80 resultados para Computed tomography


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Patients with hydrocephalus and risk factors for overdrainage may be submitted to ventricular shunt (VS) implant with antisiphon device. The objective of this study was to prospectively evaluate for two years the clinical and tomographic results of the implant of fixed-pressure valves with antisiphon device SPHERA (R) in 35 adult patients, with hydrocephalus and risk factors for overdrainage. Of these, 3 had congenital hydrocephalus in adult patients with very dilated ventricles (Evans index >50%), 3 had symptomatic overdrainage after previous VS implant (subdural hematoma, hygroma or slit ventricle syndrome), 1 had previous chronic subdural hematoma, 15 had normal pressure hydrocephalus with final lumbar pressure <5 cm H2O after tap test (40 mL), 6 had pseudotumor cerebri, and 7 had hydrocephalus due to other causes. Clinical improvement was observed and sustained in 94.3% of the patients during the two-year period with no computed tomography (CT) evidence of hypo or overdrainage, and no immediate early or late significant complications.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objectives: Previous evidence supports a direct relationship between the calcium burden (volume) on post-contrast CT with the percent internal carotid artery (ICA) stenosis at the carotid bifurcation. We sought to further investigate this relationship by comparing non-enhanced CT (NECT) and digital subtraction angiography (DSA). Methods: 50 patients (aged 41-82 years) were retrospectively identified who had undergone cervical NECT and DSA. A 64-multidetector array CT (MDCT) scanner was utilised and the images reviewed using preset window widths/levels (30/300) optimised to calcium, with the volumes measured via three-dimensional reconstructive software. Stenosis measurements were performed on DSA and luminal diameter stenoses >40% were considered "significant". Volume thresholds of 0.01, 0.03, 0.06, 0.09 and 0.12 cm(3) were utilised and Pearson's correlation coefficient (r) was calculated to correlate the calcium volume with percent stenosis. Results: Of 100 carotid bifurcations, 88 were available and of these 7 were significantly stenotic. The NECT calcium volume moderately correlated with percent stenosis on DSA r=0.53 (p<0.01). A moderate-strong correlation was found between the square root of calcium volume on NECT with percent stenosis on DSA (r=0.60, p<0.01). Via a receiver operating characteristic curve, 0.06 cm(3) was determined to be the best threshold (sensitivity 100%, specificity 90.1%, negative predictive value 100% and positive predictive value 46.7%) for detecting significant stenoses. Conclusion: This preliminary investigation confirms a correlation between carotid bifurcation calcium volume and percent ICA stenosis and is promising for the optimal threshold for stenosis detection. Future studies could utilise calcium volumes to create a "score" that could predict high grade stenosis.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: The bone tissue responses to Cyanoacrylate have been described in the literature, but none used N-butyl-2-cyanoacrilate (NB-Cn) for bone graft fixation. Purpose: The aims of the study were: (a) to analyze the bone grafts volume maintenance fixed either with NB-Cn or titanium screw; (b) to assess the incorporation of onlay grafts on perforated recipient bed; and (c) the differences of expression level of tartrate-resistant acid phosphatase (TRAP) protein involved in bone resorption. Materials and Methods: Eighteen New Zealand White rabbits were submitted to calvaria onlay grafting on both sides of the mandible. On one side, the graft was fixed with NB-Cn, while on the other hand the bone graft was secured with an osteosynthesis screw. The computed tomography (CT) was performed just after surgery and at animals sacrifice, after 1 (n = 9) and 6 weeks (n = 9), in order to estimate the bone grafts volume along the experiments. Histological sections of the grafted areas were prepared to evaluate the healing of bone grafts and to assess the expression of TRAP protein. Results: The CT scan showed better volume maintenance of bone grafts fixed with NB-Cn (p = 0.05) compared with those fixed with screws, in both experimental times (analysis of variance). The immunohistochemical evaluation showed that the TRAP expression in a 6-week period was significantly higher compared with the 1-week period, without showing significant difference between the groups (Wilcoxon and MannWhitney). Histological analysis revealed that the NB-Cn caused periosteum damage, but provided bone graft stabilization and incorporation similar to the control group. Conclusion: The perforation provided by screw insertion into the graft during fixation may have triggered early revascularization and remodeling to render increased volume loss compared with the experimental group. These results indicate that the NB-Cn possesses equivalent properties to titanium screw to be used as bone fixation material in osteosynthesis.