51 resultados para Ophthalmic surgery


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Two-millimeter punch biopsy is a swift and practical diagnostic tool in the outpatient setting. However, few studies have evaluated the efficacy of the method for diagnosis of malignant eyelid tumors. Methods: This was an observational study of patients with suspicion of malignant eyelid tumor attending the Ocular Plastic Surgery Center at Hospital das Clinicas, University of Sao Paulo School of Medicine. Following standard procedures, preoperative biopsies were taken with a 2-mm trephine and surgical excision was performed with safety margins, followed by reconstruction. Anatomopathologic analysis of the surgical specimen was used as gold standard to evaluate the accuracy of diagnosis by punch biopsy. Results: The study included 50 periocular tumors with suspicion of malignancy. The indicators of efficacy in the identification of malignancy by 2-mm punch biopsy were: sensitivity 88%, specificity 100%, positive predictive value 100%, and negative predictive value 64%. Accuracy was 90% for malignancy and 80% for histologic type. The. index of agreement between the diagnostic methods was 0.722 (p < 0.001). Conclusion: A positive result with 2-mm punch biopsy is a safe indication for surgical excision of the tumor, whereas a negative result does not necessarily imply benignity. In cases of high clinical suspicion, a second biopsy should be taken from a different part of the tumor to rule out malignancy. (Ophthal Plast Reconstr Surg 2012;28:282-285)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To quantify the risk of new diplopia in inferomedial orbital decompression performed for cosmetic reasons. Methods: Retrospective analysis of 114 patients with Graves orbitopathy who underwent an inferomedial orbital decompression. No patient had diplopia in any of the gaze positions or optic neuropathy. A single coronal slice 9 mm posterior to the lateral orbital rim was employed to quantify the muscular index of the extraocular recti and of the superior complex. A control group of 56 patients imaged for other reasons were also measured. After surgery the oculomotor status of all patients who complained of diplopia and of 51 patients free of diplopia was measured with the prism and cover test in the primary and secondary gaze positions. Results: The rate of new-onset diplopia was 14.0% (16 patients). Eye deviations were confirmed in 14 patients. Of these, 10 had significant strabismus that warranted surgical or prism treatment. Most patients had esotropia associated with small vertical deviations. The size of the medial and inferior recti was significantly associated with the development of diplopia. The estimated odds for the appearance of diplopia in patients with muscle enlargement was 12.76 (medial rectus) and 5.21 (inferior rectus). Small-angle deviations were also detected in 27.4% of patients who did not experience diplopia. Conclusions: Medial and inferior recti enlargement is a strong predictor of new-onset diplopia. A large number of patients who do not report diplopia also present with small-angle deviations. (Ophthal Plast Reconstr Surg 2012;28:204-207)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Evaluation of outcomes after aesthetic surgery still is a challenge in plastic surgery. The evaluation frequently is based on subjective criteria. This study used a new clinical grading scale to evaluate aesthetic results for plastic surgeries to the abdomen. The method scores each of the following five parameters: volume of subcutaneous tissue, contour, excess of skin, aspect of the navel, and quality of the scar on the abdominal wall. The scale options are 0 (poor), 1 (fair), and 2 (good), and the total rate can range from 0 to 10. The study included 40 women ages 18-53 years. Of these 40 women, 20 underwent traditional abdominoplasty, and 20 had liposuction alone. Preoperatively and at least 1 year later, photographic results were analyzed and scored by three independent plastic surgeons. In the abdominoplasty group, the average grade rose from 2.9 +/- A 0.4 to 6.8 +/- A 0.4 postoperatively. In the liposuction group, the average grade was 5.3 +/- A 0.5 preoperatively and 7.7 +/- A 0.4 postoperatively. In both groups, the average postoperative grade was significantly higher than the preoperative grade. The mean scores for groups A and L were significantly different, demonstrating that the scale was sensitive in identifying different anatomic abnormalities in the abdomen. The rating scale used for the aesthetic evaluation of the abdomen was effective in the analysis of two different procedures: conventional abdominoplasty and liposuction. Abdominoplasty provided the greater gain according to a comparison of the pre- and postoperative scores.