38 resultados para micro-CT,cone beam Ct,trabecular tissue,image segmentation,computed tomography


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: This study examined the anatomy of 4-rooted maxillary second molars by using micro computed tomography. Methods: Twenty-five 4-rooted maxillary second molars were scanned to evaluate the size and curvature of the roots; the distance and spatial configuration between some anatomical landmarks; the number of root canals and the position of apical foramina; the occurrence of fusion of roots and enamel pearls; the configuration of the canal at the apical third; the cross-sectional appearance, the volume, and surface area of the root canals. Data were compared by using analysis of variance post hoc Tukey test (alpha = 0.05). Results: The specimens were classified as types I (n = 16), II (n = 7), and III (n = 2). The size of the roots was similar (P > .05), and most of them presented straight with 1 canal, except the mesiobuccal that showed 2 canals in 24% of the samples. The configuration of the pulp chamber was mostly irregular quadrilateral-shaped. The lowest mean distance of the orifices was observed between the buccal roots (P < .05). Accessory canals were present mostly in the apical third. Location of the apical foramina varied considerably. Fusion of roots and enamel pearls occurred in 44% and 8% of the samples, respectively. Mean distance from the pulp chamber floor to the furcation was 2.15 +/- 0.57 mm. No statistical differences were found in the bi-dimensional and 3-dimensional analyses (P > .05). Conclusions: All analyzed parameters showed differences between roots, except for the length of the roots, the configuration of the canals at the apical third, cross-sectional appearance, volume, and surface area of the canals. (J Endod 2012;38:977-982)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate tools for the fusion of images generated by tomography and structural and functional magnetic resonance imaging. METHODS: Magnetic resonance and functional magnetic resonance imaging were performed while a volunteer who had previously undergone cranial tomography performed motor and somatosensory tasks in a 3-Tesla scanner. Image data were analyzed with different programs, and the results were compared. RESULTS: We constructed a flow chart of computational processes that allowed measurement of the spatial congruence between the methods. There was no single computational tool that contained the entire set of functions necessary to achieve the goal. CONCLUSION: The fusion of the images from the three methods proved to be feasible with the use of four free-access software programs (OsiriX, Register, MRIcro and FSL). Our results may serve as a basis for building software that will be useful as a virtual tool prior to neurosurgery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Few data on the definition of simple robust parameters to predict image noise in cardiac computed tomography (CT) exist. Objectives: To evaluate the value of a simple measure of subcutaneous tissue as a predictor of image noise in cardiac CT. Methods: 86 patients underwent prospective ECG-gated coronary computed tomographic angiography (CTA) and coronary calcium scoring (CAC) with 120 kV and 150 mA. The image quality was objectively measured by the image noise in the aorta in the cardiac CTA, and low noise was defined as noise < 30HU. The chest anteroposterior diameter and lateral width, the image noise in the aorta and the skin-sternum (SS) thickness were measured as predictors of cardiac CTA noise. The association of the predictors and image noise was performed by using Pearson correlation. Results: The mean radiation dose was 3.5 ± 1.5 mSv. The mean image noise in CT was 36.3 ± 8.5 HU, and the mean image noise in non-contrast scan was 17.7 ± 4.4 HU. All predictors were independently associated with cardiac CTA noise. The best predictors were SS thickness, with a correlation of 0.70 (p < 0.001), and noise in the non-contrast images, with a correlation of 0.73 (p < 0.001). When evaluating the ability to predict low image noise, the areas under the ROC curve for the non-contrast noise and for the SS thickness were 0.837 and 0.864, respectively. Conclusion: Both SS thickness and CAC noise are simple accurate predictors of cardiac CTA image noise. Those parameters can be incorporated in standard CT protocols to adequately adjust radiation exposure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: The objective of this study is to compare subjective image quality and diagnostic validity of cone-beam CT (CBCT) panoramic reformatting with digital panoramic radiographs. Materials and methods: Four dry human