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Coronary artery calcification (CAC) and low bone density are coexisting deleterious conditions commonly shared by chronic kidney disease (CKD) patients. In the present study, we aimed to investigate whether the progression of CAC was associated with overtime reduction in bone density in non-dialyzed CKD patients. Methods: This is a prospective study of 24 months including 72 non-dialyzed CKD patients Stages 2 - 4 (age 57.6 +/- 10.3 years, 62% male, 22% diabetics). CAC and vertebral bone density (VBD) were measured by computed tomography. Results: At baseline, 46% of the patients had CAC (calcified group) and calcification was not identified in 54% of the patients (non-calcified group). The calcified group was older, predominantly male, and had lower VBD in comparison to non-calcified group. CAC progression was observed only in the calcified group (91% of the patients increased calcium score). The multiple regression analysis revealed loss of VBD as the independent determinant of CAC progression in these patients. Conclusion: CAC progression was associated with loss of VBD in non-dialyzed CKD patients.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Abstract: Bisphosphonate-related osteonecrosis of the jaws (BRONJ) is characterized as exposed bone in the jaws for more than 8 weeks in patients with current or previous history of therapy with bisphosphonates (BPs) and no history of radiotherapy in the head and neck. We report a case series of 7 patients with BRONJ and analyze the variations of clinical and imaging signs, correlating them with the presence or absence of bone exposure. Among the patients, 6 were women and 1 was a man, aged 42–79 years. Five of the patients were using zoledronic acid and the other 2 alendronate. The use of BPs varied from 3 to 13 years. In 5 patients, tooth extraction was the triggering event of injuries. Panoramic radiographs and computed tomography (CT) were evaluated by a radiologist blinded to the cases. There were persistent unremodeled extraction socket even several months after tooth extraction in 3 of the cases that were consistent wit CT findings that also showed areas of osteosclerosis and osteolysis. Patients were treated according to the recommendations of the AAOMS, with surgical debridement and antibiotic coverage with amoxicillin in the symptomatic patients. The follow-up of these patients ranged from 8 to 34 months, with a good response to treatment. The image findings in this case series were not specific and showed no difference between each stages of BRONJ (AAOMS, 2009). The image features were similar in presence or absence of exposed bone.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objectives The aim of this study was to determine the prevalence of apical periodontitis (AP) detected in cone beam CT (CBCT) images from a database. Methods CBCT images of 300 Brazilian patients were assessed. AP images were measured in three dimensions. Age, gender, number and location of total teeth in each patient were considered. AP location was considered according to tooth groups. The extent of AP was determined by the largest diameter in any of the three dimensions. Percentages and the X2 test were used for statistical analysis. Results AP was found in 51.4% of the patients and in 3.4% of the teeth. Higher prevalence of AP was found in 60- to 69-year-olds (73.1%) and in mandibular molars (5.9%) (p < 0.05). Inadequate endodontic treatment presented higher prevalence of AP (78.1%). Conclusions AP can be frequently found in CBCT examinations. The presence of AP has a significant association with patients' age, and tooth type and condition. CBCT databases are useful for cross-sectional studies about AP prevalence in a population.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Despite the nomenclature suggested to be a tumor, torus palatinus (TP) is an overgrowth of the bone in the palatal region and represents an anatomic variation. Its prevalence varies among the population studied and its etiology is still unclear; however, it seems to be a multifactorial disorder with genetics and environmental involvement. Surgical removal of the TP is indicated in the following circumstances: (1) deglutition and speech impairment, (2) cancer phobia, (3) traumatized mucosa over the torus, and (4) prosthetic reasons. The aim of this case report is describe cases that occurred in two sisters, emphasizing the genetic etiology of this anatomic variation. In addition, intra-oral exam and computed tomography scan (axial, coronal and sagittal view) provided a detailed assessment of the TP and elimination of other possible diagnoses, furthermore allowed a better analyzes of the anatomic relation with adjacentes structures. No surgical removal was indicated for both cases.