12 resultados para Anchorage.

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The aims of this meta-analysis were to quantify and to compare the amounts of distalization and anchorage loss of conventional and skeletal anchorage methods in the correction of Class II malocclusion with intraoral distalizers. Methods: The literature was searched through 5 electronic databases, and inclusion criteria were applied. Articles that presented pretreatment and posttreatment cephalometric values were preferred. Quality assessments of the studies were performed. The averages and standard deviations of molar and premolar effects were extracted from the studies to perform a meta-analysis. Results: After applying the inclusion and exclusion criteria, 40 studies were included in the systematic review. After the quality analysis, 2 articles were classified as high quality, 27 as medium quality, and 11 as low quality. For the meta-analysis, 6 studies were included, and they showed average molar distalization amounts of 3.34 mm with conventional anchorage and 5.10 mm with skeletal anchorage. The meta-analysis of premolar movement showed estimates of combined effects of 2.30 mm (mesialization) in studies with conventional anchorage and 4.01 mm (distalization) in studies with skeletal anchorage. Conclusions: There was scientific evidence that both anchorage systems are effective for distalization; however, with skeletal anchorage, there was no anchorage loss when direct anchorage was used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: This retrospective cephalometric study analyzed the influence of intentional ankylosis of deciduous canines in patients with Class III malocclusion and anterior crossbite, in the deciduous and early mixed dentition stages, treated by orthopedic maxillary expansion followed by maxillary protraction. Methods: Lateral cephalograms of 40 patients were used, divided in 2 groups paired for age and gender. The Ankylosis Group was composed of 20 patients (10 boys and 10 girls) treated with induced ankylosis and presenting initial and final mean ages of 7 years 4 months and 8 years 3 months, respectively, with a mean period of maxillary protraction of 11 months. The Control Group comprised 20 patients (10 boys and 10 girls) treated without induced ankylosis, with initial and final mean ages of 7 years 8 months and 8 years 7 months, respectively, with a mean period of maxillary protraction of 11 months. Two-way analysis of variance and covariance analysis were applied to compare the initial and final cephalometric variables and the treatment changes between groups. Results: According to the results, the variables evidencing the significant treatment changes between groups confirmed that the intentional ankylosis enhanced the sagittal response of the apical bases (Pg-NPerp) and increased the facial convexity angles (NAP and ANB). Conclusions: The protocol involving intentional ankylosis of deciduous canines enhanced the sagittal response of the apical bases.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

During copulation, spermatophores produced by male coleoid cephalopods undergo the spermatophoric reaction, a complex process of evagination that culminates in the attachment of the spermatangium (everted spermatophore containing the sperm mass) on the female's body. To better understand this complicated phenomenon, the present study investigated the functional morphology of the spermatophore of the squid Doryteuthis plei applying in vitro analysis of the reaction, as well as light and electron microscopy investigation of spermatangia obtained either in vitro, or naturally attached on females. Hitherto unnoticed functional features of the loliginid spermatophore require a reappraisal of some important processes involved in the spermatophoric reaction. The most striking findings concern the attachment mechanism, which is not carried out solely by cement adhesive material, as previously believed, but rather by an autonomous, complex process performed by multiple structures during the spermatophoric reaction. During evagination, the ejaculatory apparatus provides anchorage on the targeted tissue, presumably due to the minute stellate particles present in the exposed spiral filament. Consequently, the ejaculatory apparatus maintains the attachment of the tip of the evaginating spermatophore until the cement body is extruded. Subsequently, the cement body passes through a complex structural rearrangement, which leads to the injection of both its viscid contents and pointed oral region onto the targeted tissue. The inner membrane at the oral region of the cement body contains numerous stellate particles attached at its inner side; eversion of this membrane exposes these sharp structures, which presumably adhere to the tissue and augment attachment. Several naturally attached spermatangia were found with their bases implanted at the deposition sites, and the possible mechanisms of perforation are discussed based on present evidence. The function of the complex squid spermatophore and its spermatophoric reaction is revisited in light of these findings. J. Morphol. 