skulls and two formalin-fixed human heads were scanned using nine different CBCTs, one multi-slice CT (MSCT) and one standard digital panoramic device. Panoramic views were generated from CBCTs in four slice thicknesses. Seven observers scored image quality and visibility of 14 anatomical structures. Four observers repeated the observation after 4 weeks. Results: Digital panoramic radiographs showed significantly better visualization of anatomical structures except for the condyle. Statistical analysis of image quality showed that the 3D imaging modalities (CBCTs and MSCT) were 7.3 times more likely to receive poor scores than the 2D modality. Yet, image quality from NewTom VGi® and 3D Accuitomo 170® was almost equivalent to that of digital panoramic radiographs with respective odds ratio estimates of 1.2 and 1.6 at 95% Wald confidence limits. A substantial overall agreement amongst observers was found. Intra-observer agreement was moderate to substantial. Conclusions: While 2D-panoramic images are significantly better for subjective diagnosis, 2/3 of the 3D-reformatted panoramic images are moderate or good for diagnostic purposes. Clinical relevance: Panoramic reformattings from particular CBCTs are comparable to digital panoramic images concerning the overall image quality and visualization of anatomical structures. This clinically implies that a 3D-derived panoramic view can be generated for diagnosis with a recommended 20-mm slice thickness, if CBCT data is a priori available for other purposes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to determine whether image artifacts caused by orthodontic metal accessories interfere with the accuracy of 3D CBCT model superimposition. A human dry skull was subjected three times to a CBCT scan: at first without orthodontic brackets (T1), then with stainless steel brackets bonded without (T2) and with orthodontic arch wires (T3) inserted into the brackets' slots. The registration of image surfaces and the superimposition of 3D models were performed. Within-subject surface distances between T1-T2, T1-T3 and T2-T3 were computed and calculated for comparison among the three data sets. The minimum and maximum Hausdorff Distance units (HDu) computed between the corresponding data points of the T1 and T2 CBCT 3D surface images were 0.000000 and 0.049280 HDu, respectively, and the mean distance was 0.002497 HDu. The minimum and maximum Hausdorff Distances between T1 and T3 were 0.000000 and 0.047440 HDu, respectively, with a mean distance of 0.002585 HDu. In the comparison between T2 and T3, the minimum, maximum and mean Hausdorff Distances were 0.000000, 0.025616 and 0.000347 HDu, respectively. In the current study, the image artifacts caused by metal orthodontic accessories did not compromise the accuracy of the 3D model superimposition. Color-coded maps of overlaid structures complemented the computed Hausdorff Distances and demonstrated a precise fusion between the data sets.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Previous studies have reported increased cerebral blood flow (CBF) velocity after decompressive craniectomy in traumatic brain injury (TBI) patients. A 27-year-old man presented with clinical and tomographic signs of cerebral herniation secondary to TBI. Prior to decompressive craniectomy, hemodynamic study by perfusion computed tomography (CT) indicated diffuse cerebral hyperperfusion. Following surgical decompression, the patient recovered neurologically and perfusion CT disclosed a decrease in the intensity of cerebral perfusion. The patient's blood pressure levels were similar at both pre- and postoperative perfusion CT examinations. This finding provides indirect evidence that decompressive craniectomy may improve mechanisms of CBF regulation in TBI, providing pathophysiological insights in the cerebral hemodynamics of TBI patients. This is the first report analyzing the hemodynamic changes through perfusion CT (PCT) in a patient with decompressive craniotomy due to TBI. (C) 2012 Elsevier Masson SAS. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Several pancreatic diseases may require surgical treatment, with most of these procedures classified as resection or drainage. Resection procedures, which are usually performed to remove pancreatic tumors, include pancreatoduodenectomy, central pancreatectomy, distal pancreatectomy, and total pancreatectomy. Drainage procedures are usually performed to treat chronic pancreatitis after the failure of medical therapy and include the Puestow and Frey procedures. The type of surgery depends not only on the patient's symptoms and the location of the disease, but also on the expertise of the surgeon. Radiologists should become familiar with these surgical procedures to better understand postoperative changes in anatomic findings. Multidetector computed tomography is the modality of choice for identifying normal findings after surgery, postoperative complications, and tumor recurrence in patients who have undergone pancreatic surgery. (C)RSNA, 2012 . radiographics.rsna.org

