38 resultados para biomechanics


Relevância:

10.00% 10.00%

Publicador:

Resumo:

NSAIDs are widely prescribed and used over the years to treat tendon injuries despite its well-known long-term side effects. In the last years several animal and human trials have shown that low-level laser therapy (LLLT) presents modulatory effects on inflammatory markers, however the mechanisms involved are not fully understood. The aim of this study was to evaluate the short-term effects of LLLT or sodium diclofenac treatments on biochemical markers and biomechanical properties of inflamed Achilles tendons. Wistar rats Achilles tendons (n?=?6/group) were injected with saline (control) or collagenase at peritendinous area of Achilles tendons. After 1?h animals were treated with two different doses of LLLT (810?nm, 1 and 3?J) at the sites of the injections, or with intramuscular sodium diclofenac. Regarding biochemical analyses, LLLT significantly decreased (p?<?0.05) COX-2, TNF-a, MMP-3, MMP-9, and MMP-13 gene expression, as well as prostaglandin E2 (PGE2) production when compared to collagenase group. Interestingly, diclofenac treatment only decreased PGE2 levels. Biomechanical properties were preserved in the laser-treated groups when compared to collagenase and diclofenac groups. We conclude that LLLT was able to reduce tendon inflammation and to preserve tendon resistance and elasticity. (c) 2012 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 30:19451951, 2012

Relevância:

10.00% 10.00%

Publicador:

Resumo:

