10 resultados para Angle of air injection

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

100.00% 100.00%

Publicador:

Resumo:

To evaluate an innovative technique for intrastromal air injection to achieve deep anterior lamellar keratoplasty (DALK) with bare Descemet membrane (DM). Thirty-four eyes with anterior corneal pathology, including 27 with keratoconus, underwent DALK. After 400 mm trephination with a suction trephine, ultrasound pachymetry was performed 0.8 mm internally from the trephination groove in the 11 to 1 o'clock position. In this area, a 2-mm incision was created, parallel to the groove, with a micrometer diamond knife calibrated to 90% depth of the thinnest measurement. A cannula was inserted through the incision and 0.5 mL of air was injected to dissect the DM from the stroma. After peripheral paracentesis, anterior keratectomy was carried out to bare the DM. A 0.25-mm oversized graft was sutured in place. Overall, 94.1% of eyes achieved DALK. Bare DM was achieved in 30 eyes, and a pre-DM dissection was performed in 2 eyes. Air injection was successful in detaching the DM (achieving the big bubble) in 88.2% of the eyes. In keratoconus eyes, the rate was 88.9%. All cases but one required a single air injection to achieve DM detachment. Microperforations occurred in 5 cases: 3 during manual layer-by-layer dissection after air injection failed to detach the DM, 1 during removal of the residual stroma after big-bubble formation, and 1 during the diamond knife incision. Two cases (5.9%) were converted to penetrating keratoplasty because of macroperforations. The technique was reproducible, safe, and highly effective in promoting DALK with bare DM.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Even though air pollutants exposure is associated with changes in the ocular surface and tear film, its relationship to the clinical course of blepharitis, a common eyelid disease, had not yet been investigated. Our objective was to investigate the correlation between air pollution and acute manifestations of blepharitis. Method: We recorded all cases of changes in the eyelids and ocular surface, and rated clinical findings on a scale from zero (normal) to two (severe alterations). Daily values of carbon monoxide, particulate matter smaller than 10 mu m in diameter and nitrogen dioxide concentrations and meteorological variables (temperature and relative humidity) in the vicinity of the medical service were obtained. Specific linear regression models for each outcome were constructed including pollutants as independent variables (single pollutant models). Temperature and humidity were included as confounding variables. Results: increases of 28.8 mu g/m(3) in the concentration of particulate matter and 1.1 ppm in the concentration of CO were associated with increases in cases of blepharitis on the day of exposure (5 cases, 95% CI: 1-10 and 6 cases, 95% CI: 1-12, respectively). Conclusion: Exposure to usual air pollutants concentrations present in large cities affects, in a consistent manner, the eyes of residents contributing to the increasing incidence of diseases of the eyelid margin. (C) 2011 Elsevier Inc. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this research was to evaluate economic costs of respiratory and circulatory diseases in the municipality of Cubatao, in the state of Sao Paulo, Brazil. Data on hospital admissions and on missed working days due to hospitalization (for age group 14 to 70 years old) from the database of Sistema Unico de Sa de (SUS - Brazilian National Health System) were used. Results: Based on these data, it was calculated that R$ 22.1 million were spent in the period 2000 to 2009 due to diseases of the respiratory and circulatory systems. Part of these expenses can be directly related to the emission of atmospheric pollutants in the city. In order to estimate the costs related to air pollution, data on Cubatao were compared to data from two other municipalities that are also located at the coast side (Guaruja and Peru be), but which have little industrial activity in comparison to Cubatao. It was verified that, in both, average per capita costs were lower when compared to Cubatao, but that this difference has been decreasing in recent years.