13 resultados para Acoustic attenuation
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
The practice of running has consistently increased worldwide, and with it, related lower limb injuries. The type of running surface has been associated with running injury etiology, in addition other factors, such as the relationship between the amount and intensity of training. There is still controversy in the literature regarding the biomechanical effects of different types of running surfaces on foot-floor interaction. The aim of this study was to investigate the influence of running on asphalt, concrete, natural grass, and rubber on in-shoe pressure patterns in adult recreational runners. Forty-seven adult recreational runners ran twice for 40 m on all four different surfaces at 12 +/- 5% km . h(-1). Peak pressure, pressure-time integral, and contact time were recorded by Pedar X insoles. Asphalt and concrete were similar for all plantar variables and pressure zones. Running on grass produced peak pressures 9.3% to 16.6% lower (P < 0.001) than the other surfaces in the rearfoot and 4.7% to 12.3% (P < 0.05) lower in the forefoot. The contact time on rubber was greater than on concrete for the rearfoot and midfoot. The behaviour of rubber was similar to that obtained for the rigid surfaces - concrete and asphalt - possibly because of its time of usage (five years). Running on natural grass attenuates in-shoe plantar pressures in recreational runners. If a runner controls the amount and intensity of practice, running on grass may reduce the total stress on the musculoskeletal system compared with the total musculoskeletal stress when running on more rigid surfaces, such as asphalt and concrete.
Resumo:
BACKGROUND: Because of their similar visual appearance, differentiation of left ventricular thrombotic material and myocardial wall can be difficult in contrast-enhanced coronary computed tomography (CT) angiography. OBJECTIVE: We identified typical thrombi attenuation of left ventricular thrombi with the use of CT measurement. METHODS: Over a time period of 6 years; we retrospectively identified 31 patients who showed a left ventricular thrombus in CT angiography datasets. Patients underwent routine contrast cardiac CT to investigate coronary artery disease. CT attenuation of each thrombus was assessed in the 4-chamber view. CT densities were also determined in the ascending aorta, left ventricle, and myocardial wall both in the mid-septal and mid-lateral segments. The mean CT attenuation of thrombi and the difference between attenuation in thrombi, left ventricular cavity, and myocardial wall were determined. The ratio of attenuation values in thrombus versus aorta and myocardium versus aorta were also determined. RESULTS: Mean (+/- SD) CT attenuation of all left ventricular thrombi in 31 patients was 43.2 +/- 15.3 HU (range, 25-80 HU). Mean CT densities of septal and lateral myocardial wall were 102.9 +/- 23.1 HU (range, 63-155 HU) and 99.3 +/- 28.7 HU (range, 72-191 HU), respectively, and were thus significantly higher than the CT attenuation of thrombi (P < 0.001). A threshold of 65 HU yielded a sensitivity, specificity, and positive and negative predictive values of 94%, 97%, 94%, and 97%, respectively, to differentiate thrombus from the myocardial wall. The mean ratio between CT attenuation of thrombus and CT attenuation within the ascending aorta was 0.11 +/- 0.05 (range, 0.04-0.23), which was significantly lower compared with the mean ratio between CT attenuation of the myocardial wall and the CT attenuation within the ascending aorta. CONCLUSION: CT attenuation within left ventricular thrombi was significantly lower than myocardial attenuation in CT angiography datasets. Assessment of CT attenuation may contribute to the differentiation of thrombi. (C) 2012 Society of Cardiovascular Computed Tomography. All rights reserved.