During orthodontic tooth movement (OTM), alveolar bone is resorbed by osteoclasts in compression sites (CS) and is deposited by osteoblasts in tension sites (TS). The aim of this study was to develop a standardized OTM protocol in mice and to investigate the expression of bone resorption and deposition markers in CS and TS. An orthodontic appliance was placed in C57BL6/J mice. To define the ideal orthodontic force, the molars of the mice were subjected to forces of 0.1 N, 0.25 N, 0.35 N and 0.5 N. The expression of mediators that are involved in bone remodeling at CS and TS was analyzed using a Real-Time PCR. The data revealed that a force of 0.35 N promoted optimal OTM and osteoclast recruitment without root resorption. The levels of TNF-alpha, RANKL, MMP13 and OPG were all altered in CS and TS. Whereas TNF-a and Cathepsin K exhibited elevated levels in CS. RUNX2 and OCN levels were higher in TS. Our results suggest that 0.35 N is the ideal force for OTM in mice and has no side effects. Moreover, the expression of bone remodeling markers differed between the compression and the tension areas, potentially explaining the distinct cellular migration and differentiation patterns in each of these sites. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Walking on irregular surfaces and in the presence of unexpected events is a challenging problem for bipedal machines. Up to date, their ability to cope with gait disturbances is far less successful than humans': Neither trajectory controlled robots, nor dynamic walking machines (Limit CycleWalkers) are able to handle them satisfactorily. On the contrary, humans reject gait perturbations naturally and efficiently relying on their sensory organs that, if needed, elicit a recovery action. A similar approach may be envisioned for bipedal robots and exoskeletons: An algorithm continuously observes the state of the walker and, if an unexpected event happens, triggers an adequate reaction. This paper presents a monitoring algorithm that provides immediate detection of any type of perturbation based solely on a phase representation of the normal walking of the robot. The proposed method was evaluated in a Limit Cycle Walker prototype that suffered push and trip perturbations at different moments of the gait cycle, providing 100% successful detections for the current experimental apparatus and adequately tuned parameters, with no false positives when the robot is walking unperturbed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O objetivo deste estudo foi analisar a reprodutibilidade de parâmetros no domínio da frequência do sinal eletromiográfico (EMG) utilizados na caracterização da fadiga muscular localizada. Quinze sujeitos do sexo masculino foram submetidos a um teste de fadiga baseado na extensão isométrica de joelho, sendo realizados em três momentos distintos com intervalos de sete dias. Para avaliar a reprodutibilidade dos dados entres os testes calculou-se o coeficiente de correlação intraclasse (CCI) para a frequência mediana (Fmed) no tempo total de exercício (FmedT), para a Fmed obtida a cada 10% do tempo de exercício (Fmed10%) e para as potências das bandas de frequência, obtidas da divisão do espectro de potência a cada 20 Hz. Os resultados demonstraram: (1) boa reprodutibilidade para a FmedT; (2) boa reprodutibilidade para a Fmed10%; e (3) maior variação no sinal EMG nas bandas de 20 a 120 Hz, no qual se destacam as bandas de 20-40 Hz e de 40-60 Hz, demonstrando maior sensibilidade ao processo de fadiga muscular. Conclui-se que a Fmed é uma variável que apresenta boa reprodutibilidade e que a análise fragmentada do espectro de potência, por meio das bandas de frequência, demonstrou-se sensível as variações que ocorrem no sinal EMG durante a instalação do processo de fadiga, tendo potencial para se tornar um novo método para a caracterização da fadiga muscular localizada.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Statement of problem. The retention of an Aramany Class IV removable partial dental prosthesis can be compromised by a lack of support. The biomechanics of this obturator prosthesis result in an unusual stress distribution on the residual maxillary bone. Purpose. This study evaluated the biomechanics of an Aramany Class IV obturator prosthesis with finite element analysis and a digital 3-dimensional (3-D) model developed from a computed tomography scan; bone stress was evaluated according to the load placed on the prosthesis. Material and methods. A 3-D model of an Aramany Class IV maxillary resection and prosthesis was constructed. This model was used to develop a finite element mesh. A 120 N load was applied to the occlusal and incisal platforms corresponding to the prosthetic teeth. Qualitative analysis was based on the scale of maximum principal stress; values obtained through quantitative analysis were expressed in MPa. Results. Under posterior load, tensile and compressive stresses were observed; the tensile stress was greater than the compressive stress, regardless of the bone region, and the greatest compressive stress was observed on the anterior palate near the midline. Under an anterior load, tensile stress was observed in all of the evaluated bone regions; the tensile stress was greater than the compressive stress, regardless of