2 resultados para Aminco-Bowman spectrofluorometer

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate biomechanical changes measured with the ORA (Ocular Response Analyzer (R); Reichert Ophthalmic Instruments, Buffalo, New York, USA) after Lasik with the Moria One Use Plus and to compare the biomechanics changes after myopic and hyperopic ablations. Methods: Fourteeneyes for hyperopia (H) and 19 eyes for myopia (M) were evaluated with the ORA preoperatively and 1 month after Lasik with thin flap (100 microns) using SBK-OUP (Sub-Bowman Keratomileusis-One Use Plus, Moria (R)). CH (Corneal Hysteresis), CRF (Corneal Resistance Factor), IOPg (gold-standard, Goldmann correlated Intraocular pressure), IOPcc (Corneal compensated Intraocular pressure) and more 38 variables derived from the corneal biomechanical response signal of the ORA were analyzed. The Wilcoxon test was used to assess differences between the variables before and after surgery for each group and the differences between the pre and postoperative (1 month) myopic eyes were compared with those obtained in hyperopic eyes, using the Mann-Whitney test. Results: There was a significant difference before and after Lasik in myopic and hyperopic eyes in IOPg (Wilcoxon, p<0.05), but not in IOPcc. Only myopic eyes showed a significant difference in CH and CRF measurements before and after LASIK, as well as 9 other biomechanical parameters (aspect1, h1, dive1, path1, p1area1, W11, H11, and w2 path11; Wilcoxon, p<0, 05), 8 of these being related to the first sign of flattening. Five parameters related to the sign of the second applanation showed significant variation only in the eyes before and after hyperopic Lasik (aspect2, h2, dive2, mslew2 and H21; Wilcoxon, p<0,05). There was a difference in both myopic and hyperopic on three parameters related to the applanation signal areas (p1area, and p2area p2area1; Wilcoxon, p<0.05). Differences in IOPg and p1area, before and after surgery were significantly higher in myopic eyes than in hyperopic eyes (Mann-Whitey, p<0.05). Conclusion: There are several significant differences in biomechanical parameters after Lasik with Moria OUP_SBK. Overall, the impact of myopic LASIK on corneal biomechanics is higher than of hyperopic Lasik. The parameters derived from the first sign of the ORA are more affected in myopic LASIK, whereas parameters derived from the second applanation are more affected in hyperopic LASIK.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A Distrofia Muscular de Duchenne (DMD) é uma miopatia severa de caráter recessivo ligada ao cromossomo X e o modelo animal de estudo mais relevante é o Golden Retriever Muscular Dystrophy (GRMD). Além das severas alterações que ocorrem na musculatura estriada, muitos estudos mostram que outras estruturas, inclusive viscerais, podem se mostrar alteradas nesta patologia. Desta forma, este trabalho objetivou análisar e comparar possíveis alterações estruturais e funcionais do rim em cães GRMD. Neste modelo de estudo, foi possível observar a presença das faces convexa e côncava, do hilo renal e dos pólos craniais e caudais dos rins. O órgão mostrou-se envolto por uma cápsula fibrosa. Em um corte sagital do órgão, notou-se a presença das regiões cortical e medular e da pelve renal. Na análise microscópica foi possível identificar a zona medular e cortical com suas estruturas: os corpúsculos renais formados pelo glomérulo e pela cápsula de Bowman, os túbulos contorcidos proximais e distais, os ductos coletores, vasos sanguíneos e os segmentos das Alças de Henle. As dosagens séricas de creatinina e uréia encontram-se dentro dos limites de normalidade. Desta forma, de acordo com os nossos resultados, podemos concluir que os animais afetados estudados, não apresentaram alterações estruturais ou funcionais dos rins, o que nos permitir sugerir que apesar da ingestão hídrica comprometida, a estrutura renal, mantem- se preservada nos animais GRMD.