23 resultados para eletrocardiografia computadorizada
Resumo:
Nowadays, image analysis is one of the most modern tools in evaluating physiological potential of seeds. This study aimed at verifying the efficiency of the seedling imaging analysis to assess physiological potential of wheat seeds. The seeds of wheat, cultivars IAC 370 and IAC 380, each of which represented by five different lots, were stored during four months under natural environmental conditions of temperature (T) and relative humidity (RH), in municipality of Piracicaba, Stated of São Paulo, Brazil. For this, bimonthly assessments were performed to quantify moisture content and physiological potential of seeds by means of tests of: germination, first count, accelerated aging, electrical conductivity, seedling emergence, and computerized analysis of seedlings, using the Seed Vigor Imaging System (SVIS®). It has been concluded that the computerized analyses of seedling through growth indexes and vigor, using the SVIS®, is efficient to assess physiological potential of wheat seeds.
Resumo:
O vigor da semente tem sido avaliado por meio de testes fisiológicos, bioquímicos e de tolerância a estresse. Mais recentemente, com o uso da análise computadorizada de imagens de plântulas, podem ser obtidas informações objetivas, em período relativamente curto, com menor interferência humana. O objetivo nesta pesquisa foi identificar testes eficientes para avaliação do vigor de sementes de alface, com ênfase para a análise de imagens digitais de plântulas. Sementes de 12 lotes (seis da cultivar Vanda e seis da Vera) foram avaliadas por meio de testes de germinação, germinação a baixa temperatura (15ºC), emergência de plântulas e envelhecimento acelerado tradicional e com solução salina (NaCl 40%) saturada, a 41ºC/48 h e 41ºC/72 h. Utilizou-se, também, o sistema de análise computadorizada de imagens de plântulas (SVIS®), desenvolvido pela Ohio State University (EUA), que forneceu dados referentes ao índice de vigor, uniformidade e crescimento de plântulas. Os testes foram realizados a cada três meses, durante 12 meses de armazenamento, sob condições ambiente. Com base nos resultados obtidos, concluiu-se que os testes de envelhecimento acelerado com uso de solução saturada de NaCl, a 41ºC por 48 e 72 horas e de velocidade de germinação, e os parâmetros obtidos com o software SVIS, índice de crescimento de plântulas e comprimento da raiz primária, são eficientes na avaliação do vigor de lotes de sementes de alface.
Resumo:
OBJETIVO: Estudo anatômico do áxis através de tomografia computadorizada (TC) em crianças de dois a dez anos de idade, mensurando a angulação das lâminas, espessura e comprimento de lâminas e pedículos e espessura da massa lateral. MÉTODOS: Estudou-se 64 TCs da coluna cervical de indivíduos com idades entre 24 e 120 meses, de ambos os sexos e sem deformidades cervicais. Correlacionaram-se as variáveis estudadas com os grupos etários e sexo dos pacientes. A análise estatística foi realizada por meio do teste t. RESULTADOS: Verificou-se que na faixa etária entre 24-48 meses, 5,5% das lâminas e 8,3% dos pedículos possuem espessura menores do que 3,5mm, espessura necessária para colocação de um parafuso. Entre 49-120 meses não há lâminas com espessuras menores do que 3,5mm e 1,2% dos pedículos possuem espessura menor do que 3,5mm. Em ambos os grupos etários não há comprimento de lâminas e pedículos menores do que 12 mm e massas laterais maiores do que 12 mm. CONCLUSÃO: A análise das dimensões obtidas no estudo permite, na maioria dos casos, a colocação de parafusos de 3,5mm nas lâminas e pedículos do áxis de crianças. Nível de Evidência II, Desenvolvimento de critérios diagnósticos em pacientes consecutivos.
