2 resultados para Altos Hornos Zapla (Blast Furnace Zapla)

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chronic myelogenous leukemia (CML) is a common myeloproliferative disease that is characterized by the clonal expansion of marrow stem cells, and is associated with the Philadelphia chromosome. As the disease progresses, additional chromosome abnormalities may arise. The prognostic impact of secondary chromosomal abnormalities in CML is complex, heterogeneous, and sometimes related to previous treatment. Here, we describe a CML patient in lymphoid blast crisis associated with a new chromosomal abnormality identified, dic(7;12)(p12.21;p12.2) and i(12)(q10) using classical cytogenetics and spectral karyotype analysis. To the best of our knowledge, this is the first report of t(7;12)(p11.1;q11.1) and i(12)(q10) in a CML patient with lymphoid evolution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Determination of chlorine using the molecular absorption of aluminum mono-chloride (AlCl) at the 261.418 nm wavelength was accomplished by high-resolution continuum source molecular absorption spectrometry using a transversely heated graphite tube furnace with an integrated platform. For the analysis. 10 mu L of the sample followed by 10 mu L of a solution containing Al-Ag-Sr modifier, (1 g L-1 each), were directly injected onto the platform. A spectral interference due to the use of Al-Ag-Sr as mixed modifier was easily corrected by the least-squares algorithm present in the spectrometer software. The pyrolysis and vaporization temperatures were 500 degrees C and 2200 degrees C, respectively. To evaluate the feasibility of a simple procedure for the determination of chlorine in food samples present in our daily lives, two different digestion methods were applied, namely (A) an acid digestion method using HNO3 only at room temperature, and (B) a digestion method with Ag, HNO3 and H2O2, where chlorine is precipitated as a low-solubility salt (AgCl), which is then dissolved with ammonia solution. The experimental results obtained with method B were in good agreement with the certified values and demonstrated that the proposed method is more accurate than method A. This is because the formation of silver chloride prevented analyte losses by volatilization. The limit of detection (LOD, 3 sigma/s) for Cl in methods A and B was 18 mu g g(-1) and 9 mu g g(-1), respectively, 1.7 and 3.3 times lower compared to published work using inductively coupled plasma optical emission spectrometry, and absolute LODs were 2.4 and 1.2 ng, respectively. (C) 2012 Elsevier B.V. All rights reserved.