25 resultados para spectrophotometry.


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Our aim was to investigate and determine the associations between oxidative stress (OS), dyslipidemia and inflammation in patients treated with continuous ambulatory peritoneal dialysis (CAPD) and hemodialysis (HD) using observational cross-sectional study. Twenty patients in CAPD and 48 in HD for at least 8 weeks and aged =18 years were included in the study. Individuals with malignant or acute inflammatory disease were excluded. A control group of 17 healthy individuals was also recruited. The biochemical parameter evaluations were analyzed using colorimetric kits for albumin, serum glucose, total cholesterol (TC) and lipid fractions. To determine the inflammatory status, CRP, IL-6 and TNF-a were analyzed by automated chemiluminescence kits. Plasma advanced oxidation protein products (AOPP) were determined by spectrophotometry. Mean AOPP levels were significantly higher for the HD group compared to the control, and there was no difference in AOPP concentrations between the control and CAPD groups. Dialysis patients had levels of inflammatory parameters higher than controls, and showed a high prevalence of patients with dyslipidemia, especially in CAPD. In the HD group, AOPP was positively correlated with triglycerides (TG) and inversely associated with HDL. Also the HD group was observed to have negative associations between TNF-a and HDL, LDL and TC. In the CAPD group, CRP was inversely correlated with HDL. Hemodialysis patients had increased protein OS and associations of inflammation and dyslipidemia were also observed in these dialysis groups. A more detailed characterization of the relations between oxidative stress and other more traditional risk factors has therapeutic importance, since cardiovascular diseases are the leading cause of death among dialysis patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work, a LED (light emitting diode) based photometer for solid phase photometry is described. The photometer was designed to permit direct coupling of a light source (LED) and a photodiode to a flow cell with an optical pathlength of 4 mm. The flow cell was filled with adsorbing solid phase material (C-18), which was used to immobilize the chromogenic reagent 1-(2-thiazolylazo)-2-naphthol (TAN). Aiming to allow accuracy assessment, samples were also analyzed employing ICP OES (inductively coupled plasma optical emission spectrometry) methodology. Applying the paired t-test at the 95% confidence level, no significant difference was observed. Other useful features were also achieved: linear response ranging from 0.05 to 0.85 mg L-1 Zn, limit of detection of 9 mu g L-1 Zn (3 sigma criterion), standard deviation of 1.4% (n = 10), sampling throughput of 36 determinations per h, and a waste generation and reagent consumption of 1.7 mL and of 0.03 mu g per determination, respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cloud point extraction (CPE) was employed for separation and preconcentration prior to the determination of nickel by graphite furnace atomic absorption spectrometry (GFAAS), flame atomic absorption spectrometry (FAAS) or UV-Vis spectrophotometry. Di-2-pyridyl ketone salicyloylhydrazone (DPKSH) was used for the first time as a complexing agent in CPE. The nickel complex was extracted from the aqueous phase using the Triton X-114 surfactant. Under optimized conditions, limits of detection obtained with GFAAS, FAAS and UV-Vis spectrophotometry were 0.14, 0.76 and 1.5 mu g L-1, respectively. The extraction was quantitative and the enrichment factor was estimated to be 27. The method was applied to natural waters, hemodialysis concentrates, urine and honey samples. Accuracy was evaluated by analysis of the NIST 1643e Water standard reference material.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: The aim of this study was to assess the nutritional zinc (Zn) status of elite swimmers during different training periods. Methods: A longitudinal paired study was performed at the University of Sao Paulo in eight male swimmers 18 to 25 y old who had been swimming competitively at the state and national levels for at least 5 y. The swimmers were evaluated over a total period of 14 wk: before the basic and specific preparatory period (BSPP-baseline), at the end of the basic and specific preparatory period (post-BSPP), and at the end of the polishing period (PP). Levels of Zn were determined in the plasma, erythrocyte, urine, and saliva by atomic absorption spectrophotometry. Anthropometric measurements and a 3-d food record were also evaluated. Results: The median plasma Zn concentration was below the reference value in all training periods (BSPP-baseline 59 mu g/dL, post-BSPP 55.9 mu g/dL, after PP 58.8 mu g/dL, P > 0.05), as were threshold values for erythrocytes (BSPP-baseline 36.5 mu g of Zn/g of hemoglobin, post-BSPP 42 mu g of Zn/g of hemoglobin, after PP 40.7 mu g of Zn/g of hemoglobin, P > 0.05), urinary Zn (BSPP-baseline 280 mu g/24 h, post-BSPP 337 mu g/24 h, after PP 284 mu g/24 h, P > 0.05), and salivary Zn (BSPP-baseline 66.1 mu g/L, post-BSPP 54.1 mu g/L, after PP 79.7 mu g/L, > 0.05). Salivary Zn did not correlate with plasma and erythrocyte Zn levels. Conclusion: The results suggest that the elite swimmers studied presented a possible Zn deficiency and that salivary Zn was not adequate to evaluate the Zn nutritional status. (C) 2012 Elsevier Inc. