11 resultados para 560
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
The development of new electroluminescence polymers for specific colour tuning in Polymer Light Emitting Devices (PLEDs) is currently one of the most important fields for organic electronics. This work reports a synthesis of a new electroluminescent polymer and the concomitant test as PLED emissive layer. The polymer, synthesised from fluorene, is poly(9,9`-n-dihexil-2,7-fluorenodiilvinylene-alt-2,5thiophene) or PFT The luminescence shows large bands with maxima around 480 nm in absorption and 560 nm in emission. The device was made in a three layer structure, with PEDOT:PSS as hole transport layer, PFT as emissive layer and butyl-PBD as electron transport layer. The electroluminescence spectrum shows a strong band peaked at 540 nm. For an applied voltage of 12 Volt, the brightness at normal angle of viewing is near 10 cd/m(2) and the luminous efficiency is of 0.01 lm/W. A discussion about carrier transport and the electroluminescence properties is made.
Resumo:
Purpose: Bacterial leakage along the implant-abutment interface, with consequent species harboring the inner parts of two-part dental implant systems, has been reported in the literature. The aim of this in vitro study was to evaluate bacterial leakage from human saliva to the internal part of the implants along the implant-abutment interface under loaded and unloaded conditions using DNA Checkerboard. Materials and Methods: Sixty denial implants-20 each of external-hexagon, internal-hexagon, and Morse cone-connection designs-and their conical abutments were used in this study. Each group was subdivided into two groups of 10 loaded and 10 unloaded implants. The assemblies were immersed in human saliva and either (1) loaded with 500,000 cycles at 120 N (experimental group) or (2) incubated in static conditions for 7 days at 35 degrees C (unloaded control group). Results: Microorganisms were found in the internal surfaces of all types of connections. The Morse cone connection presented the lowest count of microorganisms in both the unloaded and loaded groups. Loaded implants presented with higher counts of microorganisms than unloaded implants for external- and internal-hex connections. Conclusion: Bacterial species from human saliva may penetrate along the implant-abutment interface under both unloaded and loaded conditions for all connections evaluated. Morse cone-connection implants showed the lowest counts of microorganisms for both conditions. External- and internal-hex implants showed a higher incidence of bacteria and higher bacterial counts after simulated loading. INT J ORAL MAXILLOFAC IMPLANTS 2012;27:551-560.
Resumo:
Sugarcane bagasse cellulose was subjected to the extremely low acid (ELA) hydrolysis in 0.07% H2SO4 at 190, 210 and 225 degrees C for various times. The cellulose residues from this process were characterized by TGA, XRD, GPC, FIR and SEM. A kinetic study of thermal decomposition of the residues was also carried out, using the ASTM and Kissinger methods. The thermal studies revealed that residues of cellulose hydrolyzed at 190, 210 and 225 degrees C for 80,40 and 8 min have initial decomposition temperature and activation energy for the main decomposition step similar to those of Avicel PH-101. XRD studies confirmed this finding by showing that these cellulose residues are similar to Avicel in crystallinity index and crystallite size in relation to the 110 and 200 planes. FTIR spectra revealed no significant changes in the cellulose chemical structure and analysis of SEM micrographs demonstrated that the particle size of the cellulose residues hydrolyzed at 190 and 210 degrees C were similar to that of Avicel. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
In this study, a novel material for the electrochemical determination of bisphenol A using a nanocomposite based on multi-walled carbon nanotubes modified with antimony nanoparticles has been investigated. The morphology, structure, and electrochemical performance of the nanocomposite electrodes were characterised by field emission gun scanning electron microscopy, energy-dispersive X-ray spectroscopy, and cyclic voltammetry. A scan rate study and electrochemical impedance spectroscopy showed that the bisphenol A oxidation product is adsorbed on nanocomposite electrode surface. Differential pulse voltammetry in phosphate buffer solution at pH 6, allowed the development of a method to determine bisphenol A levels in the range of 0.5-5.0 mu mol L-1, with a detection limit of 5.24 nmol L-1 (1.19 mu g L-1). (C) 2012 Elsevier Ltd. All rights reserved.