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Semi-quantitative stenosis assessment by coronary CT angiography only modestly predicts stress-induced myocardial perfusion abnormalities. The performance of quantitative CT angiography (QCTA) for identifying patients with myocardial perfusion defects remains unclear. CorE-64 is a multicenter, international study to assess the accuracy of 64-slice QCTA for detecting a parts per thousand yen50% coronary arterial stenoses by quantitative coronary angiography (QCA). Patients referred for cardiac catheterization with suspected or known coronary artery disease were enrolled. Area under the receiver-operating-characteristic curve (AUC) was used to evaluate the diagnostic accuracy of the most severe coronary artery stenosis in a subset of 63 patients assessed by QCTA and QCA for detecting myocardial perfusion abnormalities on exercise or pharmacologic stress SPECT. Diagnostic accuracy of QCTA for identifying patients with myocardial perfusion abnormalities by SPECT revealed an AUC of 0.71, compared to 0.72 by QCA (P = .75). AUC did not improve after excluding studies with fixed myocardial perfusion abnormalities and total coronary arterial occlusions. Optimal stenosis threshold for QCTA was 43% yielding a sensitivity of 0.81 and specificity of 0.50, respectively, compared to 0.75 and 0.69 by QCA at a threshold of 59%. Sensitivity and specificity of QCTA to identify patients with both obstructive lesions and myocardial perfusion defects were 0.94 and 0.77, respectively. Coronary artery stenosis assessment by QCTA or QCA only modestly predicts the presence and the absence of myocardial perfusion abnormalities by SPECT. Confounding variables affecting the relationship between coronary anatomy and myocardial perfusion likely account for some of the observed discrepancies between coronary angiography and SPECT results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: A wide variety of manifestations is presented in patients with Gaucher's disease (GD), including bone, haematology and visceral disturbances. This study was conducted to ascertain the main maxillofacial abnormalities by means of clinical survey, panoramic and cone beam CT (CBCT); to compare the patient's group with an age-sex matched control group; and to correlate clinical and radiological data. Methods: Ten patients previously diagnosed with GD were submitted to clinical and radiological surveys (CBCT and panoramic radiographs). The examination consisted of anamnesis, extra- and intraoral examinations and analyses of each patient's records. Imaging data were collected from the point of view of 3 observers, and the results compared with a healthy group (20 individuals) by means of statistical analysis (Fisher's exact test). Results: Gaucher patients had significantly more manifestations than otherwise healthy carriers. The most prevalent findings were enlarged marrow spaces, generalized osteopenia and effacement of jaw structures (mandibular canal, lamina dura and mental foramen). Here we describe a case in which thickening of the maxillary sinus mucosa was observed on CBCT rather than opacification of the sinus as seen on panoramic radiographs. Pathological fractures, root resorption and delay on tooth eruption were not observed. Conclusions: A poor relationship could be observed between clinical and radiological data. Patients showed important bone manifestations, which require careful diagnostic and surgical planning whenever necessary. Although panoramic radiographs have shown significant differences, CBCT is more effective in pointing out differences between patients and a control group, thus showing it as an important tool for evaluation of Gaucher patients. Dentomaxillofacial Radiology (2012) 41, 541-547. doi: 10.1259/dmfr/143023353

