80 resultados para Computed Tomography


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The cranial anatomy of Dinilysia patagonica, a terrestrial snake from the Upper Cretaceous of Argentina, is redescribed and illustrated, based on high-resolution X-ray computed tomography and better preparations made on previously known specimens, including the holotype. Previously unreported characters reinforce the intriguing mosaic nature of the skull of Dinilysia, with a suite of plesiomorphic and apomorphic characters with respect to extant snakes. Newly recognized plesiomorphies are the absence of the medial vertical flange of the nasal, lateral position of the prefrontal, lizard-like contact between vomer and palatine, floor of the recessus scalae tympani formed by the basioccipital, posterolateral corners of the basisphenoid strongly ventrolaterally projected, and absence of a medial parietal pillar separating the telencephalon and mesencephalon, amongst others. We also reinterpreted the structures forming the otic region of Dinilysia, confirming the presence of a crista circumfenestralis, which represents an important derived ophidian synapomorphy. Both plesiomorphic and apomorphic traits of Dinilysia are treated in detail and illustrated accordingly. Results of a phylogenetic analysis support a basal position of Dinilysia, as the sister-taxon to all extant snakes. The fossil taxa Yurlunggur, Haasiophis, Eupodophis, Pachyrhachis, and Wonambi appear as derived snakes nested within the extant clade Alethinophidia, as stem-taxa to the crown-clade Macrostomata. The hypothesis of a sister-group relationship between Dinilysia and Najash rionegrina, as suggested by some authors, is rejected by the results of our analysis.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

At times in clinical neurology, the identification of a subtle clinical or radiological sign can lead to prompt diagnosis of a very rare or difficult case. We report on a patient who presented with untreatable headache and unilateral ptosis. Computed tomography (CT) scan of the head did not reveal any structural cause. Magnetic resonance angiogram showed absence of left internal carotid artery, which was eventually confirmed by a catheter angiography. Reviewing the case, it emerged that a feature on the initial CT scan "bone window" would have confirmed the diagnosis, had it been searched for: the underdeveloped carotid canal, which is a consequence and a marker of internal carotid artery agenesis.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: This ex vivo study evaluated the effect of pre-flaring and file size on the accuracy of the Root ZX and Novapex electronic apex locators (EALs). Material and methods: The actual working length (WL) was set 1 mm short of the apical foramen in the palatal root canals of 24 extracted maxillary molars. The teeth were embedded in an alginate mold, and two examiners performed the electronic measurements using #10, #15, and #20 K-files. The files were inserted into the root canals until the "0.0" or "APEX" signals were observed on the LED or display screens for the Novapex and Root ZX, respectively, retracting to the 1.0 mark. The measurements were repeated after the pre-flaring using the S1 and SX Pro-Taper instruments. Two measurements were performed for each condition and the means were used. Intra-class correlation coefficients (ICCs) were calculated to verify the intra-and inter-examiner agreement. The mean differences between the WL and electronic length values were analyzed by the three-way ANOVA test (p<0.05). Results: ICCs were high (>0.8) and the results demonstrated a similar accuracy for both EALs (p>0.05). Statistically significant accurate measurements were verified in the pre-flared canals, except for the Novapex using a #20 K-file. Conclusions: The tested EALs showed acceptable accuracy, whereas the pre-flaring procedure revealed a more significant effect than the used file size.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of the present study was to test the reproducibility, sensitivity, and specificity of cone-beam computed tomography (CBCT) in detecting incipient furcation involvement. Fifteen macerated pig mandibles, with intact second molar teeth and preserved adjacent cortical areas, were used. Simulated lesions were created in the furcation region of these teeth by applying 70% perchloric acid in up to four possible buccal/lingual sites in the right/left sides of each mandible. The mandibles were then submitted to a CBCT scan. Two blinded and calibrated experienced oral and maxillofacial radiologists interpreted the exams. Furcation involvement was also assessed in the regions without simulated lesions. CBCT showed high levels of accuracy, ranging from 78% to 88%. The variations in Kappa values for intra- and inter-observer agreement (0.41-0.59) were considered moderate. CBCT can be considered a reliable and accurate method for detecting incipient furcation involvement.