6 resultados para Absorbance of control
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
BACKGROUND: Genetically modified MON 87701 X MON 89788 soybean (Glycine max), which expresses the Cry1Ac and EPSP-synthase proteins, has been registered for commercial use in Brazil. To develop an Insect Resistance Management (IRM) program for this event, laboratory and field studies were conducted to assess the high-dose concept and level of control it provides against Anticarsia gemmatalis and Pseudoplusia includens. RESULTS: The purified Cry1Ac protein was more active against A. gemmatalis [LC50 (FL 95%) = 0.23 (0.150.34) mu g Cry1Ac mL-1 diet] than P. includens [LC50 (FL 95%) = 3.72 (2.654.86) mu g Cry1Ac mL-1 diet]. In bioassays with freeze-dried MON 87701X MON 89788 soybean tissue diluted 25 times in an artificial diet, there was 100% mortality of A. gemmatalis and up to 95.79% mortality for P. includens. In leaf-disc bioassays and under conditions of high artificial infestation in the greenhouse and natural infestation in the field, MON 87701X MON 89788 soybean showed a high level of efficacy against both target pests. CONCLUSIONS: The MON 87701X MON 89788 soybean provides a high level of control against A. gemmatalis and P. includes, but a high-dose event only to A. gemmatalis. Copyright (c) 2012 Society of Chemical Industry
Resumo:
Different representations for a control surface freeplay nonlinearity in a three degree of freedom aeroelastic system are assessed. These are the discontinuous, polynomial and hyperbolic tangent representations. The Duhamel formulation is used to model the aerodynamic loads. Assessment of the validity of these representations is performed through comparison with previous experimental observations. The results show that the instability and nonlinear response characteristics are accurately predicted when using the discontinuous and hyperbolic tangent representations. On the other hand, the polynomial representation fails to predict chaotic motions observed in the experiments. (c) 2012 Elsevier Ltd. All rights reserved.
Resumo:
Computational fluid dynamics, CFD, is becoming an essential tool in the prediction of the hydrodynamic efforts and flow characteristics of underwater vehicles for manoeuvring studies. However, when applied to the manoeuvrability of autonomous underwater vehicles, AUVs, most studies have focused on the de- termination of static coefficients without considering the effects of the vehicle control surface deflection. This paper analyses the hydrodynamic efforts generated on an AUV considering the combined effects of the control surface deflection and the angle of attack using CFD software based on the Reynolds-averaged Navier–Stokes formulations. The CFD simulations are also independently conducted for the AUV bare hull and control surface to better identify their individual and interference efforts and to validate the simulations by comparing the experimental results obtained in a towing tank. Several simulations of the bare hull case were conducted to select the k –ω SST turbulent model with the viscosity approach that best predicts its hydrodynamic efforts. Mesh sensitivity analyses were conducted for all simulations. For the flow around the control surfaces, the CFD results were analysed according to two different methodologies, standard and nonlinear. The nonlinear regression methodology provides better results than the standard methodology does for predicting the stall at the control surface. The flow simulations have shown that the occurrence of the control surface stall depends on a linear relationship between the angle of attack and the control surface deflection. This type of information can be used in designing the vehicle’s autopilot system.
Resumo:
Building facilities have become important infrastructures for modern productive plants dedicated to services. In this context, the control systems of intelligent buildings have evolved while their reliability has evidently improved. However, the occurrence of faults is inevitable in systems conceived, constructed and operated by humans. Thus, a practical alternative approach is found to be very useful to reduce the consequences of faults. Yet, only few publications address intelligent building modeling processes that take into consideration the occurrence of faults and how to manage their consequences. In the light of the foregoing, a procedure is proposed for the modeling of intelligent building control systems, considersing their functional specifications in normal operation and in the of the event of faults. The proposed procedure adopts the concepts of discrete event systems and holons, and explores Petri nets and their extensions so as to represent the structure and operation of control systems for intelligent buildings under normal and abnormal situations. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
Costa-Silva JH, Zoccal DB, Machado BH. Chronic intermittent hypoxia alters glutamatergic control of sympathetic and respiratory activities in the commissural NTS of rats. Am J Physiol Regul Integr Comp Physiol 302: R785-R793, 2012. First published December 28, 2011; doi:10.1152/ajpregu.00363.2011.-Sympathetic overactivity and altered respiratory control are commonly observed after chronic intermittent hypoxia (CIH) exposure. However, the central mechanisms underlying such neurovegetative dysfunctions remain unclear. Herein, we hypothesized that CIH (6% O-2 every 9 min, 8 h/day, 10 days) in juvenile rats alters glutamatergic transmission in the commissural nucleus tractus solitarius (cNTS), a pivotal site for integration of peripheral chemoreceptor inputs. Using an in situ working heart-brain stem preparation, we found that L-glutamate microinjections (1, 3, and 10 mM) into the cNTS of control rats (n = 8) evoked increases in thoracic sympathetic nerve (tSN) and central vagus nerve (cVN) activities combined with inhibition of phrenic nerve (PN) activity. Besides, the ionotropic glutamatergic receptor antagonism with kynurenic acid (KYN; 250 mM) in the cNTS of control group (n = 7) increased PN burst duration and frequency. In the CIH group (n = 10), the magnitude of L-glutamate-induced cVN excitation was smaller, and the PN inhibitory response was blunted (P < 0.05). In addition, KYN microinjections into the cNTS of CIH rats (n = 9) did not alter PN burst duration and produced smaller increases in its frequency compared with controls. Moreover, KYN microinjections into the cNTS attenuated the sympathoexcitatory response to peripheral chemoreflex activation in control but not in CIH rats (P < 0.05). These functional CIH-induced alterations were accompanied by a significant 10% increase of N-methyl-D-aspartate receptor 1 (NMDAR1) and glutamate receptor 2/3 (GluR2/3) receptor subunit density in the cNTS (n = 3-8, P < 0.05), evaluated by Western blot analysis. These data indicate that glutamatergic transmission is altered in the cNTS of CIH rats and may contribute to the sympathetic and respiratory changes observed in this experimental model.
Resumo:
mitochondrial genomes are generally thought to be under selection for compactness, due to their small size, consistent gene content, and a lack of introns or intergenic spacers. As more animal mitochondrial genomes are fully sequenced, rearrangements and partial duplications are being identified with increasing frequency, particularly in birds (Class Ayes). In this study, we investigate the evolutionary history of mitochondrial control region states within the avian order Psittaciformes (parrots and cockatoos). To this aim, we reconstructed a comprehensive multi-locus phylogeny of parrots, used PCR of three diagnostic fragments to classify the mitochondrial control region state as single or duplicated, and mapped these states onto the phylogeny. We further sequenced 44 selected species to validate these inferences of control region state. Ancestral state reconstruction using a range of weighting schemes identified six independent origins of mitochondrial control region duplications within Psittaciformes. Analysis of sequence data showed that varying levels of mitochondrial gene and tRNA homology and degradation were present within a given clade exhibiting duplications. Levels of divergence between control regions within an individual varied from 0-10.9% with the differences occurring mainly between 51 and 225 nucleotides 3' of the goose hairpin in domain I. Further investigations into the fates of duplicated mitochondrial genes, the potential costs and benefits of having a second control region, and the complex relationship between evolutionary rates, selection, and time since duplication are needed to fully explain these patterns in the mitochondrial genome. (C) 2012 Elsevier Inc. All rights reserved.