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: This study evaluated the variations in the anterior cranial base (S-N), posterior cranial base (S-Ba) and deflection of the cranial base (SNBa) among three different facial patterns (Pattern I, II and III). Method: A sample of 60 lateral cephalometric radiographs of Brazilian Caucasian patients, both genders, between 8 and 17 years of age was selected. The sample was divided into 3 groups (Pattern I, II and III) of 20 individuals each. The inclusion criteria for each group were the ANB angle, Wits appraisal and the facial profile angle (G’.Sn.Pg’). To compare the mean values obtained from (SNBa, S-N, S-Ba) each group measures, the ANOVA test and Scheffé’s Post-Hoc test were applied. Results and Conclusions: There was no statistically significant difference for the deflection angle of the cranial base among the different facial patterns (Patterns I, II and III). There was no significant difference for the measures of the anterior and posterior cranial base between the facial Patterns I and II. The mean values for S-Ba were lower in facial Pattern III with statistically significant difference. The mean values of S-N in the facial Pattern III were also reduced, but without showing statistically significant difference. This trend of lower values in the cranial base measurements would explain the maxillary deficiency and/or mandibular prognathism features that characterize the facial Pattern III.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To investigate macular thickness and visual acuity changes after 1 intravitreal injection of 0.5-mg ranibizumab during phacoemulsification cataract surgery in eyes with diabetic macular edema refractory to laser treatment. Methods: Eleven eyes of 11 patients with diabetic macular edema refractory to modified Early Treatment Diabetic Retinopathy Study laser therapy received intravitreal during phacoemulsification cataract surgery. Comprehensive ophthalmic evaluation was performed preoperatively and at 1, 4, 8 +/- 1, and 12 +/- 2 weeks postoperatively. Main outcome measures included central subfield thickness and best-corrected Early Treatment Diabetic Retinopathy Study visual acuity. Results: Eleven patients completed the 12-week study visit. Mean central subfield thickness (+/- SEM) was 399.82 +/- 29.50 mu m at baseline and did not change significantly at any postoperative study visit (P > 0.05). Mean (+/- SEM) best-corrected Early Treatment Diabetic Retinopathy Study visual acuity was 0.95 +/- 0.13 logarithm of the minimum angle of resolution (20/200) at baseline and was significantly improved at Weeks 1 (0.38 +/- 0.13), 4 (0.38 +/- 0.11), 8 (0.35 +/- 0.08), and 12 (0.46 +/- 0.12) after treatment (P < 0.05). Conclusion: In this case series of patients with diabetic macular edema refractory to laser therapy, intravitreal ranibizumab administered during cataract surgery was associated with no significant change in central subfield thickness postoperatively. Significant improvement in best-corrected Early Treatment Diabetic Retinopathy Study visual acuity was observed after treatment, likely because of cataract removal. RETINA 32:1799-1803, 2012

