11 resultados para AUDIOMETRY
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
New technology in the Freedom (R) speech processor for cochlear implants was developed to improve how incoming acoustic sound is processed; this applies not only for new users, but also for previous generations of cochlear implants. Aim: To identify the contribution of this technology - the Nucleus 22 (R) - on speech perception tests in silence and in noise, and on audiometric thresholds. Methods: A cross-sectional cohort study was undertaken. Seventeen patients were selected. The last map based on the Spectra (R) was revised and optimized before starting the tests. Troubleshooting was used to identify malfunction. To identify the contribution of the Freedom (R) technology for the Nucleus22 (R), auditory thresholds and speech perception tests were performed in free field in soundproof booths. Recorded monosyllables and sentences in silence and in noise (SNR = 0dB) were presented at 60 dBSPL. The nonparametric Wilcoxon test for paired data was used to compare groups. Results: Freedom (R) applied for the Nucleus22 (R) showed a statistically significant difference in all speech perception tests and audiometric thresholds. Conclusion: The reedom (R) technology improved the performance of speech perception and audiometric thresholds of patients with Nucleus 22 (R).
Resumo:
Objective: To evaluate the hearing status of patients being treated for pulmonary tuberculosis at referral hospitals in Brazil. Methods: This was a descriptive study involving 97 male and female inpatients/outpatients between 18 and 60 years of age who were undergoing treatment for active pulmonary tuberculosis at one of two referral hospitals in the state of Rio de Janeiro. After being interviewed, all of the patients underwent pure tone audiometry. Results: OF the 97 patients studied, 65 (67%) were male, 52 (54%) were receiving first-line treatment, and 45 (46%) were receiving second-line treatment, which included aminoglycosides. Smoking, alcohol consumption, exposure to noise, and ototoxic medication use were identified in 65 (67%), 51 (53%), 53 (55%), and 45 (46.4%) of the patients, respectively. The most common auditory and vestibular complaints were dizziness, in 28 patients (28.8%); tinnitus, in 27 (27.8%); and hypoacusis, in 23 (23.7%). Conclusions: Due to the great number of patients with hearing loss in the present study, we recommend that all patients under tuberculosis treatment be submitted to auditory monitoring.
Resumo:
In the present study, we evaluated peripheral and central auditory pathways in professional musicians (with and without hearing loss) compared to non-musicians. The goal was to verify if music exposure could affect auditory pathways as a whole. This is a prospective study that compared the results obtained between three groups (musicians with and without hearing loss and non-musicians). Thirty-two male individuals participated and they were assessed by: Immittance measurements, pure-tone air conduction thresholds at all frequencies from 0.25 to 20 kHz, Transient Evoked Otoacoustic Emissions, Auditory Brainstem Response (ABR), and Cognitive Potential. The musicians showed worse hearing thresholds in both conventional and high frequency audiometry when compared to the non-musicians; the mean amplitude of Transient Evoked Otoacoustic Emissions was smaller in the musicians group, but the mean latencies of Auditory Brainstem Response and Cognitive Potential were diminished in the musicians when compared to the non-musicians. Our findings suggest that the population of musicians is at risk for developing music-induced hearing loss. However, the electrophysiological evaluation showed that latency waves of ABR and P300 were diminished in musicians, which may suggest that the auditory training to which these musicians are exposed acts as a facilitator of the acoustic signal transmission to the cortex.
Resumo:
Background: The aim of this study was to investigate the effects of sub-clinical alterations on the amplitudes and slopes of the DPOAE input-output responses from subjects with previous history of middle ear dysfunction. Material/Methods: The study included 15 subjects with and 15 subjects without a history of otitis media in the last 10 years. All participants were assessed with acoustic immittance, pure-tone audiometry, and DPOAEs. For the later, I/O functions and I/O slopes were estimated at 1501, 2002, 3174, 4004 and 6384Hz. Results: No statistically significant differences were found between the 2 groups in terms of behavioral thresholds. The group with a previous history of middle ear dysfunction presented significantly lower mean DPOAE amplitudes at 2002, 3174 and 4004 Hz. In terms of DPOAE slopes, no statistically significant differences were observed at the tested frequencies, except at 3174 Hz. Conclusions: Middle ear pathologies can produce subclinical alterations that are undetectable with traditional pure-tone audiometry. The data from the present study show that reduced amplitude DPOAEs are associated with a previous history of middle ear complications. The corresponding DPOAE slopes were affected at only 1 tested frequency, suggesting that the cochlear non-linearity is preserved. Considering these results, it remains to be elucidated to what degree the DPOAE amplitude attenuation interferes with higher-order auditory tasks.
