52 resultados para Root Canal Preparation


Relevância:

80.00% 80.00%

Publicador:

Resumo:

This in vitro study compared different ultrasonic vibration modes for intraradicular cast post removal. The crowns of 24 maxillary canines were removed, the roots were embedded in acrylic resin blocks, and the canals were treated endodontically. The post holes were prepared and root canal impressions were taken with self-cured resin acrylic. After casting, the posts were cemented with zinc phosphate cement. The samples were randomly distributed into 3 groups (n=8): G1: no ultrasonic vibration (control); G2: tip of the ultrasonic device positioned perpendicularly to core surface and close to the incisal edge; and G3: tip of the ultrasonic device positioned perpendicularly to core surface at cervical region, close to the line of cementation. An Enac OE-5 ultrasound unit with an ST-09 tip was used. All samples were submitted to the tensile test using an universal testing machine at a crosshead speed of 1 mm/min. Data were subjected to one-way ANOVA and Tukey's post-hoc tests (α=0.05). Mean values of the load to dislodge the posts (MPa) were: G1 = 4.6 (± 1.4) A; G2 = 2.8 (± 0.9) B, and G3= 0.9 (± 0.3) C. Therefore, the ultrasonic vibration applied with the tip of device close to the core's cervical area showed higher ability to reduce the retention of cast post to root canal.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this study was to evaluate in vivo the clinical applicability of two electronic apex locators (EALs) - Apex (Septodont) and iPex (NSK) - in different groups of human teeth by using radiography. The working lengths (WLs) of 100 root canals were determined electronically. The EAL to be used first was chosen randomly and a K-file was inserted into the root canal until the EAL display indicated the location of the apical constriction (0 mm). The K-file was fixed to the tooth and a periapical radiograph was taken using a radiographic film holder. The K-file was removed and the WL was measured. The same procedure was repeated using the other EAL. Radiographs were examined with the aid of a light-box with lens of ×4 magnification by two blinded experienced endodontists. The distance between the file tip and the root apex was recorded as follows: (A) +1 to 0 mm, (B) -0.1 to 0.5 mm, (C) -0.6 to 1 mm, (D) -1.1 to 1.5 mm, and (E) -1.6 mm or greater. For statistical purposes, these scores were divided into 2 subgroups according to the radiographic apex: acceptable (B, C, and D) and non-acceptable (A and E). Statistically significant differences were not found between the results of Apex and iPex in terms of acceptable and non-acceptable measurements (p>0.05) or in terms of the distance recorded from file tip and the radiographic apex (p>0.05). Apex and iPex EALs provided reliable measurements for WL determination for endodontic therapy.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Complete debridement with smear layer removal are essential measures for achieving a successful outcome of root canal treatment. The aim of this study was to evaluate the effects of chitosan at different concentrations on the removal of the smear layer and on dentin structure after 3 and 5 min of application. Twelve recently extracted maxillary canine teeth were instrumented using the crown-down technique and irrigated with 1% sodium hypochlorite. The specimens were distributed according to the time and concentration of the final irrigating solution: G1: 0.1% chitosan for 3 min; G2: 0.2% chitosan for 3 min; G3: 0.37% chitosan for 3 min; G4: 0.1% chitosan for 5 min; G5: 0.2% chitosan for 5 min; G6: 0.37% chitosan for 5 min. All samples were prepared for SEM analysis. G1 exhibited removal of the smear layer, but not the smear plugs. G2 showed visible and open tubules with slight erosion of the peritubular dentin. Cleaning in G3 was similar to that in G2, however, the erosive effect was greater. There was expansion of the diameter of the tubules in G4; and in G5 and G6, there was severe erosion with deterioration of dentin surface. In conclusion, 0.2% chitosan for 3 min appeared to be efficient for removing the smear layer, causing little erosion of dentin.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Besides the risk of filling material extrusion throughout the apex, a satisfactory apical seal can be difficult to achieve in canals with open apices or iatrogenic enlargements of the apical constriction. These situations pose a challenge to root canal filling. This paper describes the root canal filling of a maxillary right canine with an overinstrumented apex, complete loss of the apical stop, extensive canal transportation and apical periodontitis. A 5 mm calcium hydroxide apical plug was placed before root canal filling. The plug was made by soaking paper points with saline, dipping the points in calcium hydroxide powder and then applying it to the apex several times, until a consistent apical plug was obtained. The canal was then irrigated with saline in order to remove any residual calcium hydroxide from the root canal walls, dried with paper points and obturated with an inverted #80 gutta-percha cone and zinc oxide-eugenol based sealer by the lateral condensation technique. An 8-year radiographic follow-up showed formation of mineralized tissue sealing the apical foramen, apical remodeling and no signs of apical periodontitis.