2012. (C) 2011 Wiley Periodicals, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Male coleoid cephalopods produce spermatophores that can attach autonomously on the female's body during a complex process of evagination called the spermatophoric reaction, during which the ejaculatory apparatus and spiral filament of the spermatophore are everted and exposed to the external milieu. In some deepwater cephalopods, the reaction leads to the intradermal implantation of the spermatophore, a hitherto enigmatic phenomenon. The present study builds upon several lines of evidence to propose that spermatophore implantation is probably achieved through the combination of (1) an evaginating-tube mechanism performed by the everting ejaculatory apparatus and (2) the anchorage provided by the spiral filament's stellate particles. The proposed theoretical model assumes that, as it is exposed to the external milieu, each whorl of the spiral filament anchors to the surrounding tissue by means of its sharp stellate particles. As the ejaculatory apparatus tip continues evaginating, it grows in diameter and stretches lengthwise, enlarging the diameter of the whorl and propelling it, consequently tearing and pushing the anchored tissue outward and backward, and opening space for the next whorl to attach. After the ejaculatory apparatus has been everted and has perforated tissue, the cement body is extruded, possibly aiding in final attachment, and the sperm mass comes to lie inside the female tissue, encompassed by the everted ejaculatory apparatus tube. It is proposed that this unique, efficient spermatophore attachment mechanism possibly evolved in intimate relationship with the adoption of an active mode of life by coleoids. The possible roles of predation pressure and sperm competition in the evolution of this mechanism are also discussed. (c) 2012 The Linnean Society of London, Biological Journal of the Linnean Society, 2012, 105, 711726.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

FALCAI MJ, LOUZADA MJQ, DE PAULA FJA, OKUBO R, VOLPON JB. A modified technique of rat tail suspension for longer periods of observation. Aviat Space Environ Med 2012; 83:1176-80. Background: Rat tail suspension is an accepted method to create experimental osteopenia. However, suspension periods longer than 3 wk may cause tail skin sloughing or rat slippage. The hypothesis was that a traction system with skeletal anchorage through one tail vertebra would prolong the suspension time without significant complications. Methods: There were 80 young adult female Wistar rats that were submitted to one of the following interventions: skeletal tail suspension (N = 20), skin tail suspension (N = 20), no intervention (N = 20), and a baseline control (N = 20). All animals were followed up either for 3 (N = 10) or 6 (N = 10) wk. Animals were assessed for clinical signs of stress and tolerance to suspension. The femur evaluation was in terms of mineral density content, mechanical resistance, and histomorphometry. Results/Discussion: All animals reached the 3-wk end point. However, for the 6-wk period, seven animals suspended by the skin traction method were discarded (70%) because of signs of stress and skin sloughing. In contrast, there was one loss in the skeletal suspension group (10%). All suspended animals developed similar osteopenia at 3 wk characterized by decreased bone mineral content, weakened bone resistance, and loss of femoral mass. At 6 wk, all suspended animals had similar osteopenic parameters, but they were not statistically different from those of the rats in the 3-wk groups. Therefore, suspension longer than 3 wk did not increase the bone deterioration in the femur.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mini-implant insertion requires accurate surgical technique. This study shows an insertion technique using only tooth crown references; its scientific basis is evaluated radiographically. The sample consisted of 213 inter-radicular septa, evaluated in 53 bitewing radiographs. The proximal contour of adjacent tooth crowns was used to define septum width. The midpoint of the septum width was linked to the interdental contact point to determine septum midline. The distances from septum midline to "mesial and distal teeth were measured to evaluate the septum midline centralization degree in two different septum heights. The difference between mesial and distal distances represented the septum midline deviation degree. The mesial and distal distances were compared by t-tests, and the septum midline deviation was correlated with septum height using Pearson's correlation test. The mesial and distal distances were not statistically different in the midpoint of the septum height, but they were different at the apical septum height. There was a moderate correlation (r = 0.45) between septum midline deviation and septum height. The tooth crown references evaluated on interproximal radiographs determine a high centralization degree of the septum midline on which the insertion site could be defined. The greater centralization degree was observed at the coronal septum area.