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We evaluated the effects of air-drying distance and bond surface area on the shear bond strength of a 2-step etch-and-rinse adhesive. A total of 120 bovine anterior teeth were equally divided into 6 main groups based on bonding surface area. The main groups were divided into sub-groups (n = 5) according to air-drying distance. The shear strength was determined using a universal testing machine at a crosshead speed of 0.5 mm/min. The averaged results were subjected to two-way ANOVA and Tukey's test (alpha = 0.05). Two-way ANOVA testing identified no significant cross-product interactions (p > 0.05), but the main factors of area (p < 0.0001) and air-drying distance (p < 0.00001) significantly affected the mean bond strength. Shorter air-drying distances improved bond strength, and increased surface area decreased the bond strength.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective Epidermoid cysts of the cerebellopontine angle (CPA) can be a surgical challenge for the pediatric neurosurgeon. Ideally, total removal must be achieved; however, occasional adhesions of these tumors to vital neurovascular structures and extension far beyond the midline may preclude their total removal. The aims of this article are to present an alternative surgical approach to these lesions and to provide the rationale for this technique. Material and methods A 16-year-old boy was admitted to our pediatric neurosurgery department with a 1-year history of nonspecific headaches. His neurological examination showed right-sided dysmetria and gait ataxia. Magnetic resonance scans showed a space-occupying lesion on the right CPA with low intensity on T-1-weighted images and high intensity on T-2-weighted images. Results Craniotomy for tumor excision via pre- and subtemporal transtentorial approach was performed disclosing a 3.5 x 3 x 2.8-cm(3) well-encapsulated tumor, which was confirmed to be an epidermoid cyst. The postoperative course was uneventful. Conclusions A combined pre- and subtemporal approach utilizes a wide opening of the tentorium and the option of supratentorial retraction of the cerebellum to provide an excellent angle of approach to CPA lesions involving the anterolateral aspect of the brain stem in children.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Sensor and actuator based on laminated piezocomposite shells have shown increasing demand in the field of smart structures. The distribution of piezoelectric material within material layers affects the performance of these structures; therefore, its amount, shape, size, placement, and polarization should be simultaneously considered in an optimization problem. In addition, previous works suggest the concept of laminated piezocomposite structure that includes fiber-reinforced composite layer can increase the performance of these piezoelectric transducers; however, the design optimization of these devices has not been fully explored yet. Thus, this work aims the development of a methodology using topology optimization techniques for static design of laminated piezocomposite shell structures by considering the optimization of piezoelectric material and polarization distributions together with the optimization of the fiber angle of the composite orthotropic layers, which is free to assume different values along the same composite layer. The finite element model is based on the laminated piezoelectric shell theory, using the degenerate three-dimensional solid approach and first-order shell theory kinematics that accounts for the transverse shear deformation and rotary inertia effects. The topology optimization formulation is implemented by combining the piezoelectric material with penalization and polarization model and the discrete material optimization, where the design variables describe the amount of piezoelectric material and polarization sign at each finite element, with the fiber angles, respectively. Three different objective functions are formulated for the design of actuators, sensors, and energy harvesters. Results of laminated piezocomposite shell transducers are presented to illustrate the method. Copyright (C) 2012 John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives/Hypothesis. Hepatocyte growth factor (HGF) is a multifunctional polypeptide that plays various roles in embryogenesis and tissue regeneration and exhibits marked antifibrotic activity. The present study sought to assess the effects of HGF injection and reinjection coinciding with its peak of activity on collagen density, vessel density, inflammatory reaction in the lamina propria, and mean epithelial thickness in the injured rabbit vocal fold. Study Design. Prospective, controlled, experimental animal study. Methods. Fourteen rabbits were subdivided into two groups and underwent injury of the vocal folds. Immediately after injury, animals in group 1 received HGF injections into the right vocal fold (RVF), whereas those in group 2 received bilateral HGF injections and a single reinjection into the RVF 10 days after the first, to coincide with the peak of HGF activity. The left vocal folds (LVFs) served as controls in both groups. Histological assessment of laryngeal specimens was performed at 30 and 40 days, respectively. Results. In both groups, collagen density was lower in the right (treated) vocal folds than in the left (control) folds (P = 0.018). Vessel density was higher in the RVFs in group 2 (P = 0.018). Differences were found in mean epithelial thickness and inflammatory reaction in the lamina propria but did not reach statistical significance. Conclusions. In the scarred rabbit vocal fold, HGF injection is associated with decreased collagen density in the lamina propria, whereas reinjection after 10 days produces decreased collagen density and higher vessel density.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work presents the results from the development of bio-cathodes for the application on paper-based biofuel cells. Our main goal here is to demonstrate the possibility of using different designs of air-breathing bio-cathodes and ink-based bio-cathodes for this new type of paper based electrochemical cell. The electrochemical performance for the bio-electrocatalytic oxygen reduction reaction was studied by using open circuit voltage and amperometry measurements, as well as polarization curves to probe the four-electron reduction reaction of ambient oxygen catalyzed by bilirubin oxidase (BOx). The electrochemical measurements showed that all procedures allowed the direct electron transfer from the active site of the bilirubin oxidase to the electrode surface with a limiting current density of almost 500 mu A cm(-2) for an air-breathing BOx cathode and 150 mu A cm(-2) for an ink based BOx cathode. Under a load of 300 mV a stable current density was obtained for 12 h of continuous operation. (C) 2012 Elsevier Ltd. All rights reserved.