the bone region. Conclusions. The Aramany Class IV obturator prosthesis tended to rotate toward the surgical resection when subjected to posterior or anterior loads. The amount of tensile and compressive stress caused by the Aramany Class IV obturator prosthesis did not exceed the physiological limits of the maxillary bone tissue. (J Prosthet Dent 2012;107:336-342)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The progression of diabetes and the challenge of daily tasks may result in changes in biomechanical strategies. Descending stairs is a common task that patients have to deal with, however it still has not been properly studied in this population. Objectives: We describe and compare the net joint moments and kinematics of the lower limbs in diabetic individuals with and without peripheral neuropathy and healthy controls during stair descent. Method: Forty-two adults were assessed: control group (13), diabetic group (14), and neuropathic diabetic group (15). The flexor and extensor net moment peaks and joint angles of the hip, knee, and ankle were described and compared in terms of effect size and ANOVAs (p<0.05). Results: Both diabetic groups presented greater dorsiflexion [large effect size] and a smaller hip extensor moment [large effect size] in the weight acceptance phase. In the propulsion phase, diabetics with and without neuropathy showed a greater hip flexor moment [large effect size] and smaller ankle extension [large effect size]. Conclusion: Diabetic patients, even without neuropathy, revealed poor eccentric control in the weight acceptance phase, and in the propulsion phase, they showed a different hip strategy, where they chose to take the leg off the ground using more flexion torque at the hip instead of using a proper ankle extension function.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate biomechanical changes measured with the ORA (Ocular Response Analyzer (R); Reichert Ophthalmic Instruments, Buffalo, New York, USA) after Lasik with the Moria One Use Plus and to compare the biomechanics changes after myopic and hyperopic ablations. Methods: Fourteeneyes for hyperopia (H) and 19 eyes for myopia (M) were evaluated with the ORA preoperatively and 1 month after Lasik with thin flap (100 microns) using SBK-OUP (Sub-Bowman Keratomileusis-One Use Plus, Moria (R)). CH (Corneal Hysteresis), CRF (Corneal Resistance Factor), IOPg (gold-standard, Goldmann correlated Intraocular pressure), IOPcc (Corneal compensated Intraocular pressure) and more 38 variables derived from the corneal biomechanical response signal of the ORA were analyzed. The Wilcoxon test was used to assess differences between the variables before and after surgery for each group and the differences between the pre and postoperative (1 month) myopic eyes were compared with those obtained in hyperopic eyes, using the Mann-Whitney test. Results: There was a significant difference before and after Lasik in myopic and hyperopic eyes in IOPg (Wilcoxon, p<0.05), but not in IOPcc. Only myopic eyes showed a significant difference in CH and CRF measurements before and after LASIK, as well as 9 other biomechanical parameters (aspect1, h1, dive1, path1, p1area1, W11, H11, and w2 path11; Wilcoxon, p<0, 05), 8 of these being related to the first sign of flattening. Five parameters related to the sign of the second applanation showed significant variation only in the eyes before and after hyperopic Lasik (aspect2, h2, dive2, mslew2 and H21; Wilcoxon, p<0,05). There was a difference in both myopic and hyperopic on three parameters related to the applanation signal areas (p1area, and p2area p2area1; Wilcoxon, p<0.05). Differences in IOPg and p1area, before and after surgery were significantly higher in myopic eyes than in hyperopic eyes (Mann-Whitey, p<0.05). Conclusion: There are several significant differences in biomechanical parameters after Lasik with Moria OUP_SBK. Overall, the impact of myopic LASIK on corneal biomechanics is higher than of hyperopic Lasik. The parameters derived from the first sign of the ORA are more affected in myopic LASIK, whereas parameters derived from the second applanation are more affected in hyperopic LASIK.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Recent studies have shown an important reduction of joint overload during locomotion in elderly women with knee osteoarthritis (OA) after short- term use of minimalist shoes. Our aim is to investigate the chronic effect of inexpensive and minimalist footwear on the clinical and functional aspects of OA and gait biomechanics of elderly women with knee OA. Methods/Design: Fifty-six elderly women with knee OA grade 2 or 3 (Kellgren and Lawrence) are randomized into blocks and allocated to either the intervention group, which will use flexible, non-heeled shoes-Moleca (R)-for six months for at least six hours daily, or the control group, which could not use these shoes. Neither group is undergoing physical therapy treatment throughout the intervention period. Moleca (R) is a women's double canvas, flexible, flat walking shoe without heels, with a 5-mm anti-slip rubber sole and a 3-mm internal wedge of ethylene vinyl acetate. Both groups will be followed for six months and will be assessed at baseline condition, after three months, and after six months (end of intervention). All the assessments will be performed by a physiotherapist that is blind to the group allocation. The primary outcome is the pain Western Ontario and McMaster Universities Osteoarthritis (WOMAC) score. The secondary outcomes are global WOMAC score; joint stiffness and disability WOMAC scores; knee pain with a visual analogue scale; walking distance in the six-minute walk test; Lequesne score; amount and frequency (number of days) of paracetamol (500 mg) intake over six months; knee adduction moment during gait; global medical assessment score; and global patient auto-assessment score. At baseline, all patients receive a diary to record the hours of daily use of the footwear intervention; every two weeks, the same physiotherapist makes phone calls to all patients in order to verify adherence to treatment. The statistical analysis will be based on intention to treat analysis, as well as general linear models of analysis of variance for repeated measure to detect treatment-time interactions (alpha = 5%). Discussion: This is the first randomized, clinical trial protocol to assess the chronic effect of minimalist footwear on the clinical and functional aspects and gait biomechanics of elderly women with knee osteoarthritis. We expect that the use of Moleca (R) shoes for six months will provide pain relief, reduction of the knee adduction moment when walking, and improve joint function in elderly women with knee OA, and that the treatment, thus, can be considered another inexpensive and easy-to-use option for conservative OA treatment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objetives: Determine the stability of tibial and femoral components of 20 cementless knee arthroplasties with rotating platform. Methods: The 20 patients (20 knees) underwent an analysis of dynamic radiographs with an image amplifier and maneuvers of varus and valgus which were compared to static frontal and lateral radiographs of the knees and analyzed by two experienced surgeons in a double-blind way. Results: We could observe in this study that both methods showed very similar results for the stability of the tibial and femoral components (p<0.001) using the Kappa method for comparison. Conclusion: The tibial component was more unstable in relation to the femoral component in both static and dynamic studies. Level of Evidence IV, Case Series.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to analyze the rat temporomandibular joint (TMJ) synovial membrane at different ages using light, scanning, and transmission electron microscopy. Under light microscopic analysis, the TMJ structures were observed such as condyle, capsule, disk, the synovial membrane collagen type, and cells distribution. In the scanning electron microscopy, the synovial membrane surface exhibited a smooth aspect in young animals and there was an increase with ageing in the number of folds. The transmission electron microscopic analysis showed more synoviocytes in the synovial layer in the young group and still a great number of vesicles and cisterns dilation of rough endoplasmic reticulum in the aged group. In the three groups, a dense layer of collagen fibers in the synovial layer and cytoplasmic extensions were clearly seen. It was possible to conclude that synovial membrane structures in aged group showed alterations contributing to the decrease in joint lubrication and in the sliding between disk and joint surfaces. These characteristic will reflect in biomechanics of chewing, and may cause the TMJ disorders, currently observed in clinical processes. Microsc. Res. Tech. (c) 2012 Wiley Periodicals, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Study Design. Ex vivo study of the mechanical performance of cylindrical and dual-core pedicle screws after insertion, removal, and reinsertion in the same hole. Objective. To evaluate the effect of repeated use of same screw hole on the insertion torque and the retentive strength of the cylindrical and dual-core screws. Summary of Background Data. Insertion and removal of pedicle screws is sometimes necessary during surgical procedure to assess the integrity of the pilot-hole wall. However, this maneuver may compromise the implant-holding capacity. Methods. Sixty thoracolombar vertebrae (T13-L5), harvested from 10 healthy calves, were used to insert 2 different designs of pedicle screws: cylindrical (5.0-mm outer diameter) and dual-core screws (5.2-mm outer diameter). Three experimental groups were created on the basis of the number of insertions of the screws and 2 subgroups were established according to the core pedicle screw design (dual-core and cylindrical). The insertion torque was measured during initial insertion, second insertion, and third insertion. Pullout screw tests were performed using a universal testing machine to evaluate the pullout strength after initial insertion, second insertion, and third insertion. Results. Significant reductions of 38% in mean insertion torque and 30% in mean pullout strength of dual-core screw were observed between the initial insertion and the third insertion. The cylindrical screw observed significant reductions of 52.5% in mean insertion torque and 42.3% in mean pullout strength between the initial insertion and the third insertion. A reduction of mean insertion torque and pullout strength between the first insertion and the second insertion but without significance was also observed for both types of screws. Conclusion. Insertions and reinsertion of either cylindrical or dual-core pedicle screws have compromised insertion torque and pullout strength of the implants as measured by mechanical tests.