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate biomechanical changes measured with the ORA (Ocular Response Analyzer (R); Reichert Ophthalmic Instruments, Buffalo, New York, USA) after Lasik with the Moria One Use Plus and to compare the biomechanics changes after myopic and hyperopic ablations. Methods: Fourteeneyes for hyperopia (H) and 19 eyes for myopia (M) were evaluated with the ORA preoperatively and 1 month after Lasik with thin flap (100 microns) using SBK-OUP (Sub-Bowman Keratomileusis-One Use Plus, Moria (R)). CH (Corneal Hysteresis), CRF (Corneal Resistance Factor), IOPg (gold-standard, Goldmann correlated Intraocular pressure), IOPcc (Corneal compensated Intraocular pressure) and more 38 variables derived from the corneal biomechanical response signal of the ORA were analyzed. The Wilcoxon test was used to assess differences between the variables before and after surgery for each group and the differences between the pre and postoperative (1 month) myopic eyes were compared with those obtained in hyperopic eyes, using the Mann-Whitney test. Results: There was a significant difference before and after Lasik in myopic and hyperopic eyes in IOPg (Wilcoxon, p<0.05), but not in IOPcc. Only myopic eyes showed a significant difference in CH and CRF measurements before and after LASIK, as well as 9 other biomechanical parameters (aspect1, h1, dive1, path1, p1area1, W11, H11, and w2 path11; Wilcoxon, p<0, 05), 8 of these being related to the first sign of flattening. Five parameters related to the sign of the second applanation showed significant variation only in the eyes before and after hyperopic Lasik (aspect2, h2, dive2, mslew2 and H21; Wilcoxon, p<0,05). There was a difference in both myopic and hyperopic on three parameters related to the applanation signal areas (p1area, and p2area p2area1; Wilcoxon, p<0.05). Differences in IOPg and p1area, before and after surgery were significantly higher in myopic eyes than in hyperopic eyes (Mann-Whitey, p<0.05). Conclusion: There are several significant differences in biomechanical parameters after Lasik with Moria OUP_SBK. Overall, the impact of myopic LASIK on corneal biomechanics is higher than of hyperopic Lasik. The parameters derived from the first sign of the ORA are more affected in myopic LASIK, whereas parameters derived from the second applanation are more affected in hyperopic LASIK.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 12-year-old girl had a 6-year history of a large soft-tissue mass in her left orbit. The tumor biopsy was previously performed elsewhere when she was 7 years old, but no treatment was offered at that time. Later, the tumor was completely excised, and histologic examination revealed a mesenchymal neoplasia with typical hemangiopericytoma features. At 9 months of follow up, no evidence of local recurrence or metastasis was seen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aims of this study were to evaluate the influence of cardiopulmonary bypass (CPB) on the plasma concentrations and pharmacokinetics of cefuroxime and to assess whether the cefuroxime dose regimen (a 1.5 g dose, followed by 750 mg every 6 h for 24 h) is adequate for cardiac surgery antibiotic prophylaxis. A prospective, controlled, observational study compared patients undergoing coronary surgery with CPB (CPB group, n = 10) or off-pump surgery (off-pump group, n = 9). After each cefuroxime dose, blood samples were sequentially collected and analysed using high-efficiency chromatography. For demographic data and pharmacokinetic parameters, the authors used Fisher's exact test for nominal variables and Student's t-test and the Mann-Whitney U-test for parametric and non-parametric variables, respectively. Plasma concentrations were compared using ANOVA, and the percentage of patients with a remaining plasma concentration of > 16 mg/l within 6 h after each bolus was quantified in tabular form. After each cefuroxime bolus was administered, both groups presented a significant decrease in plasma concentration over time (P < 0.001), without differences between the groups. The mean