6 resultados para 100602 Input Output and Data Devices

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The aim of this study was to investigate the effects of sub-clinical alterations on the amplitudes and slopes of the DPOAE input-output responses from subjects with previous history of middle ear dysfunction. Material/Methods: The study included 15 subjects with and 15 subjects without a history of otitis media in the last 10 years. All participants were assessed with acoustic immittance, pure-tone audiometry, and DPOAEs. For the later, I/O functions and I/O slopes were estimated at 1501, 2002, 3174, 4004 and 6384Hz. Results: No statistically significant differences were found between the 2 groups in terms of behavioral thresholds. The group with a previous history of middle ear dysfunction presented significantly lower mean DPOAE amplitudes at 2002, 3174 and 4004 Hz. In terms of DPOAE slopes, no statistically significant differences were observed at the tested frequencies, except at 3174 Hz. Conclusions: Middle ear pathologies can produce subclinical alterations that are undetectable with traditional pure-tone audiometry. The data from the present study show that reduced amplitude DPOAEs are associated with a previous history of middle ear complications. The corresponding DPOAE slopes were affected at only 1 tested frequency, suggesting that the cochlear non-linearity is preserved. Considering these results, it remains to be elucidated to what degree the DPOAE amplitude attenuation interferes with higher-order auditory tasks.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In contrast to the impressive advances in somatic research of erectile dysfunction (ED), scientific literature shows contradictory reports on the results of psychotherapy for the treatment of ED. Authors conducted a meta-analysis to evaluate the effectiveness of psychological interventions for the treatment of ED compared to oral drugs, local injection, vacuum devices, or other psychological intervention. Distinct sources of randomized controlled trials (RCTs) were searched: electronic databases (between 1966 and 2007), cross checking of references, and contact with scientific societies. For dichotomous outcomes the pooled relative risks were calculated and for continuous outcomes mean differences between interventions. Statistical heterogeneity was addressed. Eleven RCTs involving 398 men met the inclusion criteria. There is evidence that group therapy improves ED. Focused sex group therapy showed greater efficacy than control group. Men randomized to receive psychotherapy plus sildenafil showed significant improvement of ED and were less likely than those receiving only sildenafil to drop out. Regarding to the effectiveness of psychological interventions for the treatment of ED compared to local injection and vacuum devices no difference was found. Melnik T, Soares BGO, and Nasello AG. The effectiveness of psychological interventions for the treatment of erectile dysfunction: Systematic review and meta-analysis, including comparisons to sildenafil treatment, intracavernosal injection, and vacuum devices. J Sex Med 2008;5:2562-2574.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The reproductive performance of cattle may be influenced by several factors, but mineral imbalances are crucial in terms of direct effects on reproduction. Several studies have shown that elements such as calcium, copper, iron, magnesium, selenium, and zinc are essential for reproduction and can prevent oxidative stress. However, toxic elements such as lead, nickel, and arsenic can have adverse effects on reproduction. In this paper, we applied a simple and fast method of multi-element analysis to bovine semen samples from Zebu and European classes used in reproduction programs and artificial insemination. Samples were analyzed by inductively coupled plasma spectrometry (ICP-MS) using aqueous medium calibration and the samples were diluted in a proportion of 1:50 in a solution containing 0.01% (vol/vol) Triton X-100 and 0.5% (vol/vol) nitric acid. Rhodium, iridium, and yttrium were used as the internal standards for ICP-MS analysis. To develop a reliable method of tracing the class of bovine semen, we used data mining techniques that make it possible to classify unknown samples after checking the differentiation of known-class samples. Based on the determination of 15 elements in 41 samples of bovine semen, 3 machine-learning tools for classification were applied to determine cattle class. Our results demonstrate the potential of support vector machine (SVM), multilayer perceptron (MLP), and random forest (RF) chemometric tools to identify cattle class. Moreover, the selection tools made it possible to reduce the number of chemical elements needed from 15 to just 8.