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: This study aimed to assess the presence of additional foramina and canals in the anterior palate region, through cone beam computed tomography (CBCT) images, describing their location, direction, and diameter. Materials & Methods: CBCT exams of 178 subjects displaying the anterior maxilla were included and the following parameters were registered: gender; age group; presence of additional foramina in the anterior palate (AFP) with at least 1 mm in diameter; location and diameter of AFP; and direction of bony canals associated with AFP. Results: Twenty-eight patients (15.7%) presented AFP and in total 34 additional foramina were registered. No statistical differences between patients with or without AFP were found for gender or age. The average diameter of AFP was 1.4 mm (range from 1 to 1.9 mm). Their location was variable, with most of the cases occurring in the alveolar process near the incisors or canines (n = 27). In 18 cases, AFP was associated with bony canals with upward or oblique direction toward the anterior nasal cavity floor. In 14 cases, the canal presented as a direct extension of the canalis sinuosus, in an upward direction laterally to the nasal cavity aperture. In two cases, the canal was observed adjacent to the incisive and joined the nasopalatine canal superiorly. Discussion: CBCT images have a crucial role in the recognition of anatomical variations by allowing detailed tridimensional evaluations. Additional foramina and canals in the anterior region of the upper jaw are relatively frequent. Practitioners should be aware and trained to identify these variations. Conclusions: Over 15% of the population studied had additional foramina in the anterior palate, between 1 mm and 1.9 mm wide, with variable locations. In most cases the canals associated with these foramina either presented as a direct extension of the canalis sinuosus, or coursed towards the nasal cavity floor.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objectives: The objective of this study is to compare subjective image quality and diagnostic validity of cone-beam CT (CBCT) panoramic reformatting with digital panoramic radiographs. Materials and methods: Four dry human skulls and two formalin-fixed human heads were scanned using nine different CBCTs, one multi-slice CT (MSCT) and one standard digital panoramic device. Panoramic views were generated from CBCTs in four slice thicknesses. Seven observers scored image quality and visibility of 14 anatomical structures. Four observers repeated the observation after 4 weeks. Results: Digital panoramic radiographs showed significantly better visualization of anatomical structures except for the condyle. Statistical analysis of image quality showed that the 3D imaging modalities (CBCTs and MSCT) were 7.3 times more likely to receive poor scores than the 2D modality. Yet, image quality from NewTom VGi® and 3D Accuitomo 170® was almost equivalent to that of digital panoramic radiographs with respective odds ratio estimates of 1.2 and 1.6 at 95% Wald confidence limits. A substantial overall agreement amongst observers was found. Intra-observer agreement was moderate to substantial. Conclusions: While 2D-panoramic images are significantly better for subjective diagnosis, 2/3 of the 3D-reformatted panoramic images are moderate or good for diagnostic purposes. Clinical relevance: Panoramic reformattings from particular CBCTs are comparable to digital panoramic images concerning the overall image quality and visualization of anatomical structures. This clinically implies that a 3D-derived panoramic view can be generated for diagnosis with a recommended 20-mm slice thickness, if CBCT data is a priori available for other purposes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Computed tomography (CT)-guided percutaneous drilling is an alternative for osteoid osteoma treatment. This study aims to evaluate the remodeling of the drill orifice. The success rate and complications were also recorded and compared with other treatment methods.