Resumo:
Abstract Objective To evaluate the functionality of the auditory system in patients who underwent radiotherapy and chemotherapy treatment with cisplatin to treat head and neck tumors. Study Design Case series with planned data collection. Setting From May 2007 to May 2008 by the Department of Otorhinolaryngology and the Department of Oncology/Radiotherapy at Faculdade de Medicina de Marília. Subjects and Methods Audiological evaluation (Pure Tone Audiometry (air and bone conduction), Speech Audiometry, Tympanometry, Acoustic Reflex testing and Distortion Product Otoacoustic Emissions) was performed in 17 patients diagnosed with head and neck neoplasia and treated with chemotherapy, using cisplatin, and radiotherapy. Results 12 left ears (70.5%) and 11 right ears (64.7%) presented bilateral decreased hearing soon after the treatment for the frequency 1 kHz (mild auditory damage) and for the frequency 8 kHz (more significant auditory damage). Conclusion Patients with head and neck cancer submitted to the conventional radiotherapy treatment, combined with the chemotherapy with cisplatin, presented a high incidence of decreased hearing by the end of treatment. Strong evidence was observed linking auditory alteration to the amount of radiotherapy treatment.
Resumo:
Introduction: At the initial consultation, the speech-language pathologist and audiologist may consider possible diagnostic hypotheses based on the child's history and the parents' complaint. Aim: To investigate the association of hearing complaints with the findings obtained in the conventional audiologic assessment in children with cleft lip and palate. Retrospective study. Methods: We analyzed medical charts of 1000 patients with cleft lip and palate who underwent surgical repair between 1988 and 1995 at a mean age of 6 years 8 months. We excluded charts with records of inconsistent audiological responses and charts with missing data for any of the audiologic evaluations considered. Thus, the sample consisted of 393 records. Results: Two hundred thirty-nine patients presented hearing loss in one or both ears, but only 3.8% reported hearing complaints. The most frequent were otorrhea followed by otalgia. There was no statistical significance between the complaint and gender (p = 0.26) nor between the complaint and hearing loss (p = 0.83). Conclusion: This study showed no association between the hearing complaint and the conventional audiologic assessment
Resumo:
Introduction: The implementation of hearing screening programs can be facilitated by reducing operating costs, including the cost of equipment. The Telessaúde (TS) audiometer is a low-cost, software-based, and easy-to-use piece of equipment for conducting audiometric screening. Aim: To evaluate the TS audiometer for conducting audiometric screening. Methods: A prospective randomized study was performed. Sixty subjects, divided into those who did not have (group A, n = 30) and those who had otologic complaints (group B, n = 30), underwent audiometric screening with conventional and TS audiometers in a randomized order. Pure tones at 25 dB HL were presented at frequencies of 500, 1000, 2000, and 4000 Hz. A "fail" result was considered when the individual failed to respond to at least one of the stimuli. Pure-tone audiometry was also performed on all participants. The concordance of the results of screening with both audiometers was evaluated. The sensitivity, specificity, and positive and negative predictive values of screening with the TS audiometer were calculated. Results: For group A, 100% of the ears tested passed the screening. For group B, "pass" results were obtained in 34.2% (TS) and 38.3% (conventional) of the ears tested. The agreement between procedures (TS vs. conventional) ranged from 93% to 98%. For group B, screening with the TS audiometer showed 95.5% sensitivity, 90.4% sensitivity, and positive and negative predictive values equal to 94.9% and 91.5%, respectively. Conclusions: The results of the TS audiometer were similar to those obtained with the conventional audiometer, indicating that the TS audiometer can be used for audiometric screening.
Resumo:
As novas tecnologias do processador Freedom® foram criadas para proporcionar melhorias no processamento do som acústico de entrada, não apenas para novos usuários, como para gerações anteriores de implante coclear. OBJETIVO: Identificar a contribuição da tecnologia do processador de fala Freedom® para implante coclear multicanal, Nucleus22®, no desempenho de percepção de fala no silêncio e no ruído, e nos limiares audiométricos. MATERIAL E MÉTODO: A forma de estudo foi de coorte histórico com corte transversal. Dezessete pacientes preencheram os critérios de inclusão. Antes de iniciar os testes, o último mapa em uso com o Spectra® foi revisto e otimizado e o funcionamento do processador foi verificado. Os testes de fala foram apresentados a 60dBNPS em material gravado: monossílabos; frases em apresentação aberta no silêncio; e no ruído (SNR = 0dB). Foram realizadas audiometrias em campo livre com ambos os processadores de fala. A análise estatística utilizou testes não-paramétricos. RESULTADOS: Quando analisada a contribuição do Freedom® para pacientes com Nucleus22®, observa-se diferença estatisticamente significativa em todos os testes de percepção de fala e em todos os limiares audiométricos. CONCLUSÃO: A tecnologia contribuiu no desempenho de percepção de fala e nos limiares audiométricos dos pacientes usuários de Nucleus22®.
