36 resultados para LED light calibration system


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract Background Accurate malaria diagnosis is mandatory for the treatment and management of severe cases. Moreover, individuals with asymptomatic malaria are not usually screened by health care facilities, which further complicates disease control efforts. The present study compared the performances of a malaria rapid diagnosis test (RDT), the thick blood smear method and nested PCR for the diagnosis of symptomatic malaria in the Brazilian Amazon. In addition, an innovative computational approach was tested for the diagnosis of asymptomatic malaria. Methods The study was divided in two parts. For the first part, passive case detection was performed in 311 individuals with malaria-related symptoms from a recently urbanized community in the Brazilian Amazon. A cross-sectional investigation compared the diagnostic performance of the RDT Optimal-IT, nested PCR and light microscopy. The second part of the study involved active case detection of asymptomatic malaria in 380 individuals from riverine communities in Rondônia, Brazil. The performances of microscopy, nested PCR and an expert computational system based on artificial neural networks (MalDANN) using epidemiological data were compared. Results Nested PCR was shown to be the gold standard for diagnosis of both symptomatic and asymptomatic malaria because it detected the major number of cases and presented the maximum specificity. Surprisingly, the RDT was superior to microscopy in the diagnosis of cases with low parasitaemia. Nevertheless, RDT could not discriminate the Plasmodium species in 12 cases of mixed infections (Plasmodium vivax + Plasmodium falciparum). Moreover, the microscopy presented low performance in the detection of asymptomatic cases (61.25% of correct diagnoses). The MalDANN system using epidemiological data was worse that the light microscopy (56% of correct diagnoses). However, when information regarding plasma levels of interleukin-10 and interferon-gamma were inputted, the MalDANN performance sensibly increased (80% correct diagnoses). Conclusions An RDT for malaria diagnosis may find a promising use in the Brazilian Amazon integrating a rational diagnostic approach. Despite the low performance of the MalDANN test using solely epidemiological data, an approach based on neural networks may be feasible in cases where simpler methods for discriminating individuals below and above threshold cytokine levels are available.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: In epidemiological surveys, a good reliability among the examiners regarding the caries detection method is essential. However, training and calibrating those examiners is an arduous task because it involves several patients who are examined many times. To facilitate this step, we aimed to propose a laboratory methodology to simulate the examinations performed to detect caries lesions using the International Caries Detection and Assessment System (ICDAS) in epidemiological surveys. Methods: A benchmark examiner conducted all training sessions. A total of 67 exfoliated primary teeth, varying from sound to extensive cavitated, were set in seven arch models to simulate complete mouths in primary dentition. Sixteen examiners (graduate students) evaluated all surfaces of the teeth under illumination using buccal mirrors and ball-ended probe in two occasions, using only coronal primary caries scores of the ICDAS. As reference standard, two different examiners assessed the proximal surfaces by direct visual inspection, classifying them in sound, with non-cavitated or with cavitated lesions. After, teeth were sectioned in the bucco-lingual direction, and the examiners assessed the sections in stereomicroscope, classifying the occlusal and smooth surfaces according to lesion depth. Inter-examiner reproducibility was evaluated using weighted kappa. Sensitivities and specificities were calculated at two thresholds: all lesions and advanced lesions (cavitated lesions in proximal surfaces and lesions reaching the dentine in occlusal and smooth surfaces). Conclusion: The methodology purposed for training and calibration of several examiners designated for epidemiological surveys of dental caries in preschool children using the ICDAS is feasible, permitting the assessment of reliability and accuracy of the examiners previously to the survey´s development.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The two main tools to determine the dynamical and physical parameters of exoplanet systems are the radial velocity (RV) measurements and, when available, transit timings. The two techniques are complementary: The RV's allow us to know some of the orbital elements while the transit timings allow us to obtain the orbital inclination and planetary radius, impossible of obtain from the RV, and to resolve the indetermination in the determination of the planet mass from the RV's. The space observation of transiting planets is however not limited to transit times. They extend to long periods of time and are precise enough to provide information on variations along the orbit. Besides the effects of stellar rotation, deserve mention the Doppler shift in the radiation flux, as consequence of stellar movement around the center of mass, or Beaming Effect (BE); the Ellipsoidal Variability (EV) due to the tidal deformation of the star due to the gravitation of its close companion; and the Reflection (ER) of the stellar radiation incident on the planet and re-emitted to the observer. In the case of large hot Jupiters, these effects are enhanced by the strong gravitational interaction and the analysis of the light variation allows us independent estimates of the mass and radius of planet. The planetary system CoRoT 3 is favorable for such analysis. In this case, the secondary is a brown dwarf whose mass is of the order of 22Mj. We show results obtained from the analysis of 35 RV measurements, 236999 photometric observations and 11 additional RV observations made during a transit to