Resumo:
OBJECTIVE: To evaluate tools for the fusion of images generated by tomography and structural and functional magnetic resonance imaging. METHODS: Magnetic resonance and functional magnetic resonance imaging were performed while a volunteer who had previously undergone cranial tomography performed motor and somatosensory tasks in a 3-Tesla scanner. Image data were analyzed with different programs, and the results were compared. RESULTS: We constructed a flow chart of computational processes that allowed measurement of the spatial congruence between the methods. There was no single computational tool that contained the entire set of functions necessary to achieve the goal. CONCLUSION: The fusion of the images from the three methods proved to be feasible with the use of four free-access software programs (OsiriX, Register, MRIcro and FSL). Our results may serve as a basis for building software that will be useful as a virtual tool prior to neurosurgery.
Resumo:
OBJECTIVE: To propose an automatic brain tumor segmentation system. METHODS: The system used texture characteristics as its main source of information for segmentation. RESULTS: The mean correct match was 94% of correspondence between the segmented areas and ground truth. CONCLUSION: Final results showed that the proposed system was able to find and delimit tumor areas without requiring any user interaction.
Resumo:
O tumor odontogênico cístico calcificante normalmente se manifesta como uma massa indolor, de crescimento lento, que acomete tanto a maxila como a mandíbula, tendo predileção pelo segmento anterior (área dos incisivos e caninos). Geralmente, ocorre em adultos jovens, na terceira a quarta década de vida, sem preferência por gênero. Imagens de tomografia computadorizada revelaram características importantes não detectadas na radiografia panorâmica, tais como fenestração, calcificação e estruturas dentiformes. A característica microscópica típica dessa lesão é a presença de células epiteliais aberrantes anucleadas, em quantidades variáveis, denominadas "células fantasmas". Também se pode encontrar dentina displásica e, ocasionalmente, os cistos estão associados a tecido dentário duro, semelhante ao odontoma. O tratamento do tumor odontogênico cístico calcificante incluiu simples enucleação e curetagem. O objetivo deste trabalho foi mostrar duas manifestações diferentes do tumor odontogênico cístico calcificante, em que a tomografia computadorizada, associada às características clínicas, foi ferramenta importante para o diagnóstico, o planejamento cirúrgico e o acompanhamento dos pacientes.
Resumo:
Background: Few data on the definition of simple robust parameters to predict image noise in cardiac computed tomography (CT) exist. Objectives: To evaluate the value of a simple measure of subcutaneous tissue as a predictor of image noise in cardiac CT. Methods: 86 patients underwent prospective ECG-gated coronary computed tomographic angiography (CTA) and coronary calcium scoring (CAC) with 120 kV and 150 mA. The image quality was objectively measured by the image noise in the aorta in the cardiac CTA, and low noise was defined as noise < 30HU. The chest anteroposterior diameter and lateral width, the image noise in the aorta and the skin-sternum (SS) thickness were measured as predictors of cardiac CTA noise. The association of the predictors and image noise was performed by using Pearson correlation. Results: The mean radiation dose was 3.5 ± 1.5 mSv. The mean image noise in CT was 36.3 ± 8.5 HU, and the mean image noise in non-contrast scan was 17.7 ± 4.4 HU. All predictors were independently associated with cardiac CTA noise. The best predictors were SS thickness, with a correlation of 0.70 (p < 0.001), and noise in the non-contrast images, with a correlation of 0.73 (p < 0.001). When evaluating the ability to predict low image noise, the areas under the ROC curve for the non-contrast noise and for the SS thickness were 0.837 and 0.864, respectively. Conclusion: Both SS thickness and CAC noise are simple accurate predictors of cardiac CTA image noise. Those parameters can be incorporated in standard CT protocols to adequately adjust radiation exposure.
Resumo:
O documento IAEA/TRS 457 [1] define qualidades de radiação para calibração de detectores utilizados em mediações na área de radiologia diagnóstica. O documento define qualidades específicas para feixes primários (RQR), transmitidos (RQA), bem como outros específicos para mamografia e tomografia computadorizada. Estas qualidades devem ser estabelecidas de acordo com a norma IEC 61267. O presente trabalho descreve a validação dos filtros de qualidade de radiação RQR, previamente estabelecidos, a determinação de filtros com qualidade de radiação RQA e a determinação das curvas de atenuação para ambos os casos.