CPB time of 59.7 +/- 21.1 min did not change cefuroxime plasma concentrations or pharmacokinetics. The mean clearance +/- SD (ml/kg/min) and median elimination half-life (h) of the CPB group versus the off-pump group were 1.7 +/- 0.7 versus 1.6 +/- 0.6 (P = 0.67), respectively, and 2.2 versus 2.3 (P = 0.49), respectively. Up to 3 h following the first bolus of 1.5 g, but not after 6 h, all patients had plasma concentrations > 16 mg/l (CPB group = 20% and off-pump group = 44%). However, after all 750 mg boluses were administered, concentrations < 16 mg/dl were reached within 3 h. CPB does not influence cefuroxime plasma concentrations. The dosing regimen is adequate for the intraoperative period, but in the immediate postoperative period, it requires further review.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background-The Second Medicine, Angioplasty, or Surgery Study (MASS II) included patients with multivessel coronary artery disease and normal systolic ventricular function. Patients underwent coronary artery bypass graft surgery (CABG, n = 203), percutaneous coronary intervention (PCI, n = 205), or medical treatment alone (MT, n = 203). This investigation compares the economic outcome at 5-year follow-up of the 3 therapeutic strategies. Methods and Results-We analyzed cumulative costs during a 5-year follow-up period. To analyze the cost-effectiveness, adjustment was made on the cumulative costs for average event-free time and angina-free proportion. Respectively, for event-free survival and event plus angina-free survival, MT presented 3.79 quality-adjusted life-years and 2.07 quality-adjusted life-years; PCI presented 3.59 and 2.77 quality-adjusted life-years; and CABG demonstrated 4.4 and 2.81 quality-adjusted life-years. The event-free costs were $9071.00 for MT; $19 967.00 for PCI; and $18 263.00 for CABG. The paired comparison of the event-free costs showed that there was a significant difference favoring MT versus PCI (P<0.01) and versus CABG (P<0.01) and CABG versus PCI (P<0.01). The event-free plus angina-free costs were $16 553.00, $25 831.00, and $24 614.00, respectively. The paired comparison of the event-free plus angina-free costs showed that there was a significant difference favoring MT versus PCI (P=0.04), and versus CABG (P<0.001); there was no difference between CABG and PCI (P>0.05). Conclusions-In the long-term economic analysis, for the prevention of a composite primary end point, MT was more cost effective than CABG, and CABG was more cost-effective than PCI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Bariatric surgery influences the intake and absorption of nutrients. The serum concentrations of vitamin C, myeloperoxidase (MPO) and oral clinical manifestations were examined in patients two years after Roux-en-Y gastric bypass (RYGB). Methods: Clinical prospective-study with control-group (CG; n = 26), assessed only once, and the bariatric-group (BG; n = 26), assessed in the basal period and at 12 and 24 months after surgery. The mean ages in the CG and BG were 37.8 +/- 1.51 and 39.6 +/- 1.93 years, respectively, and their body mass indices were 22.07 +/- 0.29 and 45.62 +/- 1.46 kg/m2, respectively. Results: At 12 months after surgery, increased episodes of vomiting (P < .001) and dental hypersensitivity (P=.012) were observed, with a reduction in the saliva buffering capacity of 21.3 2.9% (P=.004). At 24 months after RYGB, we detected a significant reduction in serum vitamin C (32.9 +/- 5.3%, P < .001) and MPO values were higher than in the basal period (P = .032). With regard to oral hygiene habits, 92.3% of patients reported frequent tooth brushing and 96.1% used fluoride, which were similar across the two years. However, dental hypersensitivity (P = .048) was significantly increased than baseline. Conclusions: The results demonstrated that vitamin C deficiency and increased vomiting after RYGB for morbid obesity may contribute to increased periodontal disease. The fact it is impossible to determine which factors (diet, poor compliance with supplementation, vomiting, poor oral hygiene) contributed to the dental problems in these patients is a shortcoming of the report. (Nutr Clin Pract. 