11 resultados para Abi

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Cardiovascular disease is an important cause of death in patients on dialysis. Peripheral arterial disease (PAD) is a prognostic factor for cardiovascular disease. The ankle brachial index (ABI) is a noninvasive method used for the diagnosis of PAD. The difference between ABI pre- and post-dialysis had not yet been formally tested, and it was the main objective of this study. Methods:The ABI was assessed using an automated oscillometric device in incident patients on hemodialysis. All blood pressure readings were taken in triplicate pre- and post-dialysis in three consecutive dialysis sessions (times 1, 2, and 3). Results: One hundred and twenty-three patients (85 men) aged 53 +/- 19 years were enrolled. We found no difference in ABI pre- and post-dialysis on the right or left side, and there was no difference in times 1, 2, and 3. In patients with a history of PAD, the ABI pre- versus post-dialysis were of borderline significance on the right side (p = 0.088). Conclusion: ABI measured pre- and post-dialysis presented low variability. The ABI in patients with a history of PAD should be evaluated with caution. The applicability of the current method in predicting mortality among patients on hemodialysis therefore needs further investigation. Copyright (C) 2012 S. Karger AG, Basel

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To assess the setting time (ST), flow (FL), radiopacity (RD), solubility (SB) and dimensional change following setting (DC) of different sealers (AH Plus (R), Polifil, Apexit Plus (R), Sealapex (R), Endomethasone (R) and Endofill (R)) according to American National Standards Institute/American Dental Association (ANSI/ADA) Specification 57. Material and methods: Five samples of each material were used for each test. For ST, cast rings were filled with sealers and tested with a Gillmore needle. For FL, the sealer was placed on a glass plate. After 180 s, another plate with 20 g and a load of 100 g were applied on the material, and the diameters of the discs formed were measured. In RD, circular molds were filled with the sealers, radiographed and analyzed using Digora software. For SB, circular molds were filled with the sealers, a nylon thread was placed inside the material and another glass plate was positioned on the set, pressed and stored at 37 degrees C. Samples were weighed, placed in water, dried and reweighed. The water used for SB was analyzed by atomic absorption spectrometry. For DC, circular molds were filled with the sealers, covered by glass plates and stored at 37 degrees C. Samples were measured and stored in water for 30 days. After this period, they were dryed and measured again. Results: Regarding ST, AH Plus (R), Apexit (R) and Endofil (R) sealers are in accordance with ANSI/ADA standards. Endomethasone's manufacturer did not mention the ST; Polifil is an experimental sealer and Sealapex (R) did not set. Considering RD, SB and DC, all sealers were in accordance with ANSI/ADA. The spectrometric analysis showed that a significant amount of K+ and Zn2(+) ions was released from Apexit Plus (R) and Endofill (R), respectively. Conclusion: Except for DC, all other physicochemical properties of the tested sealers conformed to ANSI/ADA requirements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Arterial hypertension is an important risk factor for Lower-Limb Occlusive Arterial Disease (LLOAD). However, the correlation between blood pressure and pulse pressure (PP) with LLOAD severity and functional impairment resulting from this disease is not well established in the Brazilian population. Objective: To verify whether there is a correlation between blood pressure, PP, LLOAD severity and functional capacity in patients with symptomatic LLOAD. Methods: A total of 65 patients (62.2 + 8.1 years, 56.9% males) were evaluated. They were divided into two groups: normal (A) and high (B) blood pressure. LLOAD severity was assessed using the ankle-brachial index (ABI) and functional capacity by the total and pain-free walking distance at the 6-minute walking test (6MWT). Results: Group A consisted of 17 (26.1%) patients. The systolic (SBP), diastolic blood pressure (DBP), and PP were, respectively, 125.4 +/- 11.7, 74.5 +/- 9.1 and 50.9 +/- 10.0 mmHg in group A and 160.7 +/- 19.6, 90.0 +/- 12.2 and 70.7 +/- 20.2 mmHg in group B. The ABI was significantly lower in group B (0.66 +/- 0.12 vs. 0.57 +/- 0.13, p < 0.05). SBP and PP correlated with LLOAD severity and the distances walked at the 6MWT. Patients with PP > 40 mmHg walked shorter distances. Conclusion: SBP and PP significantly correlated with the distances walked in the 6MWT, suggesting they are clinical markers of functional capacity impairment in patients with symptomatic LLOAD. (Arq Bras Cardiol 2012; 98(2): 161-166)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conclusion: The extended retrolabyrinthine approach (RLA) is a safe and reliable approach for auditory brainstem placement in children. The surgical landmarks to reach cochlear nucleus are adequately exposed by this approach. Objective: To describe a new approach option for auditory brainstem implants (ABIs) in children, highlighting the anatomical landmarks to appropriately expose the foramen of Luschka. Methods: Three prelingually deafened children consecutively operated for ABIs via the RLA. Results: ABI placement via the RLA was successfully performed in all children without any further complications except multidirectional nystagmus in one child. The RLA we employed differed from that used for vestibular schwannoma only in the removal of the posterior semicircular canal. The lateral and superior semicircular canals and the vestibule remained intact, and there was no need to expose the dura of the internal auditory meatus. The jugular bulb was completely exposed to allow adequate visualization of the ninth cranial nerve and cerebellar flocculus.