3 resultados para 79-4

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose. The primary objective of this study was to investigate the prevalence of clinically important potential drug-drug interactions (DDIs) in elderly patients attending the public primary health care system in Brazil. The secondary objective was to investigate possible predictors of potential DDIs. Methods. A cross-sectional study was carried out in 5 Brazilian cities located in the Ourinhos Micro-region, Sao Paulo State, between November 2010 and April 2011. The selected sample was divided according to the presence (exposed) or absence (unexposed) of one or more potential DDIs (defined as the presence of a minimum 5-day overlap in supply of an interacting drug pair). Data were collected from medical prescriptions and patients' medical records. Potential DDIs (rated major or moderate) were identified using 4 DDI-checker programs. Logistic regression analysis was used to study potential DDI predictors. Results. The prevalence of clinically important potential DDIs found during the study period was 47.4%. Female sex (OR = 2.49 [95% CI 2.29-2.75]), diagnosis of = 3 diseases (OR = 6.43 [95% CI 3.25-12.44]), and diagnosis of hypertension (OR = 1.68 [95% CI 1.23-2.41]) were associated with potential DDIs. The adjusted OR increased from 0.90 [95% CI 0.82-1.03] in patients aged 60 - 64 years to 4.03 [95% CI 3.79 - 4.28] in those aged 75 years or older. Drug therapy regimens involving = 2 prescribers (OR = 1.39 [95% CI 1.17-1.67]), = 3 drugs (OR = 3.21 [95% CI 2.78-3.59]), = 2 ATC codes (OR = 1.19 [95% CI 1.12-1.29]), = 2 drugs acting on cytochrome P450 (OR = 2.24 [95% CI 2.07-2.46]), and ATC codes B (OR = 1.89 [95% CI 1.05-2.08]) and C (OR = 4.01 [95% CI 3.55-4.57]) were associated with potential DDIs. Conclusion. Special care should be taken with the prescription and therapeutic follow-up of patients who present characteristics identified as predictors. Knowledge of potential DDI predictors could aid in developing preventive practices and policies that allow public health services to better manage this situation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: The rapid shallow breathing index (RSBI) is the most widely used index within intensive care units as a predictor of the outcome of weaning, but differences in measurement techniques have generated doubts about its predictive value. Objective: To investigate the influence of low levels of pressure support (PS) on the RSBI value of ill patients. Method: Prospective study including 30 patients on mechanical ventilation (MV) for 72 hours or more, ready for extubation. Prior to extubation, the RSBI was measured with the patient connected to the ventilator (Drager (TM) Evita XL) and receiving pressure support ventilation (PSV) and 5 cmH(2)O of positive end expiratory pressure or PEEP (RSBI_MIN) and then disconnected from the VM and connected to a Wright spirometer in which respiratory rate and exhaled tidal volume were recorded for 1 min (RSBI_ESP). Patients were divided into groups according to the outcome: successful extubation group (SG) and failed extubation group (FG). Results: Of the 30 patients, 11 (37%) failed the extubation process. In the within-group comparison (RSBI_MIN versus RSBI_ESP), the values for RSBI_MIN were lower in both groups: SG (34.79 +/- 4.67 and 60.95 +/- 24.64) and FG (38.64 +/- 12.31 and 80.09 +/- 20.71; p<0.05). In the between-group comparison, there was no difference in RSBI_MIN (34.79 +/- 14.67 and 38.64 +/- 12.31), however RSBI_ESP was higher in patients with extubation failure: SG (60.95 +/- 24.64) and FG (80.09 +/- 20.71; p<0.05). Conclusion: In critically ill patients on MV for more than 72h, low levels of PS overestimate the RSBI, and the index needs to be measured with the patient breathing spontaneously without the aid of pressure support.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: The aim of this study was to evaluate, ex vivo, the precision of five electronic root canal length measurement devices (ERCLMDs) with different operating systems: the Root ZX, Mini Apex Locator, Propex II, iPex, and RomiApex A-15, and the possible influence of the positioning of the instrument tips short of the apical foramen. Material and Methods: Forty-two mandibular bicuspids had their real canal lengths (RL) previously determined. Electronic measurements were performed 1.0 mm short of the apical foramen (-1.0), followed by measurements at the apical foramen (0.0). The data resulting from the comparison of the ERCLMD measurements and the RL were evaluated by the Wilcoxon and Friedman tests at a significance level of 5%. Results: Considering the measurements performed at 0.0 and -1.0, the precision rates for the ERCLMDs were: 73.5% and 47.1% (Root ZX), 73.5% and 55.9% (Mini Apex Locator), 67.6% and 41.1% (Propex II), 61.7% and 44.1% (iPex), and 79.4% and 44.1% (RomiApex A-15), respectively, considering ±0.5 mm of tolerance. Regarding the mean discrepancies, no differences were observed at 0.0; however, in the measurements at -1.0, the iPex, a multi-frequency ERCLMD, had significantly more discrepant readings short of the apical foramen than the other devices, except for the Propex II, which had intermediate results. When the ERCLMDs measurements at -1.0 were compared with those at 0.0, the Propex II, iPex and RomiApex A-15 presented significantly higher discrepancies in their readings. Conclusions: Under the conditions of the present study, all the ERCLMDs provided acceptable measurements at the 0.0 position. However, at the -1.0 position, the ERCLMDs had a lower precision, with statistically significant differences for the Propex II, iPex, and RomiApex A-15.