2012; 27: 114-121)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Brilliant blue G (BBG) is frequently used in chromovitrectomy to facilitate internal limiting membrane (ILM) peeling. A study was initiated to evaluate if heavy BBG is safe and effective in staining the ILM. Methods: We studied 30 eyes, 23 with idiopathic macular holes and 7 of patients with diabetic macular edema. Removal of the ILMs was assisted by heavy BBG staining. In cases with histopathological correlation the ILMs were evaluated with hematoxylin and eosin, Masson's trichrome, periodic acid-Schiff and glial fibrillary acidic protein staining. In addition, immunohistochemistry was also performed using specific antibodies for vimentin, neuron-specific enolase, factor VIII and CD68. Using the Image-Pro Plus software of Media Cybernetics Co. we found an average thickness in ILMs. Results: Of the ILM specimens sent, 19/30(63.33%) could not be processed properly because of the limited sample material, recognizing only fragments of dispersed fibrillar material. In macular hole ILMs we found an average thickness of 1.3 +/- 0.65 mu m, and in diabetic macular edema ILMs an average thickness of 6.2 +/- 1.4 mu m. Conclusions: In heavy BBG-assisted ILM peeling we observed no intraoperative or postoperative complications after a mean follow-up of 12 months. Heavy BBG could be an effective and safe vehicle for staining the ILM. Copyright (C) 2012 S. Karger AG, Basel

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The pathophysiology of acute coronary syndromes (ACS) after noncardiac surgery is not established yet. Thrombosis over a vulnerable plaque or decreased oxygen supply secondary to anemia or hypotension may be involved. The purpose of this study was to investigate the pathophysiology of ACS complicating noncardiac surgery. Methods: Clinical and angiographic data were prospectively recorded into a database for 120 consecutive patients that had an ACS after noncardiac surgery (PACS), for 120 patients with spontaneous ACS (SACS), and 240 patients with stable coronary artery disease (CAD). Coronary lesions with obstructions greater than 50% were classified based on two criteria: Ambrose's classification and complex morphology. The presence of Ambrose's type II or complex lesions were compared between the three groups. Results: We analyzed 1470 lesions in 480 patients. In PACS group, 45% of patients had Ambrose's type II lesions vs. 56.7% in SACS group and 16.4% in stable CAD group (P < 0.001). Both PACS and SACS patients had more complex lesions than patients in stable CAD group (56.7% vs. 79.2% vs. 31.8%, respectively; P < 0.001). Overall, the independent predictors of plaque rupture were being in the group PACS (P < 0.001, OR 2.86; CI, 1.82-4.52 for complex lesions and P < 0.001, OR 3.43; CI, 2.1-5.6 for Ambrose's type II lesions) or SACS (P < 0.001, OR 8.71; CI, 5.15-14.73 for complex lesions and P < 0.001, OR 5.99; CI, 3.66-9.81 for Ambrose's type II lesions). Conclusions: Nearly 50% of patients with perioperative ACS have evidence of coronary plaque rupture, characterizing a type 1 myocardial infarction. (C) 2012 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. The aim of this study was to evaluate the need for antibiotic prescription in third molar surgery. Study design. A double-blind randomized study was carried out with 71 patients from CODONT (Dentistry Center of the Police of Sao Paulo). Amoxicillin, clindamycin, or no medication was administered for 7 days immediately after surgery. The participants evaluated the presence of pain, edema, interincisal distance (ID), presence of infection, Pell and Gregory classification, rescue analgesia, osteotomy, and odontosection. Results. There was no difference (P < .05) between antibiotics and control over the surgery duration, dose, visual analog scale (VAS), ID, and edema, yet significant differences were seen over time for VAS, edema, and ID. Conclusions. Antibiotic prescription should not be indicated in all clinical conditions, yet it is necessary to correctly evaluate factors such as systemic condition of the patient, skill of the operator, and contamination of the surgical environment. (Oral Surg Oral Med Oral Pathol Oral Radiol 2012; 114(suppl 5):S26-S31)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Background High astigmatisms are usually induced during corneal suturing subsequent to tissue transplantation or any other surgery which involves corneal suturing. One of the reasons is that the procedure is intimately dependent on the surgeon's skill for suturing identical stitches. In order to evaluate the influence of the irregularity on suturing for the residual astigmatism, a prototype for ophthalmic surgical