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The objective of this study was to improve the feasibility of applying topic 5-aminolevulinic acid (ALA) in photodiagnosis (PD) and treatment of condyloma caused by human papillomavirus (HPV) using two homemade handheld devices and to discuss the photodynamic therapy (PDT) as a suitable alternative for each of the cases studied. Both, protoporphyrin IX production and photodegradation were analyzed, and the pain experienced during the illumination was correlated with the light intensities. Methods: A total of 40 women with different grades of lesions caused by HPV were chosen from patients of the School of Medicine of Ribeirao Preto (University of Sao Paulo) and of the Unit of Public Health of Araraquara, Sao Paulo. Results: We did not encounter any unexpected difficulties using our devices during the treatment. The existence of an easily observable reddish fluorescence with large intensity concentrated on the Lesions is the clinical indication of the penetration and the selective concentration of protoporphyrin IX in the clinical and subclinical lesions rather than in the healthy tissue. The aesthetic results were much better than those obtained by conventional techniques as surgery or cryogenics, with no recurrence reported after two years of treatment. Conclusions: Our results are proof for the various advantages using ALA cream for the PD and PDT in many different cases of condyloma by HPV. This study will be continued to investigate the PpIX photobleaching and the irradiance and fluence rate to optimize conducting the clinical trials, to improve the devices and therefore increase the treatment response. (c) 2011 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract Background The study and analysis of gene expression measurements is the primary focus of functional genomics. Once expression data is available, biologists are faced with the task of extracting (new) knowledge associated to the underlying biological phenomenon. Most often, in order to perform this task, biologists execute a number of analysis activities on the available gene expression dataset rather than a single analysis activity. The integration of heteregeneous tools and data sources to create an integrated analysis environment represents a challenging and error-prone task. Semantic integration enables the assignment of unambiguous meanings to data shared among different applications in an integrated environment, allowing the exchange of data in a semantically consistent and meaningful way. This work aims at developing an ontology-based methodology for the semantic integration of gene expression analysis tools and data sources. The proposed methodology relies on software connectors to support not only the access to heterogeneous data sources but also the definition of transformation rules on exchanged data. Results We have studied the different challenges involved in the integration of computer systems and the role software connectors play in this task. We have also studied a number of gene expression technologies, analysis tools and related ontologies in order to devise basic integration scenarios and propose a reference ontology for the gene expression domain. Then, we have defined a number of activities and associated guidelines to prescribe how the development of connectors should be carried out. Finally, we have applied the proposed methodology in the construction of three different integration scenarios involving the use of different tools for the analysis of different types of gene expression data. Conclusions The proposed methodology facilitates the development of connectors capable of semantically integrating different gene expression analysis tools and data sources. The methodology can be used in the development of connectors supporting both simple and nontrivial processing requirements, thus assuring accurate data exchange and information interpretation from exchanged data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There are several electrophysiological systems available commercially. Usually, control groups are required to compare their results, due to the differences between display types. Our aim was to examine the differences between CRT and LCD/TFT stimulators used in pattern VEP responses performed according to the ISCEV standards. We also aimed to check different contrast values toward thresholds. In order to obtain more precise results, we intended to measure the intensity and temporal response characteristics of the monitors with photometric methods. To record VEP signals, a Roland RetiPort electrophysiological system was used. The pattern VEP tests were carried out according to ISCEV protocols on a CRT and a TFT monitor consecutively. Achromatic checkerboard pattern was used at three different contrast levels (maximal, 75, 25%) using 1A degrees and 15` check sizes. Both CRT and TFT displays were luminance and contrast matched, according to the gamma functions based on measurements at several DAC values. Monitor-specific luminance parameters were measured by means of spectroradiometric instruments. Temporal differences between the displays` electronic and radiometric signals were measured with a device specifically built for the purpose. We tested six healthy control subjects with visual acuity of at least 20/20. The tests were performed on each subject three times on different days. We found significant temporal differences between the CRT and the LCD monitors at all contrast levels and spatial frequencies. In average, the latency times were 9.0 ms (+/- 3.3 ms) longer with the TFT stimulator. This value is in accordance with the average of the measured TFT input-output temporal difference values (10.1 +/- A 2.2 ms). According to our findings, measuring the temporal parameters of the TFT monitor with an adequately calibrated measurement setup and correcting the VEP data with the resulting values, the VEP signals obtained with different display types can be transformed to be comparable.