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Patients with hydrocephalus and risk factors for overdrainage may be submitted to ventricular shunt (VS) implant with antisiphon device. The objective of this study was to prospectively evaluate for two years the clinical and tomographic results of the implant of fixed-pressure valves with antisiphon device SPHERA® in 35 adult patients, with hydrocephalus and risk factors for overdrainage. Of these, 3 had congenital hydrocephalus in adult patients with very dilated ventricles (Evans index >50%), 3 had symptomatic overdrainage after previous VS implant (subdural hematoma, hygroma or slit ventricle syndrome), 1 had previous chronic subdural hematoma, 15 had normal pressure hydrocephalus with final lumbar pressure <5 cm H2O after tap test (40 mL), 6 had pseudotumor cerebri, and 7 had hydrocephalus due to other causes. Clinical improvement was observed and sustained in 94.3% of the patients during the two-year period with no computed tomography (CT) evidence of hypo or overdrainage, and no immediate early or late significant complications.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJETIVO: Descrever os principais achados de imagem em uma série de casos de tumores neuroendócrinos primários do pulmão (TNPs), destacando as alterações na tomografia computadorizada. MATERIAIS E MÉTODOS: Exames de 22 pacientes (12 homens, idade média de 60 anos) avaliados nos últimos cinco anos em nosso serviço, com confirmação histopatológica, foram retrospectivamente revistos por dois médicos radiologistas e os achados foram descritos em consenso, focando as alterações tomográficas. RESULTADOS: Descrevemos 5 carcinoides típicos, 3 carcinoides atípicos, 3 carcinomas neuroendócrinos de grandes células (CNGCs) e 11 cânceres pulmonares de pequenas células (CPPCs). Apenas um carcinoide típico apresentou aspecto característico de nódulo endobrônquico central com atelectasia pulmonar distal, enquanto os demais foram nódulos ou massas pulmonares. Os carcinoides atípicos eram massas pulmonares periféricas e heterogêneas. Um CNGC era massa periférica delimitada e homogênea, enquanto os demais eram mal delimitados e heterogêneos. Os 11 CPPCs eram massas centrais, infiltrativas e heterogêneas, com alterações pleuropulmonares secundárias. Calcificações estavam ausentes nos CNGCs e CPPCs. Metástases foram vistas inicialmente ou no seguimento de todos os CNGCs e CPPCs. CONCLUSÃO: Apesar de alguns aspectos semelhantes nos exames de imagem, os achados radiológicos, quando integrados às informações clínicas, podem constituir critérios importantes na diferenciação dos tipos histológicos de TNPs.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Tumores miofibroblásticos inflamatórios raramente acometem vias urinárias ou crianças, comumente mimetizando neoplasias malignas nos exames de imagem. Foram descritos apenas 35 casos desses tumores na bexiga de crianças, segundo a literatura recente. Os autores apresentam o caso de uma criança com um tumor miofibroblástico vesical que evoluiu favoravelmente após ressecção cirúrgica completa.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJETIVO: Avaliar a PET/CT na abordagem de pacientes com câncer de cabeça e pescoço. MATERIAIS E MÉTODOS: Estudo retrospectivo de 63 prontuários e exames de PET/CT de pacientes com câncer de cabeça e pescoço. RESULTADOS: Foram encontradas alterações em 76% dos exames. Destes, 7 (11%) foram considerados falso-positivos, com SUV < 5,0. A PET/CT mostrou-se negativa em 15 situações (24%). Dos 14 casos nos quais se utilizou o exame para estadiamento, em 3 (22%) houve aumento no estadiamento. CONCLUSÃO: A PET/CT mostra-se como exame de potencial valor na rotina de avaliação de pacientes com câncer de cabeça e pescoço, entretanto, necessitamos de maior número de casos para definirmos protocolo de uso.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Although the diagnosis of Graves' orbitopathy is primarily made clinically based on laboratory tests indicative of thyroid dysfunction and autoimmunity, imaging studies, such as computed tomography, magnetic resonance imaging, ultrasound and color Doppler imaging, play an important role both in the diagnosis and follow-up after clinical or surgical treatment of the disease. Imaging studies can be used to evaluate morphological abnormalities of the orbital structures during the diagnostic workup when a differential diagnosis versus other orbital diseases is needed. Imaging may also be useful to distinguish the inflammatory early stage from the inactive stage of the disease. Finally, imaging studies can be of great help in identifying patients prone to develop dysthyroid optic neuropathy and therefore enabling the timely diagnosis and treatment of the condition, avoiding permanent visual loss. In this paper, we review the imaging modalities that aid in the diagnosis and management of Graves' orbitopathy, with special emphasis on the diagnosis of optic nerve dysfunction in this condition.