support has been developed. The final intention of this prototype is to be an evaluation tool for guided suture and as an outcome diminish the postoperative astigmatism. Methods The system consists of hand held ring with 36 infrared LEDs, that is to be projected onto the lachrymal film of the cornea. The image is reflected back through the optics of the ocular microscope and its distortion from the original circular shape is evaluated by developed software. It provides keratometric and circularity measurements during surgery in order to guide the surgeon for uniformity in suturing. Results The system is able to provide up to 23D of astigmatism (32D - 55D range) and is ± 0.25D accurate. It has been tested in 14 volunteer patients intraoperative and has been compared to a commercial keratometer Nidek Oculus Hand-held corneal topographer. The correlation factors are 0.92 for the astigmatism and 0.97 for the associated axis. Conclusion The system is potentially efficient for guiding the surgeon on uniformity of suturing, presenting preliminary data indicating an important decrease on the residual astigmatism, from an average of 8D - for patients not submitted to the prototype guidance - to 1.4D - for patients who have actually been submitted to the prototype guidance - after the first 24 hours post-surgery and in the subsequent weeks. It also indicates that the surgeon should achieve circularity greater or equal to 98% in order to avoid postoperative astigmatisms over 1D. Trial Registration Trial registration number: CAAE - 0212.0.004.000-09.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Background Measurement of vital capacity (VC) by spirometry is the most widely used technique for lung function evaluation, however, this form of assessment is costly and further investigation of other reliable methods at lower cost is necessary. Objective: To analyze the correlation between direct vital capacity measured with ventilometer and with incentive inspirometer in patients in pre and post cardiac surgery. Methodology Cross-sectional comparative study with patients undergoing cardiac surgery. Respiratory parameters were evaluated through the measurement of VC performed by ventilometer and inspirometer. To analyze data normality the Kolmogorov-Smirnov test was applied, for correlation the Pearson correlation coefficient was used and for comparison of variables in pre and post operative period Student's t test was adopted. We established a level of ignificance of 5%. Data was presented as an average, standard deviation and relative frequency when needed. The significance level was set at 5%. Results We studied 52 patients undergoing cardiac surgery, 20 patients in preoperative with VC-ventilometer: 32.95 ± 11.4 ml/kg and VC-inspirometer: 28.9 ± 11 ml/Kg, r = 0.7 p < 0.001. In the post operatory, 32 patients were evaluated with VC-ventilometer: 28.27 ± 12.48 ml/kg and VC-inspirometer: 26.98 ± 11 ml/Kg, r = 0.95 p < 0.001. Presenting a very high correlation between the evaluation forms studied. Conclusion There was a high correlation between DVC measures with ventilometer and incentive spirometer in pre and post CABG surgery. Despite this, arises the necessity of further studies to evaluate the repercussion of this method in lowering costs at hospitals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Review paper and Proceedings of the Inaugural Meeting of the Head and Neck Optical Diagnostics Society (HNODS) on March 14th 2009 at University College London.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The complete surgical removal of disease is a desirable outcome particularly in oncology. Unfortunately much disease is microscopic and difficult to detect causing a liability to recurrence and worsened overall prognosis with attendant costs in terms of morbidity and mortality. It is hoped that by advances in optical diagnostic technology we could better define our surgical margin and so increase the rate of truly negative margins on the one hand and on the other hand to take out only the necessary amount of tissue and leave more unaffected non-diseased areas so preserving function of vital structures. The task has not been easy but progress is being made as exemplified by the presentations at the 2nd Scientific Meeting of the Head and Neck Optical Diagnostics Society (HNODS) in San Francisco in January 2010. We review the salient advances in the field and propose further directions of investigation.