Resumo:
Objective: An experimental in vitro study was carried out to evaluate the influence of cortical bone thickness on ultrasound propagation velocity. Methods: Sixty bone plates were used, made from bovine femurs, with thickness ranging from 1 to 6 mm (10 of each). The ultrasound velocity measurements were performed using a device specially designed for this purpose, in an underwater acoustic tank and with direct contact using contact gel. The transducers were positioned in two ways: on opposite sides, with the bone between them, for the transverse measurement; and parallel to each other, on the same side of the bone plates, for the axial measurements. Results: In the axial transmission mode, the ultrasound velocity speed increased with cortical bone thickness, regardless of the distance between the transducers, up to a thickness of 5 mm, then remained constant thereafter. There were no changes in velocity when the transverse measures were made. Conclusion: Ultrasound velocity increased with cortical bone thickness in the axial transmission mode, until the thickness surpasses the wavelength, after which point it remained constant. Level of Evidence: Experimental Study.
Resumo:
The Hubble constant, H-0, sets the scale of the size and age of the Universe and its determination from independent methods is still worthwhile to be investigated. In this article, by using the Sunyaev-Zeldovich effect and X-ray surface brightness data from 38 galaxy clusters observed by Bonamente et al. (Astrophys J 647:25, 2006), we obtain a new estimate of H-0 in the context of a flat Lambda CDM model. There is a degeneracy on the mass density parameter (Omega(m)) which is broken by applying a joint analysis involving the baryon acoustic oscillations (BAO) as given by Sloan Digital Sky Survey. This happens because the BAO signature does not depend on H-0. Our basic finding is that a joint analysis involving these tests yield H-0 = 76.5(-3.33)(+3.35) km/s/mpc and Omega(m) = 0.27(-0.02)(+0.03). Since the hypothesis of spherical geometry assumed by Bonamente et al. is questionable, we have also compared the above results to a recent work where a sample of galaxy clusters described by an elliptical profile was used in analysis.
Resumo:
Invasive species are known to affect native species in a variety of ways, but the effect of acoustic invaders has not been examined previously. We simulated an invasion of the acoustic niche by exposing calling native male white-banded tree frogs (Hypsiboas albomarginatus) to recorded invasive American bullfrog (Lithobates catesbeianus) calls. In response, tree frogs immediately shifted calls to significantly higher frequencies. In the post-stimulus period, they continued to use higher frequencies while also decreasing signal duration. Acoustic signals are the primary basis of mate selection in many anurans, suggesting that such changes could negatively affect the reproductive success of native species. The effects of bullfrog vocalizations on acoustic communities are expected to be especially severe due to their broad frequency band, which masks the calls of multiple species simultaneously.
Resumo:
The present study sought to assess nasal respiratory function in adult patients with maxillary constriction who underwent surgically assisted rapid maxillary expansion (SARME) and to determine correlations between orthodontic measurements and changes in nasal area, volume, resistance, and airflow. Twenty-seven patients were assessed by acoustic rhinometry, rhinomanometry, orthodontic measurements, and use of a visual analogue scale at three time points: before surgery; after activation of a preoperatively applied palatal expander; and 4 months post-SARME. Results showed a statistically significant increase (p < 0.001) in all orthodontic measurements. The overall area of the nasal cavity increased after surgery (p < 0.036). The mean volume increased between assessments, but not significantly. Expiratory and inspiratory flow increased over time (p < 0.001). Airway resistance decreased between assessments (p < 0.004). Subjective analysis of the feeling of breathing exclusively through the nose increased significantly from one point in time to the next (p < 0.05). There was a statistical correlation between increased arch perimeter and decreased airway resistance. Respiratory flow was the only variable to behave differently between sides. The authors conclude that the SARME procedure produces major changes in the oral and nasal cavity; when combined, these changes improve patients' quality of breathing.