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To verify if mini-implant mobility is affected by the presence of periodontopathogens, frequently associated with peri-implantitis. Materials and Methods: The surfaces of 31 mini-implants used for skeletal anchorage in orthodontic patients were evaluated. Polymerase chain reaction was used for identification of the presence of DNA from three different periodontopathogens (P. intermedia [Pi], A. actinomycetemcomitans [Aa], and P. gingivalis [Pg]) in 16 mini-implants without mobility (control group) and 15 mini-implants with mobility (experimental group). Results: The results showed that Pi was present in 100% of the samples, from both groups: Aa was found in 31.3% of the control group and in 13.3% of the experimental group. Pg was detected in 37.4% of the control group and in 33.3% of the experimental group. The Fisher exact test and the odds ratio (OR) values for Aa and Pg (OR = 0.34; 95% confidence interval [CI]: 0.05-2.10 and OR = 0.61; 95% Cl: 0.13-2.79, respectively) showed no significant association (P > .05) between the periodontopathogens studied and the mobility of the mini-implants. Conclusions: It can be concluded that the presence of Aa, Pi, and Pg around mini-implants is not associated with mobility. (Angle Orthod. 2012;82:591-595.)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose of this study was to evaluate the influence of miniscrew dental root proximity on its late stability degree. 40 miniscrews were inserted between maxillary second premolars and first molars for anterior retraction. Post-surgical radiographs were used to measure the septum width in the insertion site, insertion height, distal and mesial distance from miniscrew to dental root, and the smallest distance between miniscrew and dental root. The miniscrews were divided in two groups according to septum width: ?3 mm (20 miniscrews) and >3 mm (20 miniscrews). The soft tissue in the insertion site, sensitivity during load, plaque around the miniscrew, and evaluation period were also considered. The results showed no significant difference in miniscrew mobility degree and success rate between groups. Miniscrew dental root proximity did not influence the stability and success rate when the distance between the miniscrew and dental root indicated no periodontal ligament invasion. The overall success rate was 90% and no variable was associated with miniscrew failure. Nevertheless, patient sensitivity was frequently associated with some degree of mini-implant mobility. The septum width did not influence the stability and success rate of this anchorage system, but the extreme root proximity did.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The main objective of this paper was to discuss the importance of the reverse planning as guidance to surgical procedures on immediate loading implant-retained prosthesis, presenting a case report. Such design aims to define anchorage orientation after determination of prosthetic design. This is quite important because the possibility of success of cases with this kind of planning may achieve high levels of satisfaction. Another important aspect is the possibility of fast and definitive restoration of patients’ function and aesthetics

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to compare the effects of active and passive lacebacks on antero-posterior position of maxillary first molars and central incisors during leveling phase. Twenty-three subjects with Class I and Class II malocclusion were treated with first premolars extraction using preadjusted appliances (MBT 0.022-inch brackets). The leveling phase was performed with stainless steel archwires only. The sample was divided into 2 groups: 14 subjects received active lacebacks (Group 1) and 9 subjects received passive lacebacks (Group 2). Lacebacks were made from 0.008-inch ligature wire. Lateral cephalometric radiographs were taken pre- and post-leveling phase. Student's t-test was applied to determine the differences between pre- and post-leveling mean values and to determine the mean differences between groups. In Group I, the first molars showed a significant mesial movement, whereas no change was observed in Group 2. In both groups, maxillary central incisor crowns moved to lingual side. In conclusion, active laceback produced anchorage loss of maxillary first molars whereas passive laceback did not affect the position of these teeth. Active and passive lacebacks were effective in preventing central incisor proclination.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Avaliamos a influência do diâmetro e do modo de preparação do orifício piloto na resistência ao arrancamento e no torque de inserção dos parafusos pediculares com diâmetro interno cônico. MÉTODOS: Ensaios mecânicos foram realizados com parafusos pediculares com alma cônica e diâmetro de 4,2mm e 5,2mm inseridos nos pedículos vertebrais lombares de suínos. O orifício piloto foi confeccionado com de broca e sondas (pontiaguda e cortante) com diferentes diâmetros. RESULTADOS: Testando o parafuso de 4,2mm a perfuração com orifício igual ou inferior ao menor diâmetro interno do parafuso, aumentou o torque e a resistência ao arrancamento. Perfurações com diferentes instrumentos apresentaram comportamento semelhante. Perfurações com sondas permitiram que orifícios confeccionados com dimensões superiores ao menor diâmetro interno do parafuso apresentassem resistência semelhante a das perfurações com dimensões iguais ao menor diâmetro interno do implante, realizadas com sondas e brocas. CONCLUSÕES: Nos de 4,2 mm o diâmetro e o modo de preparação do orifício influenciam o torque e a resistência, nos de 5,2 mm apenas o torque de inserção. Não há correlação entre força de arrancamento e torque de inserção. Nível de evidência II, Estudos terapêuticos - Investigação dos Resultados do Tratamento.