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: DON, a serious complication of GO, is frequently difficult to diagnose clinically in its early stages because of confounding signs and symptoms of congestive orbitopathy. We evaluated the ability of square area measurements of orbital apex crowding, calculated with MDCT, to detect DON. MATERIALS AND METHODS: Fifty-six patients with GO were studied prospectively with complete neuro-ophthalmologic examination and MDCT scanning. Square measurements were taken from coronal sections 12 mm, 18 mm, and 24 mm from the interzygomatic line. The ratio between the extraocular muscle area and the orbital bone area was used as a Cl. Intracranial fat prolapse through the superior orbital fissure was recorded as present or absent. Severity of optic nerve crowding was also subjectively graded on corona! images. Orbits were divided into 2 groups (with or without clinical evidence of DON) and compared. RESULTS: Ninety-five orbits (36 with and 59 without DON) were studied. The CIs at all 3 levels and the subjective crowding score were significantly greater in orbits with DON (P<.001). No significant difference was observed regarding intracranial fat prolapse (P=.105). The area under the ROC curves was 0.91, 0.93, and 0.87 for CIs at 12, 18, and 24 mm, respectively. The best performance was at 18 mm, where a cutoff value of 57.5% corresponded to 91.7% sensitivity, 89.8% specificity, and an odds ratio of 97.2 for detecting DON. A significant correlation (P<.001) between the CIs and VF defects was observed. CONCLUSIONS: Orbital Cls based on area measurements were found to predict DON more reliably than subjective grading of orbital crowding or intracranial fat prolapse.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Facial reconstruction is a method that seeks to recreate a person's facial appearance from his/her skull. This technique can be the last resource used in a forensic investigation, when identification techniques such as DNA analysis, dental records, fingerprints and radiographic comparison cannot be used to identify a body or skeletal remains. To perform facial reconstruction, the data of facial soft tissue thickness are necessary. Scientific literature has described differences in the thickness of facial soft tissue between ethnic groups. There are different databases of soft tissue thickness published in the scientific literature. There are no literature records of facial reconstruction works carried out with data of soft tissues obtained from samples of Brazilian subjects. There are also no reports of digital forensic facial reconstruction performed in Brazil. There are two databases of soft tissue thickness published for the Brazilian population: one obtained from measurements performed in fresh cadavers (fresh cadavers' pattern), and another from measurements using magnetic resonance imaging (Magnetic Resonance pattern). This study aims to perform three different characterized digital forensic facial reconstructions (with hair, eyelashes and eyebrows) of a Brazilian subject (based on an international pattern and two Brazilian patterns for soft facial tissue thickness), and evaluate the digital forensic facial reconstructions comparing them to photos of the individual and other nine subjects. The DICOM data of the Computed Tomography (CT) donated by a volunteer were converted into stereolitography (STL) files and used for the creation of the digital facial reconstructions. Once the three reconstructions were performed, they were compared to photographs of the subject who had the face reconstructed and nine other subjects. Thirty examiners participated in this recognition process. The target subject was recognized by 26.67% of the examiners in the reconstruction performed with the Brazilian Magnetic Resonance Pattern, 23.33% in the reconstruction performed with the Brazilian Fresh Cadavers Pattern and 20.00% in the reconstruction performed with the International Pattern, in which the target-subject was the most recognized subject in the first two patterns. The rate of correct recognitions of the target subject indicate that the digital forensic facial reconstruction, conducted with parameters used in this study, may be a useful tool. (C) 2011 Elsevier Ireland Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: Previous evidence supports a direct relationship between the calcium burden (volume) on post-contrast CT with the percent internal carotid artery (ICA) stenosis at the carotid bifurcation. We sought to further investigate this relationship by comparing non-enhanced CT (NECT) and digital subtraction angiography (DSA). Methods: 50 patients (aged 41-82 years) were retrospectively identified who had undergone cervical NECT and DSA. A 64-multidetector array CT (MDCT) scanner was utilised and the images reviewed using preset window widths/levels (30/300) optimised to calcium, with the volumes measured via three-dimensional reconstructive software. Stenosis measurements were performed on DSA and luminal diameter stenoses >40% were considered "significant". Volume thresholds of 0.01, 0.03, 0.06, 0.09 and 0.12 cm(3) were utilised and Pearson's correlation coefficient (r) was calculated to correlate the