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: The aim of this study was to investigate the influence of cervical preflaring in determining the initial apical file (IAF) in the palatal roots of maxillary molars, and to determine the morphologic shape of the canal 1 mm short of the apex. METHODS: After preparing standard access cavities the group 1 received the IAF without cervical preflaring (WCP). In groups 2 to 5, preflaring was performed with Gates-Glidden (GG), Anatomic Endodontics Technology (AET), GT Rotary Files (GT) and LA Axxes (LA), respectively. Each canal was sized using manual K-files, starting with size 08 files, and making passive movements until the WL was reached. File sizes were increased until a binding sensation was felt at the WL. The IAF area and the area of the root canal were measured to verify the percentage occupied by the IAF inside the canal in each sample by SEM. The morphologic shape of the root canal was classified as circular, oval or flattened. Statistical analysis was performed by ANOVA/Tukey test (P < 0.05). RESULTS: The decreasing percentages occupied by the IAF inside the canal were: LA>GT=AET>GG>WCP. The morphologic shape was predominantly oval. CONCLUSION: The type of cervical preflaring used interferes in the determination of IAF.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Statement of problem: Since the introduction of glass fiber posts, irreversible vertical root fractures have become a rare occurrence; however, adhesive failure has become the primary failure mode. Purpose: The purpose of this study was to evaluate the push-out bond strength of glass fiber posts cemented with different luting agents on 3 segments of the root. Material and methods: Eighty human maxillary canines with similar root lengths were randomly divided into 8 groups (n=10) according to the cement assessed (Rely X luting, Luting and Lining, Ketac Cem, Rely X ARC, Biscem, Duo-link, Rely X U100, and Variolink II). After standardized post space preparation, the root dentin was pretreated for dualpolymerizing resin cements and untreated for the other cements. The mixed luting cement paste was inserted into post spaces with a spiral file and applied to the post surface that was seated into the canal. After 7 days, the teeth were sectioned perpendicular to their long axis into 1-mm-thick sections. The push-out test was performed at a speed of 0.5 mm/min until extrusion of the post occurred. The results were evaluated by 2-way ANOVA and the all pairwise multiple comparison procedures (Tukey test) (?=.05). Results: ANOVA showed that the type of interaction between cement and root location significantly influenced the push-out strength (P<.05). The highest push-out strength results with root location were obtained with Luting and Lining (S3) (19.5 ±4.9 MPa), Ketac Cem (S2) (18.6 ±5.5 MPa), and Luting and Lining (S1) (18.0 ±7.6 MPa). The lowest mean values were recorded with Variolink II (S1) (4.6 ±4.0 MPa), Variolink II (S2) (1.6 ±1.5 MPa), and Rely X ARC (S3) (0.9 ±1.1 MPa). Conclusions: Self-adhesive cements and glass ionomer cements showed significantly higher values compared to dual-polymerizing resin cements. In all root segments, dual-polymerizing resin cements provided significantly lower bond strength. Significant differences among root segments were found only for Duo-link cement.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Since instrumentation of the apical foramen has been suggested for cleaning and disinfection of the cemental canal, selection of the file size and position of the apical foramen have challenging steps. This study analyzed the influence of apical foramen lateral opening and file size can exert on cemental canal instrumentation. Thirty-four human maxillary central incisors were divided in two groups: Group 1 (n=17), without flaring, and Group 2 (n=17), with flaring with LA Axxess burs. K-files of increasing diameters were progressively inserted into the canal until binding at the apical foramen was achieved and tips were visible and bonded with ethyl cyanoacrylate adhesive. Roots/files set were cross-sectioned 5 mm from the apex. Apices were examined by scanning electron microscopy at ×140 and digital images were captured. Data were analyzed statistically by Student’s t test and Fisher’s exact test at 5% significance level. SEM micrographs showed that 19 (56%) apical foramina emerged laterally to the root apex, whereas 15 (44%) coincided with it. Significantly more difficulty to reach the apical foramen was noted in Group 2. Results suggest that the larger the foraminal file size, the more difficult the apical foramen instrumentation may be in laterally emerged cemental canals.