3 resultados para 230Th-normalised

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Proposed is a symbol-based decision-directed algorithm for blind equalisation of quadrature amplitude modulation (QAM) signals using a decision feedback scheme. Independently of QAM order, it presents: (i) an error equal to zero when the equaliser output coincides with the transmitted signal; (ii) simultaneous recovery of the modulus and phase of the signal; (iii) a misadjustment close to that of the normalised least-mean squares algorithm; (iv) fast convergence; and (v) the avoidance of degenerative solutions. Additionally, its stability is ensured when the step-size is properly chosen.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work evaluates the spatial distribution of normalised rates of droplet breakage and droplet coalescence in liquidliquid dispersions maintained in agitated tanks at operation conditions normally used to perform suspension polymerisation reactions. Particularly, simulations are performed with multiphase computational fluid dynamics (CFD) models to represent the flow field in liquidliquid styrene suspension polymerisation reactors for the first time. CFD tools are used first to compute the spatial distribution of the turbulent energy dissipation rates (e) inside the reaction vessel; afterwards, normalised rates of droplet breakage and particle coalescence are computed as functions of e. Surprisingly, multiphase simulations showed that the rates of energy dissipation can be very high near the free vortex surfaces, which has been completely neglected in previous works. The obtained results indicate the existence of extremely large energy dissipation gradients inside the vessel, so that particle breakage occurs primarily in very small regions that surround the impeller and the free vortex surface, while particle coalescence takes place in the liquid bulk. As a consequence, particle breakage should be regarded as an independent source term or a boundary phenomenon. Based on the obtained results, it can be very difficult to justify the use of isotropic assumptions to formulate particle population balances in similar systems, even when multiple compartment models are used to describe the fluid dynamic behaviour of the agitated vessel. (C) 2011 Canadian Society for Chemical Engineering

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background In ROCKET AF, rivaroxaban was non-inferior to adjusted-dose warfarin in preventing stroke or systemic embolism among patients with atrial fibrillation (AF). We aimed to investigate whether the efficacy and safety of rivaroxaban compared with warfarin is consistent among the subgroups of patients with and without previous stroke or transient ischaemic attack (TIA). Methods In ROCKET AF, patients with AF who were at increased risk of stroke were randomly assigned (1:1) in a double-blind manner to rivaroxaban 20 mg daily or adjusted dose warfarin (international normalised ratio 2-0-3.0). Patients and investigators were masked to treatment allocation. Between Dec 18,2006, and June 17,2009,14 264 patients from 1178 centres in 45 countries were randomly assigned. The primary endpoint was the composite of stroke or non-CNS systemic embolism. In this substudy we assessed the interaction of the treatment effects of rivaroxaban and warfarin among patients with and without previous stroke or TIA. Efficacy analyses were by intention to treat and safety analyses were done in the on-treatment population. ROCKET AF is registered with ClinicalTrials.gov, number NCT00403767. Findings 7468 (52%) patients had a previous stroke (n=4907) or TIA (n=2561) and 6796 (48%) had no previous stroke or TIA. The number of events per 100 person-years for the primary endpoint in patients treated with rivaroxaban compared with warfarin was consistent among patients with previous stroke or TIA (2.79% rivaroxaban vs 2.96% warfarin; hazard ratio [HR] 0-94,95% CI 0.77-1.16) and those without (1.44% vs 1.88%; 0.77, 0.58-1-01; interaction p=0.23). The number of major and non-major clinically relevant bleeding events per 100 person-years in patients treated with rivaroxaban compared with warfarin was consistent among patients with previous stroke or TIA (13.31% rivaroxaban vs 13.87% warfarin; HR 0.96,95% CI 0.87-1-07) and those without (16.69% vs 15.19%; 1.10, 0.99-1.21; interaction p=0.08). Interpretation There was no evidence that the relative efficacy and safety of rivaroxaban compared with warfarin was different between patients who had a previous stroke or TIA and those who had no previous stroke or TIA. These results support the use of rivaroxaban as an alternative to warfarin for prevention of recurrent as well as initial stroke in patients with AF.