calcium volume with percent stenosis. Results: Of 100 carotid bifurcations, 88 were available and of these 7 were significantly stenotic. The NECT calcium volume moderately correlated with percent stenosis on DSA r=0.53 (p<0.01). A moderate-strong correlation was found between the square root of calcium volume on NECT with percent stenosis on DSA (r=0.60, p<0.01). Via a receiver operating characteristic curve, 0.06 cm(3) was determined to be the best threshold (sensitivity 100%, specificity 90.1%, negative predictive value 100% and positive predictive value 46.7%) for detecting significant stenoses. Conclusion: This preliminary investigation confirms a correlation between carotid bifurcation calcium volume and percent ICA stenosis and is promising for the optimal threshold for stenosis detection. Future studies could utilise calcium volumes to create a "score" that could predict high grade stenosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract: Bisphosphonate-related osteonecrosis of the jaws (BRONJ) is characterized as exposed bone in the jaws for more than 8 weeks in patients with current or previous history of therapy with bisphosphonates (BPs) and no history of radiotherapy in the head and neck. We report a case series of 7 patients with BRONJ and analyze the variations of clinical and imaging signs, correlating them with the presence or absence of bone exposure. Among the patients, 6 were women and 1 was a man, aged 42–79 years. Five of the patients were using zoledronic acid and the other 2 alendronate. The use of BPs varied from 3 to 13 years. In 5 patients, tooth extraction was the triggering event of injuries. Panoramic radiographs and computed tomography (CT) were evaluated by a radiologist blinded to the cases. There were persistent unremodeled extraction socket even several months after tooth extraction in 3 of the cases that were consistent wit CT findings that also showed areas of osteosclerosis and osteolysis. Patients were treated according to the recommendations of the AAOMS, with surgical debridement and antibiotic coverage with amoxicillin in the symptomatic patients. The follow-up of these patients ranged from 8 to 34 months, with a good response to treatment. The image findings in this case series were not specific and showed no difference between each stages of BRONJ (AAOMS, 2009). The image features were similar in presence or absence of exposed bone.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: This study aimed to assess the presence of additional foramina and canals in the anterior palate region, through cone beam computed tomography (CBCT) images, describing their location, direction, and diameter. Materials & Methods: CBCT exams of 178 subjects displaying the anterior maxilla were included and the following parameters were registered: gender; age group; presence of additional foramina in the anterior palate (AFP) with at least 1 mm in diameter; location and diameter of AFP; and direction of bony canals associated with AFP. Results: Twenty-eight patients (15.7%) presented AFP and in total 34 additional foramina were registered. No statistical differences between patients with or without AFP were found for gender or age. The average diameter of AFP was 1.4 mm (range from 1 to 1.9 mm). Their location was variable, with most of the cases occurring in the alveolar process near the incisors or canines (n = 27). In 18 cases, AFP was associated with bony canals with upward or oblique direction toward the anterior nasal cavity floor. In 14 cases, the canal presented as a direct extension of the canalis sinuosus, in an upward direction laterally to the nasal cavity aperture. In two cases, the canal was observed adjacent to the incisive and joined the nasopalatine canal superiorly. Discussion: CBCT images have a crucial role in the recognition of anatomical variations by allowing detailed tridimensional evaluations. Additional foramina and canals in the anterior region of the upper jaw are relatively frequent. Practitioners should be aware and trained to identify these variations. Conclusions: Over 15% of the population studied had additional foramina in the anterior palate, between 1 mm and 1.9 mm wide, with variable locations. In most cases the canals associated with these foramina either presented as a direct extension of the canalis sinuosus, or coursed towards the nasal cavity floor.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Computed tomography (CT)-guided percutaneous drilling is an alternative for osteoid osteoma treatment. This study aims to evaluate the remodeling of the drill orifice. The success rate and complications were also recorded and compared with other treatment methods.