Resumo:
The purpose of the present study was to determine ultrasound (US) arthrography diagnostic accuracy in patients with recurrent shoulder dislocation by comparing US arthrography and magnetic resonance arthrography (MRA) with intraoperative findings. Fifty-six consecutive patients with diagnosis of chronic anterior instability of the shoulder were evaluated for assessment of bone and soft tissue lesions by three radiologists. Twenty-five cases were confirmed by surgery. Sensitivity, specificity, inter-and intraobserver agreement were calculated. Ultrasound sensitivity ranged from 20% to 100% and specificity from 25% to 90%. MRA sensitivity ranged from 80% to 100% and specificity from 50% to 100%. Interobserver agreement was good for MRA (0.54-0.70) and fair for US arthrography (0.19-0.40). Despite a higher interobserver variability for US arthrography than for MRA, our results indicate that US is capable of demonstrating bone and soft tissue lesions related to chronic instability of the shoulder in the presence of intra-articular fluid. (E-mail: marcelo_simao@hotmail.com) (C) 2012 World Federation for Ultrasound in Medicine & Biology.
Resumo:
Solar infrared colors provide powerful constraints on the stellar effective temperature scale, but they must be measured with both accuracy and precision in order to do so. We fulfill this requirement by using line-depth ratios to derive in a model-independent way the infrared colors of the Sun, and we use the latter to test the zero point of the Casagrande et al. effective temperature scale, confirming its accuracy. Solar colors in the widely used Two Micron All Sky Survey (2MASS) JHK(s) and WISE W1-4 systems are provided: (V - J)(circle dot) = 1.198, (V - H)(circle dot) = 1.484, (V - K-s)(circle dot) = 1.560, (J - H)(circle dot) = 0.286, (J - K-s)(circle dot) = 0.362, (H - K-s)(circle dot) = 0.076, (V - W1)(circle dot) = 1.608, (V - W2)(circle dot) = 1.563, (V - W3)(circle dot) = 1.552, and (V - W4)(circle dot) = 1.604. A cross-check of the effective temperatures derived implementing 2MASS or WISE magnitudes in the infrared flux method confirms that the absolute calibration of the two systems agrees within the errors, possibly suggesting a 1% offset between the two, thus validating extant near-and mid-infrared absolute calibrations. While 2MASS magnitudes are usually well suited to derive T-eff, we find that a number of bright, solar-like stars exhibit anomalous WISE colors. In most cases, this effect is spurious and can be attributed to lower-quality measurements, although for a couple of objects (3%+/- 2% of the total sample) it might be real, and may hint at the presence of warm/hot debris disks.
Resumo:
The ornamental market is dynamic and demands constant novelties. The use of fruit crops as ornamental plants can be an interesting alternative with very differentiated and original products. The banana germplasm bank at Embrapa Cassava and Fruits has been primarily used in the breeding program for generating new cultivars as food. To diversify and expand the use of this collection, accessions with ornamental potential have been selected to obtain new hybrids. This work was aimed at characterizing the progeny of ornamental Musa L. spp. by grouping the hybrids according to the following uses: landscape plants, potted plants, cut flower, or minifruits. Forty-two hybrids were evaluated with 14 quantitative and 12 qualitative descriptors in three production cycles. In addition, assays for resistance to black and yellow Sigatoka and to Fusarium wilt were performed. Variability was observed for all the characteristics evaluated within progenies, especially with regard to leaf color, fruit, peduncle, rachis, and heart. All evaluated hybrids were resistant to yellow Sigatoka and to Fusarium wilt and were resistant or showed reduced symptoms of susceptibility to black Sigatoka. Most hybrids (82%) presented reduced plant height. After clustering by use category, the hybrids RM 09, RM 38, RM 37, and RM 33 were selected and recommended to be used as cut flowers, minifruits, or landscaping plants.
Resumo:
Seventy-seven males of Hypsiboas prasinus from 2 Atlantic forest fragments in the municipalities of Botucatu and Jundiai, sao Paulo State, Brazil, were examined for endoparasites. The frogs were captured in summer (January until March) and winter (July/August) of 2008 and 2009. Thirty-three males (75%) from Botucatu were infected with Rhabdias cf. fuelleborni, cosmocerciid nematodes, and Cylindrotaenia americana. Twenty-five tree frogs (78.5%) from Jundiai were infected by Rhabdias cf. fuelleborni, Physaloptera sp., and cosmocerciid nematodes. Only cosmocerciid nematodes presented a statistically significance difference in prevalence (z = 4.345; P < 0.001) and mean abundance (t = 562.0; P < 0.001) between Botucatu and Jundiai during the winter. Also, the cosmocerciids exhibited higher mean abundance (t = 196.0; P = 0.034) in winter when compared with summer at the Jundiai site. Moreover, to our knowledge, this is the first report of C. americana in the Brazilian Hylidae. This study presents 4 new records of nematodes in H. prasinus.