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The treatment of a transverse maxillary deficiency in skeletally mature individuals should include surgically assisted rapid palatal expansion. This study evaluated the distribution of stresses that affect the expander's anchor teeth using finite element analysis when the osteotomy is varied. Five virtual models were built and the surgically assisted rapid palatal expansion was simulated. Results showed tension on the lingual face of the teeth and alveolar bone, and compression on the buccal side of the alveolar bone. The subtotal Le Fort I osteotomy combined with intermaxillary suture osteotomy seemed to reduce the dissipation of tensions. Therefore, subtotal Le Fort I osteotomy without a step in the zygomaticomaxillary buttress, combined with intermaxillary suture osteotomy and pterygomaxillary disjunction may be the osteotomy of choice to reduce tensions on anchor teeth, which tend to move mesiobuccally (premolar) and distobuccally (molar)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Treatment of patients with cleft lip and palate is completed with fixed prostheses, removable, total, implants and aims to restore aesthetics, phonetics and function and should be guided by the basic principles of oral rehabilitation, such as physiology, stability, aesthetics, hygiene and the expectations of the patient. In order to obtain longevity of a prosthetic rehabilitation, the periodontal and dental tissue as well as the biomechanics of the prosthesis are to be respected. The purpose of this article is to describe the types of prosthetics treatment, which are performed at HRAC/USP for the rehabilitation of cleft area in adult patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Triassic dinosaurs of Brazil are found in Santa Maria and Caturrita formations, Rio Grande do Sul state, Brazil. There are three species known from the Santa Maria Formation (Staurikosaurus pricei, Saturnalia tupiniquim and Pampadromaeus barberenai), and two from Caturrita Formation (Guaibasaurus candelariensis and Unaysaurus tolentinoi). These dinosaur materials are, for the most part, well preserved and allow for descriptions of musculature and biomechanical studies. The lateral rotation of the Saturnalia femur is corroborated through calculations of muscle moment arms. The enhanced supracetabular crest of Saturnalia, Guaibasaurus, Staurikosaurus, Herrerasaurus ischigualastensis, Efraasia minor and Chormogisaurus novasi suggests that basal dinosaurs may have maintained an inclination of the trunk at least 20º on the horizontal axis. The pectoral girdle articulation of basal sauropodomorphs (Saturnalia and Unaysaurus) was established using a new method, the Clavicular Ring, and the scapular blade remains near 60º on the horizontal axis. This is a plesiomorphic condition among sauropodomorphs and is also seen in the articulated plateosauridae Seitaad ruessi. The Brazilian basal dinosaurs were lightweight with a body mass estimated around 18.5 kg for Staurikosaurus, 6.5 kg for Saturnalia, and 17 kg for Guaibasaurus. Pampadromaeus probably weighed 2.5 kg, but measures of its femur are necessary to confirm this hypothesis. The Triassic dinosaurs from Brazil were diversified but shared some functional aspects that were important in an evolutionary context.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Osteoporosis is a major complication of chronic cholestatic liver disease (CCLD). We evaluated the efficacy of using disodium pamidronate (1.0 mg/kg body weight) for the prevention (Pr) or treatment (Tr) of cholestasis-induced osteoporosis in male Wistar rats: sham-operated (Sham = 12); bile duct-ligated (Bi = 15); bile duct-ligated animals previously treated with pamidronate before and 1 month after surgery (Pr = 9); bile duct-ligated animals treated with pamidronate 1 month after surgery (Tr = 9). Rats were sacrificed 8 weeks after surgery. Immunohistochemical expression of IGF-I and GH receptor was determined in the proximal growth plate cartilage of the left tibia. Histomorphometric analysis was performed in the right tibia and the right femur was used for biomechanical analysis. Bone material volume over tissue volume (BV/TV) was significantly affected by CCLD (Sham = 18.1 ± 3.2 vs Bi = 10.6 ± 2.2%) and pamidronate successfully increased bone volume. However, pamidronate administered in a preventive regimen presented no additional benefit on bone volume compared to secondary treatment (BV/TV: Pr = 39.4 ± 12.0; Tr = 41.2 ± 12.7%). Moreover, the force on the momentum of fracture was significantly reduced in Pr rats (Sham = 116.6 ± 23.0; Bi = 94.6 ± 33.8; Pr = 82.9 ± 22.8; Tr = 92.5 ± 29.5 N; P < 0.05, Sham vs Pr). Thus, CCLD had a significant impact on bone histomorphometric parameters and pamidronate was highly effective in increasing bone mass in CCLD; however, preventive therapy with pamidronate has no advantage regarding bone fragility.