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Ankle-brachial index (ABI) can access peripheral artery disease and predict mortality in prevalent patients on hemodialysis. However, ABI has not yet been tested in incident patients, who present significant mortality. Typically, ABI is measured by Doppler, which is not always available, limiting its use in most patients. We therefore hypothesized that ABI, evaluated by a simplified method, can predict mortality in an incident hemodialysis population. Methodology/Principal Findings: We studied 119 patients with ESRD who had started hemodialysis three times weekly. ABI was calculated by using two oscillometric blood pressure devices simultaneously. Patients were followed until death or the end of the study. ABI was categorized in two groups normal (0.9-1.3) or abnormal (<0.9 and >1.3). There were 33 deaths during a median follow-up of 12 months (from 3 to 24 months). Age (1 year) (hazard of ratio, 1.026; p = 0.014) and ABI abnormal (hazard ratio, 3.664; p = 0.001) were independently related to mortality in a multiple regression analysis. Conclusions: An easy and inexpensive technique to measure ABI was tested and showed to be significant in predicting mortality. Both low and high ABI were associated to mortality in incident patients on hemodialysis. This technique allows nephrologists to identify high-risk patients and gives the opportunity of early intervention that could alter the natural progression of this population.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Statement of problem. Matrices of unsplinted attachment systems are generally reported to be the weak component of implant overdentures, often requiring frequent maintenance. Clinical wear results in reduced retention of the prosthesis, requiring activation or renewal of the matrix to restore the initial level of retention. Purpose. The purpose of this retrospective study was to measure the wear of the matrix of a ball attachment after various periods of clinical wear. Material and methods. Seventy specimens of 3 groups of matrices of ball attachments that had been in use for mean periods of 12.3 months (1Y group, n=26), 39.0 months (3Y group, n=28) and 95.6 months (8Y group, n=16) were retrieved from 35 patients (2 specimens per patient) and measured on a coordinate measuring machine equipped with a touch trigger probe. Ten unused matrices were used as controls (CTRL group). The external and internal matrix diameters and deviations from circularity were measured. For the various time periods, the decreases in matrix thickness were calculated and compared with controls. Kruskal-Wallis 1-way ANOVA by ranks, followed by the Mann-Whitney post hoc tests, were conducted to test for differences in median values among groups (alpha=.05). Results. For the internal upper diameter of the matrices tested, the Kruskal-Wallis and Mann-Whitney tests revealed significant differences for the 3 groups compared to the controls. For group 1Y, a significant difference (P<.001) of the internal upper diameter was found compared to the CTRL group. Compared to the controls, the nonparametric analyses for groups 3Y and 8Y showed significant differences for the internal upper diameter (P<.001) and deviations from circularity (P<.001). For groups 1Y, 3Y and 8Y, matrix thickness losses were 07, 47 and 70 pm, respectively. Conclusions. Within the limitations of this study, it was observed that one year of clinical wear had limited effect on the ball attachment matrices. Three to 8 years of clinical use resulted in a significant decrease of matrix thickness, especially at the tip of the retentive lamellae. (J Prosthet Dent 2012;107:191-198)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: This study assessed the relationship between lower limb hemodynamics and metabolic parameters with walking tolerance in patients with intermittent claudication (IC). Patients and methods: Resting ankle-brachial index (ABI), baseline blood flow (BF), BF response to reactive hyperemia (BFRH), oxygen uptake (VO2), initial claudication distance (ICD) and total walking distance (TWD) were measured in 28 IC patients. Pearson and Spearman correlations were calculated. Results: ABI, baseline BF and BF response to RH did not correlate with ICD or TWD. VO2 at first ventilatory threshold and VO(2)peak were significantly and positively correlated with ICD (r = 0.41 and 0.54, respectively) and TWD (r = 0.65 and 0.71, respectively). Conclusions: VO(2)peak and VO2 at first ventilatory threshold, but not ABI, baseline BF and BFHR were associated with walking tolerance in IC patients. These results suggest that VO2 at first ventilatory threshold may be useful to evaluate walking tolerance and improvements in IC patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim To identify aspects of health in postmenopausal Brazilian women using a health-related educational program provided by a multidisciplinary team as part of the primary care approach for early and late postmenopausal symptoms. Design A prospective cohort was formed with 69 postmenopausal women; they were divided into groups corresponding to early (n = 32) and late postmenopause (n = 37) through gynecological and clinical evaluations. We administered the Kuppermann-Blatt Menopausal Index and the Women's Health Questionnaire before and after health education instructions. Results The average age for the onset of menopause was 47.9 years (n = 69). Fifty women (72.5%) in this study had completed their primary education, 78.3% (n = 54) performed manual labor, and 60.9% (n = 42) showed concomitant chronic illnesses. After attending a series of health-related presentations, the mean weight of the women was reduced by 3.54% in early postmenopausal women (p < 0.001) and by 2.06% in the late postmenopausal group (p < 0.001). The mean abdominal circumference was reduced by 1.75% (p < 0.001) in the early postmenopausal group. In addition, the total score in the Kuppermann-Blatt Menopausal Index decreased by 34.38% in the early and by 33.33% in the late postmenopausal groups. According to the Women's Health Questionnaire, there was a decrease in the domain Depressive mood by 0.839 to 0.700 (p < 0.001) in the early and by 0.814 to 0.648 (p < 0.001) in the late postmenopausal groups. Conclusion Regardless of improving menopausal symptoms and anthropometric parameters, the effects of the multidisciplinary team activities in early postmenopausal women may be similar to those in late postmenopausal women.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The auditory brainstem implant (ABI) was first developed to help neurofibromatosis type 2 patients. Recently, its use has been recently extended to adults with non-tumor etiologies and children with profound hearing loss who were not candidates for a cochlear implant (Cl). Although the results has been extensively reported, the stimulation parameters involved behind the outcomes have received less attention. Objective: The aim of this study is to describe the audiologic outcomes and the MAP parameters in ABI adults and children at our center. Methods: Retrospective chart review. Five adults and four children were implanted with the ABI24M from September 2005 to June 2009. In the adult patients, four had Neurofibromatosis type 2, and one had postmeningitic deafness with complete ossification of both cochleae. Three of the children had cochlear malformation or dysplasia, and one had complete ossified cochlea due to meningitis. Map parameters as well as the intraoperative electrical auditory brainstem responses were collected. Evaluation was performed with at least six months of device use and included free-field hearing thresholds, speech perception tests in the adult patients and for the children, the Infant-Toddler Meaningful Auditory Integration Scale (IT-MAIS) and (ESP) were used to evaluate the development of auditory skills, besides the MUSS to evaluate. Results: The number of active electrodes that did not cause any non-auditory sensation varied from three to nineteen. All of them were programmed with SPEAK strategy, and the pulse widths varied from 100 to 300 mu s. Free-field thresholds with warble tones varied from very soft auditory sensation of 70 dBHL at 250 Hz to a pure tone average of 45 dBHL. Speech perception varied from none to 60% open-set recognition of sentences in silence in the adult population and from no auditory sensation at all to a slight improvement in the IT-MAIS/MAIS scores. Conclusion: We observed that ABI may be a good option for offering some hearing attention to both adults and children. In children, the results might not be enough to ensure oral language development. Programming the speech processor in children demands higher care to the audiologist. (C) 2011 Elsevier Ireland Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abstract Background Hepatitis B virus (HBV) can be classified into nine genotypes (A-I) defined by sequence divergence of more than 8% based on the complete genome. This study aims to identify the genotypic distribution of HBV in 40 HBsAg-positive patients from Rondônia, Brazil. A fragment of 1306 bp partially comprising surface and polymerase overlapping genes was amplified by PCR. Amplified DNA was purified and sequenced. Amplified DNA was purified and sequenced on an ABI PRISM® 377 Automatic Sequencer (Applied Biosystems, Foster City, CA, USA). The obtained sequences were aligned with reference sequences obtained from the GenBank using Clustal X software and then edited with Se-Al software. Phylogenetic analyses were conducted by the Markov Chain Monte Carlo (MCMC) approach using BEAST v.1.5.3. Results The subgenotypes distribution was A1 (37.1%), D3 (22.8%), F2a (20.0%), D4 (17.1%) and D2 (2.8%). Conclusions These results for the first HBV genotypic characterization in Rondônia state are consistent with other studies in Brazil, showing the presence of several HBV genotypes that reflects the mixed origin of the population, involving descendants from Native Americans, Europeans, and Africans.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: Rapid maxillary expansion (RME) for the treatment of maxillary deficiency and posterior crossbite may induce changes in the vertical dimension. Expanders with occlusal splints have been developed to minimize unwanted vertical effects. OBJECTIVE: This preliminary study used cephalometri radiographs to evaluate the vertical effects of RME using a Hyrax appliance in children with maxillary deficiency. METHOD: Twenty-six patients (11 boys; mean age = 8 years and 5 months) with maxillary deficiency and posterior crossbite were treated using a Hyrax appliance with an acrylic occlusal splint. Radiographs and cephalometric studies were performed before the beginning of the treatment (T1) and after RME active time (T2), at a mean interval of 7 months. Results were compared with normative values. RESULTS AND CONCLUSIONS: At the end of treatment, there were no statistically significant changes, and measurements were similar to the normative values. Data showed that there were no significant effects on vertical growth, which suggests that appliances with occlusal splints may be used to correct transverse deficiencies regardless of the patient's growth pattern.