Resumo:
The exploration of novel synthetic methodologies that control both size and shape of functional nanostructure opens new avenues for the functional application of nanomaterials. Here, we report a new and versatile approach to synthesize SnO2 nanocrystals (rutile-type structure) using microwave-assisted hydrothermal method. Broad peaks in the X-ray diffraction spectra indicate the nanosized nature of the samples which were indexed as a pure cassiterite tetragonal phase. Chemically and physically adsorbed water was estimated by TGA data and FT-Raman spectra to account for a new broad peak around 560 cm(-1) which is related to defective surface modes. In addition, the spherical-like morphology and low dispersed distribution size around 3-5 nm were investigated by HR-TEM and FE-SEM microscopies. Room temperature PL emission presents two broad bands at 438 and 764 nm, indicating the existence of different recombination centers. When the size of the nanospheres decreases, the relative intensity of 513 nm emission increases and the 393 nm one decreases. UV-Visible spectra show substantial changes in the optical absorbance of crystalline SnO2 nanoparticles while the existence of a small tail points out the presence of localized levels inside the forbidden band gap and supplies the necessary condition for the PL emission.
Resumo:
A utilização de técnicas ultrassonográficas na área de Medicina Veterinária está cada vez mais presente e a capacitação nesta área tornou-se indispensável para o clínico, auxiliando-o na obtenção de informações rápidas e valiosas das afecções patológicas que podem acometer os animais. O exame ultrassonográfico renal revelou-se de grande importância neste âmbito, com o objetivo de avaliar e mensurar os parâmetros morfométricos renais normais de fêmeas caprinas (Capra hircus). Por meio de técnicas ultrassonográficas procedeu-se o estudo de 30 fêmeas da raça Saanen, divididas em três grupos: fêmeas com idade inferior a 6 meses (3,0±1,0 meses), de 6-18 meses (9,0±4,3 meses) e com idade superior a 18 meses (46,3±17,4 meses). Realizaram-se imagens dos rins, em secções longitudinais, medidas de comprimento e largura e, em secções transversais, medidas de altura (ou espessura). Com estes valores calcularam-se volumes renais, corticais e medulares, além da relação cortico-medular. Com relação ao comprimento renal os grupos com idade inferior a 6 meses, de 6-18 meses e com idade superior a 18 meses obtiveram média e desvio padrão de 4,20±0,36cm, 5,56±0,40cm e 6,77±0,64cm, respectivamente. Tratando-se do volume renal, estes grupos apresentaram média e desvio padrão de 17,02±3,99cm³, 19,99±5,86cm³; e, 41,23±13,05cm³. Comparou-se a equivalência métrica das médias entre os dois rins de forma que os parâmetros volumétricos e lineares renais com diferença entre si são comprimento renal, volume renal e volume cortical para o grupo de fêmeas com idade de 6-18 meses, e comprimento renal e comprimento medular para o grupo com idade superior a 18 meses. Entre diferentes grupos observou-se que somente o comprimento medular esquerdo apresentou média equivalente em todos os grupos, ou seja, entre o grupo com idade inferior a 6 meses e o grupo com idade de 6-18 meses e, entre este último e o grupo com idade superior a 18 meses. Os resultados mostraram correlações diretas e positivas entre peso corporal e idade com os parâmetros lineares e volumétricos, a relação cortico-medular esquerda foi a única que apresentou correlação significativa com o peso (r= -0,365; P = 0,047). Para aqueles parâmetros que apresentaram correlação significativa foi realizada análise de regressão, obtendo-se a linha de melhor ajuste das variáveis.
Resumo:
The use of piezoelectric materials for the development of electromechanical devices for the harvesting or scavenging of ambient vibrations has been extensively studied over the last decade. The energy conversion from mechanical (vibratory) to electrical energy is provided by the electromechanical coupling between mechanical strains/stresses and electric charges/voltages in the piezoelectric material. The majority of the studies found in the open literature present a tip-mass cantilever piezoelectric device tuned on the operating frequency. Although recent results show that these devices can be quite effective for harvesting small amounts of electrical energy, little has been published on the robustness of these devices or on the effect of parametric uncertainties on the energy harvested. This work focuses on a cantilever plate with bonded piezoelectric patches and a tip-mass serving as an energy harvesting device. The rectifier and storage electric circuit was replaced by a resistive circuit (R). In addition, an alternative to improve the harvesting performance by adding an inductance in series to the harvesting circuit, thus leading to a resonant circuit (RL), is considered. A coupled finite element model leading to mechanical (displacements) and electrical (charges at electrodes) degrees of freedom is considered. An analysis of the effect of parametric uncertainties of the device on the electric output is performed. Piezoelectric and dielectric constants of the piezoelectric active layers and electric circuit equivalent inductance are considered as stochastic parameters. Mean and confidence intervals of the electric output are evaluated.