Resumo:
OBJECTIVES: The purpose of the study was to acoustically compare the performance of children who do and do not stutter on diadochokinesis tasks in terms of syllable duration, syllable periods, and peak intensity. METHODS: In this case-control study, acoustical analyses were performed on 26 children who stutter and 20 aged-matched normally fluent children (both groups stratified into preschoolers and school-aged children) during a diadochokinesis task: the repetition of articulatory segments through a task testing the ability to alternate movements. Speech fluency was assessed using the Fluency Profile and the Stuttering Severity Instrument. RESULTS: The children who stutter and those who do not did not significantly differ in terms of the acoustic patterns they produced in the diadochokinesis tasks. Significant differences were demonstrated between age groups independent of speech fluency. Overall, the preschoolers performed poorer. These results indicate that the observed differences are related to speech-motor age development and not to stuttering itself. CONCLUSIONS: Acoustic studies demonstrate that speech segment durations are most variable, both within and between subjects, during childhood and then gradually decrease to adult levels by the age of eleven to thirteen years. One possible explanation for the results of the present study is that children who stutter presented higher coefficients of variation to exploit the motor equivalence to achieve accurate sound production (i.e., the absence of speech disruptions).
Resumo:
Background: The aim of this study was to investigate the effects of sub-clinical alterations on the amplitudes and slopes of the DPOAE input-output responses from subjects with previous history of middle ear dysfunction. Material/Methods: The study included 15 subjects with and 15 subjects without a history of otitis media in the last 10 years. All participants were assessed with acoustic immittance, pure-tone audiometry, and DPOAEs. For the later, I/O functions and I/O slopes were estimated at 1501, 2002, 3174, 4004 and 6384Hz. Results: No statistically significant differences were found between the 2 groups in terms of behavioral thresholds. The group with a previous history of middle ear dysfunction presented significantly lower mean DPOAE amplitudes at 2002, 3174 and 4004 Hz. In terms of DPOAE slopes, no statistically significant differences were observed at the tested frequencies, except at 3174 Hz. Conclusions: Middle ear pathologies can produce subclinical alterations that are undetectable with traditional pure-tone audiometry. The data from the present study show that reduced amplitude DPOAEs are associated with a previous history of middle ear complications. The corresponding DPOAE slopes were affected at only 1 tested frequency, suggesting that the cochlear non-linearity is preserved. Considering these results, it remains to be elucidated to what degree the DPOAE amplitude attenuation interferes with higher-order auditory tasks.
Resumo:
A polarimetric X-band radar has been deployed during one month (April 2011) for a field campaign in Fortaleza, Brazil, together with three additional laser disdrometers. The disdrometers are capable of measuring the raindrop size distributions (DSDs), hence making it possible to forward-model theoretical polarimetric X-band radar observables at the point where the instruments are located. This setup allows to thoroughly test the accuracy of the X-band radar measurements as well as the algorithms that are used to correct the radar data for radome and rain attenuation. For the campaign in Fortaleza it was found that radome attenuation dominantly affects the measurements. With an algorithm that is based on the self-consistency of the polarimetric observables, the radome induced reflectivity offset was estimated. Offset corrected measurements were then further corrected for rain attenuation with two different schemes. The performance of the post-processing steps was analyzed by comparing the data with disdrometer-inferred polarimetric variables that were measured at a distance of 20 km from the radar. Radome attenuation reached values up to 14 dB which was found to be consistent with an empirical radome attenuation vs. rain intensity relation that was previously developed for the same radar type. In contrast to previous work, our results suggest that radome attenuation should be estimated individually for every view direction of the radar in order to obtain homogenous reflectivity fields.
Resumo:
Objective: Parameters to distinguish normal from deviant voices in early childhood have not been established. The current study sought to auditorily and acoustically characterize voices of children, and to study the relationship between vocal behavior reported by teachers and the presence of vocal aberrations. Methods: One hundred children between four and 6 years and 11 months, who attended early childhood educational institutions, were included. The sample comprised 50 children with normal voices (NVG) and 50 with deviant voices (DVG) matched by gender and age. All participants were submitted to auditory and acoustic analysis of vocal quality and had their vocal behaviors assessed by teachers through a specific protocol. Results: DVG had a higher incidence of breathiness (p < 0.001) and roughness (p < 0.001), but not vocal strain (p = 0.546), which was similar in both groups. The average F-0 was lower in the DVG and a higher noise component was observed in this group as well. Regarding the protocol used "Aspects Related to Phonotrauma - Children's Protocol", higher means were observed for children from DVG in all analyzed aspects and also on the overall means (DVG = 2.15; NVG = 1.12, p < 0.001). In NVG, a higher incidence of vocal behavior without alterations or with discrete alterations was observed, whereas a higher incidence of moderate, severe or extreme alterations of vocal behavior was observed in DVG. Conclusions: Perceptual assessment of voice, vocal acoustic parameters (F-0, noise and GNE), and aspects related to vocal trauma and vocal behavior differentiated the groups of children with normal voice and deviant voice. (C) 2012 Elsevier Ireland Ltd. All rights reserved.