Resumo:
INTRODUÇÃO: Na prática odontológica, o Cirurgião-Dentista está sujeito aos efeitos nocivos provocados por diversos agentes, como pelo ruído emitido por seus instrumentos de trabalho. Em 1959, a American Dental Association recomendava avaliações audiométricas periódicas e uso de proteção auditiva. São necessárias maiores informações sobre o comportamento auditivo dessa população: Cirurgiões-Dentistas, Auxiliares e Protéticos para se propor medidas de prevenção e tratamento precoce. OBJETIVO: Investigar os limiares de audibilidade em Cirurgiões-Dentistas, Auxiliares e Protéticos. MÉTODO: Forma de estudo: Estudo Clínico.Participaram 108 profissionais, sendo 44 Cirurgiões-Dentistas (GI), 36 Auxiliares (G II) e 28 Protéticos (GIII). Foram realizadas: entrevista específica, meatoscopia, audiometria tonal convencional e de altas frequências, logoaudiometria, imitanciometria. RESULTADOS: A comparação entre as médias dos limiares evidenciaram piora com o aumento da frequência para os 3 grupos testados; para a média tritonal de 500 a 2000Hz, e 3000 a 6000 Hz, o GIII apresentou os piores limiares, já para a média das altas frequências (9000 a 16.000Hz) o GII apresentou os piores limiares. CONCLUSÃO: A avaliação audiológica convencional não identificou exames alterados para os três grupos testados, no entanto, o exame da avaliação audiológica complementar como a audiometria de altas frequências indicou maior sensibilidade na detecção precoce de alterações auditivas uma vez que a perda auditiva dessa população acomete as frequências que não são testadas nos exames convencionais. Dessa maneira enfatizamos nesse trabalho a necessidade de inserir na rotina de exames a audiometria de altas frequências juntamente com os outros exames audiológicos.
Resumo:
INTRODUÇÃO: A perda auditiva relacionada ao trabalho é uma das doenças ocupacionais mais frequentes, progride ao longo dos anos de exposição ao ruído associado ao ambiente de trabalho, podendo causar prejuízos que comprometem as atividades físicas, fisiológicas e mentais do indivíduo além de causar lesão auditiva irreversível interferindo na comunicação e na qualidade de vida. Com alto índice de prevalência masculina, avalia-se que seja a segunda maior causa de perda de audição. Uma vez que não existe tratamento clínico para esse tipo de perda auditiva, fica evidente a importância de ações preventivas e coletivas que visem à conservação da audição e da saúde como um todo. OBJETIVO: Avaliar a prevalência de perdas auditivas nas audiometrias admissionais de motoristas. MÉTODO: Estudo retrospectivo. Participaram 76 prontuários de motoristas profissionais locados em empresas de transporte. Foram analisados os dados de entrevista específica e Audiometria Tonal Liminar. RESULTADOS: A prevalência de exames alterados foi de 22,36% com piores limiares para a média tritonal de 3.000, 4000 e 6.000Hz. Quanto maior a idade, maior os limiares auditivos. CONCLUSÃO: Este estudo permitiu evidenciar a ocorrência de alterações auditivas na ausência de queixas. Considerando que a PAIR é passível de prevenção, justifica-se a importância de ações coordenadas e multidisciplinares envolvendo, não só as equipes de saúde e segurança do trabalho, mas também as instituições envolvidas em preservar a saúde dos trabalhadores, como a equipe do SESMET, sindicatos ou Ministério Público.
Resumo:
OBJECTIVE: To identify the prevalence of hearing loss for the population in the urban area. METHODS: A cross-sectional household survey based on the World Health Organization Ear and Hearing Disorders Survey Protocol was conducted in 298 households in the urban area of Monte Negro, Rondonia, Northern Brazil, from 2005 to 2007. Ear examinations, behavioral audiometry and pure tone audiometry were conducted on 577 individuals. RESULTS: The results showed that 3.8% (95%CI 2.17;5.45) of population were classifi ed in the disabling hearing impairment category. The prevalence of moderate hearing impairment was 3.4%; severe impairment was 0.4%; and profound hearing impairment was not found. CONCLUSIONS: The impairing hearing loss prevalence found in this study is within of the international prevalence for this level of hearing loss and smaller than observed in a previous study in the South region of Brazil.