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The objective of the current study was to assess the outcome of the alveolar bone grafting (ABG) in patients with cleft palate. Thirty-one patients with complete unilateral cleft lip and palate were prospectively divided into 2 groups according to the timing of surgery: (1) secondary ABG (SABG), undertaken during mixed dentition (n = 16); and (2) tertiary ABG (TABG), undertaken during permanent dentition (n = 15). Septum height was assessed using cone beam computed tomography in 3 views (buccal, intermediate, palatal) and classified according to the modified Bergland Index, which scores the results into 5 types according to the height of the neoformed bone septum (excellent: septum with a normal height; good: septum with minor deficiency; regular: marginal defect of >25% of the root length; bad: bone deficiency on the nasal aspect; and failure). In the SABG group, 6 to 12 months postoperatively, 75% of the patients were classified as having excellent/good conditions and 25% as having regular/bad conditions. No patients were observed as having failure conditions. In the TABG group, 53% of the patients were classified as having excellent/good, 21% were classified as having regular/bad conditions, and 26% were classified as having failure conditions. Significantly better outcomes were observed for the SABG group when compared with the TABG group. In conclusion, the age at which ABG is performed is a factor that impacts on the surgical outcome. Specifically, increasing age is associated with worse outcomes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: There are several techniques for screw insertion in upper cervical spine surgery, and the use of the 3.5-mm screw is usually the standard. However, there is no consensus regarding the feasibility of using these screws in the pediatric population. OBJECTIVE: To determine the measurement of the lamina angle, lamina and pedicle length and thickness, and lateral mass length of the topographic axial view of the axis vertebra of 2- to 10-year-old children to guide the use of surgical screws. METHODS: Seventy-five computed tomography scans from 24- to 120-month-old patients were studied. Measurements were taken in an axial view of C2 and correlated with 2 age groups and both sexes. Statistical analysis was performed with the Student t test. RESULTS: In the 24- to 48-month age group, only 5.5% of the lamina and 8.3% of the pedicles had thicknesses < 3.5 mm. In the 49- to 120-month age group, there were no lamina thickness values < 3.5 mm, and 1.2% of pedicle thicknesses were < 3.5 mm. Both age groups had no lamina and pedicle lengths < 12 mm and no lateral mass lengths > 12 mm. CONCLUSION: In the majority of cases, the use of 3.5-mm lamina and pedicle screws in children is feasible. A base value of 45 degrees for the spinolaminar angle can be adopted as a reference for insertion of screws in the C2 lamina. This information can be particularly useful for decision making during preoperative planning for C1-C2 or craniocervical arthrodesis in children.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

There are many infectious complications related to vascular access in patients undergoing maintenance hemodialysis. We report two cases of endophthalmitis as a metastatic infection associated with a tunneled catheter and a temporary dual lumen catheter. Both patients were diabetic. A 61-year-old female on maintenance hemodialysis by a jugular tunnelized catheter during the past year was receiving parenteral antibiotics for catheter salvage due to fever episodes in the last 3 months. She was admitted to the hospital presenting pain, proptosis, conjunctival hyperemia, corneal infiltrate, and visual acuity of no light perception (NLP). A 51-year-old male recently undergoing hemodialysis by a temporary dual lumen catheter presented fever. His catheter was removed, but he was admitted to the hospital presenting fever, decreased vision, edema, and pain in his left eye. On examination, eyelid edema, conjunctival hyperemia, purulent secretion, hypopyon in the pupils, and visual acuity of NLP were verified. A diagnosis of endogenous endophthalmitis was made in both patients on clinical grounds and computed tomography. Evisceration of the left eye was the first option of treatment for both patients due to poor vision. Cultures of the eviscerated ocular globes showed Staphylococcus hemolyticus and Staphylococcus aureus, respectively. After evisceration, both patients received treatment, had a good outcome, and were discharged to continue their hemodialysis program. Metastatic bacterial endophthalmitis is a rare complication of dialysis catheter-related bacteremia. When suspected, urgent ophthalmologic evaluation and treatment are needed to reduce the risk of losing vision in the affected eye.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Postoperative pelvic abscesses in patients submitted to colorectal surgery are challenging. The surgical approach may be too risky, and image-guided drainage often is difficult due to the complex anatomy of the pelvis. This article describes novel access for drainage of a pelvic collection using a minimally invasive natural orifice approach. A 37 year-old man presented with sepsis due to a pelvic abscess during the second postoperative week after a Hartmann procedure due to perforated rectal cancer. Percutaneous drainage was determined by computed tomography to be unsuccessful, and another operation was considered to be hazardous. Because the pelvic fluid was very close to the rectal stump, transrectal drainage was planned. The rectal stump was opened using transanal endoscopic microsurgery (TEM) instruments. The endoscope was advanced through the TEM working channel and the rectal stump opening, accessing the abdominal cavity and pelvic collection. The pelvic collection was endoscopically drained and the local cavity washed with saline through the scope channel. A Foley catheter was placed in the rectal stump. The patient's recovery after the procedure was successful, without the need for further intervention. Transrectal endoscopic drainage may be an option for selected cases of pelvic fluid collection in patients submitted to Hartmann's procedure. The technique allows not only fluid drainage but also visualization of the local cavity, cleavage of multiloculated abscesses, and saline irrigation if necessary. The use of TEM instrumentation allows safe access to the peritoneal cavity.