Resumo:
The use of numerical simulation in the design and evaluation of products performance is ever increasing. To a greater extent, such estimates are needed in a early design stage, when physical prototypes are not available. When dealing with vibro-acoustic models, known to be computationally expensive, a question remains, which is related to the accuracy of such models in view of the well-know variability inherent to the mass manufacturing production techniques. In addition, both academia and industry have recently realized the importance of actually listening to a products sound, either by measurements or by virtual sound synthesis, in order to assess its performance. In this work, the scatter of significant parameter variations on a simplified vehicle vibro-acoustic model is calculated on loudness metrics using Monte Carlo analysis. The mapping from the system parameters to sound quality metric is performed by a fully-coupled vibro-acoustic finite element model. Different loudness metrics are used, including overall sound pressure level expressed in dB and Specific Loudness in Sones. Sound quality equivalent sources are used to excite this model and the sound pressure level at the driver's head position is acquired to be evaluated according to sound quality metrics. No significant variation has been perceived when evaluating the system using regular sound pressure level expressed in in dB and dB(A). This happens because of the third-octave filters that averages the results under some frequency bands. On the other hand, Zwicker Loudness presents important variations, arguably, due to the masking effects.
Resumo:
OBJECTIVE: To assess the effects of rapid maxillary expansion on facial morphology and on nasal cavity dimensions of mouth breathing children by acoustic rhinometry and computed rhinomanometry. METHODS: Cohort; 29 mouth breathing children with posterior crossbite were evaluated. Orthodontic and otorhinolaryngologic documentation were performed at three different times, i.e., before expansion, immediately after and 90 days following expansion. RESULTS: The expansion was accompanied by an increase of the maxillary and nasal bone transversal width. However, there were no significant differences in relation to mucosal area of the nose. Acoustic rhinometry showed no difference in the minimal cross-sectional area at the level of the valve and inferior turbinate between the periods analyzed, although rhinomanometry showed a statistically significant reduction in nasal resistance right after expansion, but were similar to pre-treatment values 90 days after expansion. CONCLUSION: The maxillary expansion increased the maxilla and nasal bony area, but was inefficient to increase the nasal mucosal area, and may lessen the nasal resistance, although there was no difference in nasal geometry. Significance: Nasal bony expansion is followed by a mucosal compensation.
Resumo:
The Pierre Auger Observatory in Malargüe, Argentina, is designed to study the properties of ultra-high energy cosmic rays with energies above 1018 eV. It is a hybrid facility that employs a Fluorescence Detector to perform nearly calorimetric measurements of Extensive Air Shower energies. To obtain reliable calorimetric information from the FD, the atmospheric conditions at the observatory need to be continuously monitored during data acquisition. In particular, light attenuation due to aerosols is an important atmospheric correction. The aerosol concentration is highly variable, so that the aerosol attenuation needs to be evaluated hourly. We use light from the Central Laser Facility, located near the center of the observatory site, having an optical signature comparable to that of the highest energy showers detected by the FD. This paper presents two procedures developed to retrieve the aerosol attenuation of fluorescence light from CLF laser shots. Cross checks between the two methods demonstrate that results from both analyses are compatible, and that the uncertainties are well understood. The measurements of the aerosol attenuation provided by the two procedures are currently used at the Pierre Auger Observatory to reconstruct air shower data.