. For the first arm, 10% povidone-iodine/two-stage technique was used. On the opposite arm, 0.5% chlorhexidine digluconate alcohol solution/one-stage technique was used. The swabs were seeded on three culture media: blood agar, mannitol salt agar and Mac Conkey agar. Automated bacterial classification based on biochemical tests/specific substrates was performed. Donor characteristics were collected using the computerised system of the Hemotherapy Center. Results: We found that microbial reduction was significantly higher for 10% povidone-iodine technique (98.57-98.87%) when compared with 0.5% chlorhexidine technique (94.38-95.06%). The species Leuconostoc mesenteroides and Staphylococcus hominis showed resistance to both disinfection techniques. We did not find statistically significant relationships between donor characteristics and microbial reduction. Conclusions: Arm skin disinfection with 10% povidone-iodine produced better antimicrobial activity. We must acknowledge that 10% povidone-iodine technique has the limitation of being a two-stage method. However, prevention of adverse events due to bacterial contamination and transfusion reactions should be prioritised. Production of hypoallergenic and stronger antiseptics that allowed a safe one-stage disinfection technique should be encouraged in health systems, not only in Brazil but also around the world.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Insertion of totally implantable catheters via deep vessels that drain into the superior vena cava results in a lower incidence of venous thrombosis and infection as compared to catheters inserted into femoral and arm veins. Superior vena cava obstruction and inadequacy of the thoracic wall are conditions that prevent reservoir implantation in the chest wall. In this article, we describe a technical innovation that enables the pocket to be fixed in the arm while still allowing access to be achieved via the internal jugular vein. Method: The procedure reported maintains the use of the internal jugular vein for access even when the patient's chest is not suited for reservoir implantation, which is localized in the arm. Results: The procedure was successful and no complications occurred. The position of the catheter tip did not alter with arm movement. Conclusion: The implantation of a port reservoir in the arm following venous access via the internal jugular vein is both safe and convenient.