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: To carry out an anatomical study of the axis with the use of computed tomography (CT) in children aged from two to ten years, measuring the lamina angle, lamina and pedicle length and thickness, and lateral mass length. Methods: Sixty-four CTs were studied from patients aged 24 to 120 months old, of both sexes and without any cervical anomaly. The measurements obtained were correlated with the data on age and sex of the patients. Statistical analysis was performed using the Students "t" tests. Results: We found that within the age range 24-48 months, 5.5% of the lamina and 8.3% of the pedicles had thicknesses of less than 3.5mm, which is the minimum thickness needed for insertion of the screw. Between 49 and 120 months, there were no lamina thicknesses of less than 3.5mm, and 1.2% of the pedicle thicknesses were less than 3.5mm values. Neither of the age groups had any lamina and pedicle lengths of less than 12mm, or lateral mass lengths greater than 12mm. Conclusion: The analysis of the data obtained demonstrates that most of the time, is possible to use a 3.5mm pedicle screw in the laminas and pedicles of the axis in children. Level of Evidence: II, Development of diagnostic criteria in consecutive patients.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Several pancreatic diseases may require surgical treatment, with most of these procedures classified as resection or drainage. Resection procedures, which are usually performed to remove pancreatic tumors, include pancreatoduodenectomy, central pancreatectomy, distal pancreatectomy, and total pancreatectomy. Drainage procedures are usually performed to treat chronic pancreatitis after the failure of medical therapy and include the Puestow and Frey procedures. The type of surgery depends not only on the patient's symptoms and the location of the disease, but also on the expertise of the surgeon. Radiologists should become familiar with these surgical procedures to better understand postoperative changes in anatomic findings. Multidetector computed tomography is the modality of choice for identifying normal findings after surgery, postoperative complications, and tumor recurrence in patients who have undergone pancreatic surgery. (C)RSNA, 2012 . radiographics.rsna.org

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To estimate the metabolic activity of rectal cancers at 6 and 12 weeks after completion of chemoradiation therapy (CRT) by 2-[fluorine-18] fluoro-2-deoxy-D-glucose-labeled positron emission tomography/computed tomography ([18 FDG] PET/CT) imaging and correlate with response to CRT. Methods and Materials: Patients with cT2-4N0-2M0 distal rectal adenocarcinoma treated with long-course neoadjuvant CRT (54 Gy, 5-fluouracil-based) were prospectively studied (ClinicalTrials. org identifier NCT00254683). All patients underwent 3 PET/CT studies (at baseline and 6 and 12 weeks fromCRT completion). Clinical assessment was at 12 weeks. Maximal standard uptakevalue (SUVmax) of the primary tumor wasmeasured and recorded at eachPET/CTstudy after 1 h (early) and3 h (late) from 18 FDGinjection. Patientswith an increase in early SUVmax between 6 and 12 weeks were considered " bad" responders and the others as "good" responders. Results: Ninety-one patients were included; 46 patients (51%) were "bad" responders, whereas 45 (49%) patients were " good" responders. " Bad" responders were less likely to develop complete clinical response (6.5% vs. 37.8%, respectively; PZ. 001), less likely to develop significant histological tumor regression (complete or near-complete pathological response; 16% vs. 45%, respectively; PZ. 008) and exhibited greater final tumor dimension (4.3cmvs. 3.3cm; PZ. 03). Decrease between early (1 h) and late (3 h) SUVmax at 6-week PET/CTwas a significant predictor of " good" response (accuracy of 67%). Conclusions: Patients who developed an increase in SUVmax after 6 weeks were less likely to develop significant tumor downstaging. Early-late SUVmax variation at 6-week PET/CT may help identify these patients and allow tailored selection of CRT-surgery intervals for individual patients. (C) 2012 Elsevier Inc.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To evaluate the dosimetric characteristics of a new formulation of MAGIC gel, called MAGIC-f, which contains the addition of 3.3% formaldehyde, resulting in a gel with increased thermal stability. Methods: MAGIC-f gel was prepared and stored in hermetically sealed plastic containers. After irradiation, magnetic resonance images (MRI) were acquired to evaluate dose and dose distribution. Dosimetric characterization was performed by means of depth dose measurements, dose response sensitivity and linearity, temporal stability, energy and dose rate dependence, dose integration using sequential beams, temperature influence during MRI acquisition and dose distribution integrity. Results: MAGIC-f depth dose measurements are compatible with the dosimetric table data within +/- 4% uncertainty. The dosimeter's R-2 response varies linearly with dose at least from 0 to 6 Gy. The time-course of the sensitivity of the dosimeter following irradiation, indicated stabilization after 2 weeks. The dosimeter's response to irradiation was altered by 6% when increasing the energy from cobalt beams to 10 MV beams. The dose rate dependence of this new formulation of gel dosimeter is small: less than 2.5% for a variation from 200 to 500 cGy/min, and the dependence with the fractionation scheme is about 50% smaller than for standard MAGIC gel, The dependence on scanning temperature was also verified, and the integrity of the dose distribution was confirmed for a period of 90 days. Conclusions: The results demonstrate the applicability of this new dosimeter in tridimensional dose distribution measurements. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Semi-quantitative stenosis assessment by coronary CT angiography only modestly predicts stress-induced myocardial perfusion abnormalities. The performance of quantitative CT angiography (QCTA) for identifying patients with myocardial perfusion defects remains unclear. CorE-64 is a multicenter, international study to assess the accuracy of 64-slice QCTA for detecting a parts per thousand yen50% coronary arterial stenoses by quantitative coronary angiography (QCA). Patients referred for cardiac catheterization with suspected or known coronary artery disease were enrolled. Area under the receiver-operating-characteristic curve (AUC) was used to evaluate the diagnostic accuracy of the most severe coronary artery stenosis in a subset of 63 patients assessed by QCTA and QCA for detecting myocardial perfusion abnormalities on exercise or pharmacologic stress SPECT. Diagnostic accuracy of QCTA for identifying patients with myocardial perfusion abnormalities by SPECT revealed an AUC of 0.71, compared to 0.72 by QCA (P = .75). AUC did not improve after excluding studies with fixed myocardial perfusion abnormalities and total coronary arterial occlusions. Optimal stenosis threshold for QCTA was 43% yielding a sensitivity of 0.81 and specificity of 0.50, respectively, compared to 0.75 and 0.69 by QCA at a threshold of 59%. Sensitivity and specificity of QCTA to identify patients with both obstructive lesions and myocardial perfusion defects were 0.94 and 0.77, respectively. Coronary artery stenosis assessment by QCTA or QCA only modestly predicts the presence and the absence of myocardial perfusion abnormalities by SPECT. Confounding variables affecting the relationship between coronary anatomy and myocardial perfusion likely account for some of the observed discrepancies between coronary angiography and SPECT results.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective. To standardize the design of individually fitted implants based on computed tomographic (CT) images for use in medialization laryngoplasty without intraoperative voice monitoring. Study Design. Prospective tomographic and anatomical experimental study of 10 human cadaveric larynges. Methods. CT scans of 10 excised human larynges were analyzed to define the shape and size of ideal implants for medialization laryngoplasty. Silicone implants were designed according to CT parameters and used in simulated laryngoplasties in the laryngeal specimens. The efficacy of each implant in providing adequate medialization of the vocal fold was evaluated. Results. Diverse shapes and sizes of implants were obtained, reflecting variations in laryngeal anatomy. The implants enabled regular medialization of the entire extent of the free border of the vocal fold, including its posterior aspect. Medialization was considered adequate in all cases. Conclusions. This method proved to be a simple and efficient way to design individualized implants for medialization laryngoplasty, regardless of the size and shape of the larynx.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: Pulmonary fissures completeness predicts efficacy in endobronchial valves (EBV) implantation, a new lobar volume reduction therapy for severe emphysematous patients. We assessed the incidence of incomplete fissures and the interobserver agreement in its evaluation with MDCT, in severe emphysematous patients prior to EBV implantation. Materials and Methods: Volumetric thin-section CT scans of 35 patients (CODP GOLD 3/4, heterogeneous emphysema) were retrospectively reviewed by 2 pneumologists, 1 general and 2 experienced chest radiologists, independently and blinded for treatment outcome, and the pulmonary fissures were classified as either complete or incomplete. Interobserver agreement was assessed with Kappa index (KI). Results: Agreement between all readers for the left oblique, right oblique and horizontal fissure was, respectively, moderate (KI = 0.53), fair (KI = 0.37) and moderate (KI = 0.42). Highest agreement (99/105 fissures) was observed among experienced radiologists, being for left oblique, right oblique and horizontal, respectively, almost perfect (KI = 0.79), perfect (KI = 1.0) and moderate (KI = 0.52). These 2 reviewers found that all of 35 patients had at least one incomplete fissure, with a proportion of incomplete fissures assigned as 74/65%, 85/85% and 91/88%, respectively for the left oblique, right oblique and horizontal fissures. Conclusions: Pneumologists and radiologists agreed fairly to moderately in fissures analysis, while the experienced chest radiologists reached the highest clinically adequate agreement of 94%. We believe that clinical routine visual analysis of the fissures integrity can be done with a good degree of confidence in MDCT images, and experienced readers might be required. Also, a higher than expected incidence of incomplete fissures was described in our studied population. (C) 2012 Elsevier Ireland Ltd. All rights reserved.