determine the star rotation via the Rossiter-McLaughlin effect. The results obtained from this determination are presented in this communication. The results are compared to those resulting from other determinations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The continental margin off SE South America hosts one of the world’s most energetic hydrodynamic regimes but also the second largest drainage system of the continent. Both, the ocean current system as well as the fluvial runoff are strongly controlled by the atmospheric circulation modes over the region. The distribution pattern of particular types of sediments on shelf and slope and the long-term built-up of depositional elements within the overall margin architecture are, thus, the product of both, seasonal to millennial variability as well as long-term environmental trends. This talk presents how the combination of different methodological approaches can be used to obtain a comprehensive picture of the variability of a shelf and upper-slope hydrodynamic system during Holocene times. The particular methods applied are: (a) Margin-wide stratigraphic information to elucidate the role of sea level for the oceanographic and sedimentary systems since the last glacial maximum; (b) Palaeoceanographic sediment proxies combined with palaeo-temperature indicating isotopes of bivalve shells to trace lateral shifts in the coastal oceanography (particularly of the shelf front) during the Holocene; (c) Neodymium isotopes to identify the shelf sediment transport routes resulting from the current regime; (d) Sedimentological/geochemical data to show the efficient mechanism of sand export from the shelf to the open ocean; (e) Diatom assemblages and sediment element distributions indicating palaeo-salinity and the changing marine influence to illustrate the Plata runoff history. Sea level has not only controlled the overall configuration of the shelf but also the position of the main sediment routes from the continent towards the ocean. The shelf front has shifted frequently since the last glacial times probably resulting from both, changes in the Westerly Winds intensity and in the shelf width itself. Remarkable is a southward shift of this front during the past two centuries possibly related to anthropogenic influences on the atmosphere. The oceanographic regime with its prominent hydrographic boundaries led to a clear separation of sedimentary provinces since shelf drowning. It is especially the shelf front which enhances shelf sediment export through a continuous high sand supply to the uppermost slope. Finally, the Plata River does not continuously provide sediment to the shelf but shows significant climate-related changes in discharge during the past centuries. Starting from these findings, three major fields of research should, in general, be further developed in future: (i) The immediate interaction of the hydrodynamic and sedimentary systems to close the gaps between deposit information and modern oceanographic dynamics; (ii) Material budget calculations for the marginal ocean system in terms of material fluxes, storage/retention capacities, and critical thresholds; (iii) The role of human activity on the atmospheric, oceanographic and solid material systems to unravel natural vs. anthropogenic effects and feedback mechanisms

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Light Steel Framing building technology was introduced in Brazil in the late 1990s for the construction of residential houses. Because the design system was imported from the United States and is optimised to work well in that temperate climate, some modi fi cations must be made to adapt it for the Brazilian climate. The objective of this paper was to assess the impact of thermal bridging across enclosure elements on the thermal performance of buildings designed with Light Steel Framing in Brazil. The numerical simulation program EnergyPlus and a speci fi c method that considered the effects of metallic structures in the hourly simulations were used for the analysis. Two air-conditioned commercial buildings were used as case studies. The peak thermal load increased approximately 10% when an interior metal frame was included in the numerical simulations compared to non-metallic structures. Even when a metal frame panel was used only for vertical elements in the facade of a building with a conventional concrete structure, the simulations showed a 5% increase in annual energy use.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to evaluate the compressive strength of microhybrid (FiltekTM Z250) and nanofilled (FiltekTM Supreme XT) composite resins photo-activated with two different light guide tips, fiber optic and polymer, coupled with one LED. The power density was 653 mW cm-2 when using the fiber optic light tip and 596 mW cm-2 with the polymer. After storage in distilled water at 37± 2 °C for seven days, the samples were subjected to mechanical testing of compressive strength in an EMIC universal mechanical testing machine with a load cell of 5 kN and speed of 0.5 mm min-1. The statistical analysis was performed using ANOVA with a confidence interval of 95% and Tamhane’s test. The results showed that the mean values of compressive strength were not influenced by the different light tips (p > 0.05). However, a statistical difference was observed (p < 0.001) between the microhybrid composite resin photo-activated with the fiber optic light tip and the nanofilled composite resin. Based on these results, it can be concluded that microhybrid composite resin photo-activated with the fiber optic light tip showed better results than nanofilled, regardless of the tip used, and the type of the light tip did not influence the compressive strength of either composite. Thus, the presented results suggest that both the fiber optic and polymer light guide tips provide adequate compressive strength to be used to make restorations. However, the fiber optic light tip associated with microhybrid composite resin may be an interesting option for restorations mainly in posterior teeth.