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nowadays, the attainment of microsystems that integrate most of the stages involved in an analytical process has raised an enormous interest in several research fields. This approach provides experimental set-ups of increased robustness and reliability, which simplify their application to in-line and continuous biomedical and environmental monitoring. In this work, a novel, compact and autonomous microanalyzer aimed at multiwavelength colorimetric determinations is presented. It integrates the microfluidics (a three-dimensional mixer and a 25 mm length "Z-shape" optical flow-cell), a highly versatile multiwavelength optical detection system and the associated electronics for signal processing and drive, all in the same device. The flexibility provided by its design allows the microanalyzer to be operated either in single fixed mode to provide a dedicated photometer or in multiple wavelength mode to obtain discrete pseudospectra. To increase its reliability, automate its operation and allow it to work under unattended conditions, a multicommutation sub-system was developed and integrated with the experimental set-up. The device was initially evaluated in the absence of chemical reactions using four acidochromic dyes and later applied to determine some key environmental parameters such as phenol index, chromium(VI) and nitrite ions. Results were comparable with those obtained with commercial instrumentation and allowed to demonstrate the versatility of the proposed microanalyzer as an autonomous and portable device able to be applied to other analytical methodologies based on colorimetric determinations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Modifications in low-density lipoprotein (LDL) have emerged as a major pathogenic factor of atherosclerosis, which is the main cause of morbidity and mortality in the western world. Measurements of the heat diffusivity of human LDL solutions in their native and in vitro oxidized states are presented by using the Z-Scan (ZS) technique. Other complementary techniques were used to obtain the physical parameters necessary to interpret the optical results, e. g., pycnometry, refractometry, calorimetry, and spectrophotometry, and to understand the oxidation phase of LDL particles. To determine the sample's thermal diffusivity using the thermal lens model, an iterative one-parameter fitting method is proposed which takes into account several characteristic ZS time-dependent and the position-dependent transmittance measurements. Results show that the thermal diffusivity increases as a function of the LDL oxidation degree, which can be explained by the increase of the hydroperoxides production due to the oxidation process. The oxidation products go from one LDL to another, disseminating the oxidation process and caring the heat across the sample. This phenomenon leads to a quick thermal homogenization of the sample, avoiding the formation of the thermal lens in highly oxidized LDL solutions. (C) 2012 Society of Photo-Optical Instrumentation Engineers (SPIE). [DOI: 10.1117/1.JBO.17.10.105003]

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A derivative spectrophotometric method was validated for quantification of acyclovir in poly (n-butylcyanoacrylate) (PBCA) nanoparticles. Specificity, linearity, precision, accuracy, recovery, detection (LOD) and quantification (LOQ) limits were established for method validation. First-derivative at 295.2 nm eliminated interferences from nanoparticle ingredients and presented linearity for acyclovir concentrations ranging from 1.25 to 40.0 µg/mL (r = 0.9999). Precision and accuracy data demonstrated good reproducibility. Recovery ranged from 99.3 to 101.2. LOD was 0.08 µg/mL and LOQ, 0.25 µg/mL. Thus, the proposed method proved to be easy, low cost, and accurate, and therefore, an useful alternative to quantify acyclovir in nanoparticles.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Neste trabalho é proposto um fotômetro baseado em LED (diodo emissor de luz) para fotometria em fase sólida. O fotômetro foi desenvolvido para permitir o acoplamento da fonte de radiação (LED) e do fotodetector direto na cela de fluxo, tendo um caminho óptico de 4 mm. A cela de fluxo foi preenchida com material sólido (C18), o qual foi utilizado para imobilizar o reagente cromogênico 1-(2-tiazolilazo)-2-naftol (TAN). A exatidão foi avaliada empregando dados obtidos através da técnica ICP OES (espectrometria de emissão por plasma indutivamente acoplado). Aplicando-se o teste-t pareado não foi observada diferença significativa em nível de confiança de 95%. Outros parâmetros importantes encontrados foram faixa de resposta linear de 0,05 a 0,85 mg L-1 Zn, limite de detecção de 9 µg L-1 Zn (n = 3), desvio padrão de 1,4 % (n = 10), frequência de amostragem de 36 determinações por h, e uma geração de efluente e consumo de reagente de 1,7 mL e 0,03 µg por determinação, respectivamente.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The effect of different propionaldehyde ratios on the properties of bis-GMA-based comonomers and copolymers diluted with propoxylated bis-GMA (CH3bis-GMA) was evaluated. Five experimental comonomers were prepared combining bis-GMA with CH3bis-GMA and propionaldehyde at 0, 2, 8, 16, 24 mol%. Light polymerization was effected with the use of 0.2 wt. (%) each of camphorquinone and N,N-dimethyl-p-toluidine. Resin degrees of conversion (%DC) were evaluated by FT-IR spectrophotometry and Tg by Differential Scanning Calorimeter. Complex viscosity (η*), the effect of temperature on η*, and Microhardness (H) for dry and wet samples were also determined. Data were analyzed by Student's t-test, one-way ANOVA and Tukey-Kramer test (α = 0.05). The group with 24 mol% additive had a significant increase in %DC and H, and the lowest comonomer Tg and η*. No remarkable variation was noted in copolymers Tg s. All resins presented Newtonian behavior of viscosity, which linearly decreased with increased temperature. The η* decreased sigmoidally as the additive ratio increased.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The viability and interpretation of techniques for the evaluation of immunocompetence of animals in their natural environment has been largely debated. One of these methods is based on testing the antimicrobial capacity of the blood and/or plasma in vitro, which could rapidly and effectively assess the immunological conditions of natural populations. We tested the applicability of the antimicrobial capacity of plasma (ACP) assay in anuran amphibians from the Atlantic Forest. The assay was performed by measuring both the turbidity (in a spectrophotometer) and the colony forming units (CFU) of the remaining bacteria (Escherichia coli) following exposure to amphibian plasma. Although both assays were correlated, the ACP assay by spectrophotometry showed 10 times lower intra-assay variation. We also found interspecific variation in ACP, as well as the maintenance of ACP values in males from the same population, collected in different breeding seasons. Thus, the estimation of ACP by spectrophotometry provides a convenient and accurate method for evaluating innate immunocompetence in comparative and ecophysiological studies of anuran amphibians.