23 resultados para Vocal loading
Resumo:
Objective: Parameters to distinguish normal from deviant voices in early childhood have not been established. The current study sought to auditorily and acoustically characterize voices of children, and to study the relationship between vocal behavior reported by teachers and the presence of vocal aberrations. Methods: One hundred children between four and 6 years and 11 months, who attended early childhood educational institutions, were included. The sample comprised 50 children with normal voices (NVG) and 50 with deviant voices (DVG) matched by gender and age. All participants were submitted to auditory and acoustic analysis of vocal quality and had their vocal behaviors assessed by teachers through a specific protocol. Results: DVG had a higher incidence of breathiness (p < 0.001) and roughness (p < 0.001), but not vocal strain (p = 0.546), which was similar in both groups. The average F-0 was lower in the DVG and a higher noise component was observed in this group as well. Regarding the protocol used "Aspects Related to Phonotrauma - Children's Protocol", higher means were observed for children from DVG in all analyzed aspects and also on the overall means (DVG = 2.15; NVG = 1.12, p < 0.001). In NVG, a higher incidence of vocal behavior without alterations or with discrete alterations was observed, whereas a higher incidence of moderate, severe or extreme alterations of vocal behavior was observed in DVG. Conclusions: Perceptual assessment of voice, vocal acoustic parameters (F-0, noise and GNE), and aspects related to vocal trauma and vocal behavior differentiated the groups of children with normal voice and deviant voice. (C) 2012 Elsevier Ireland Ltd. All rights reserved.
Resumo:
The aim this work was to compare the distribution of cellular phenotypes of the LF in the FVC to the ones in the subglottic region in pediatric autopsy, relating this distribution to age and different causes of death. We analyzed 60 larynges of newborns and children autopsied in the period from 1993 to 2003. The fragments were prepared in order to perform histochemical and immunohistochemical techniques. The morphological analysis showed cases that presented LF only in FVC (35%), LF only in the subglottic region (20%), lack of LF in FVC (30%) and lymphoid aggregates, which did not characterize an LF (15%). The cases of LF in the subglottic region were significantly younger compared to the ones that presented LF in the FVC (p = 0.017). The LF in the subglottic region was bigger than the LF in the FVC (p = 0.020). There was no significant difference between the cause of death and cellular phenotype for both FVC and the subglottic region. In conclusion, the cells that make up the LF in the FVC in newborns and children younger than one year have functional characteristics similar to LF cells in the subglottic region, suggesting that there are similarities with LALT. (c) 2012 Elsevier GmbH. All rights reserved.
Resumo:
Primary voice production occurs in the larynx through vibrational movements carried out by vocal folds. However, many problems can affect this complex system resulting in voice disorders. In this context, time-frequency-shape analysis based on embedding phase space plots and nonlinear dynamics methods have been used to evaluate the vocal fold dynamics during phonation. For this purpose, the present work used high-speed video to record the vocal fold movements of three subjects and extract the glottal area time series using an image segmentation algorithm. This signal is used for an optimization method which combines genetic algorithms and a quasi-Newton method to optimize the parameters of a biomechanical model of vocal folds based on lumped elements (masses, springs and dampers). After optimization, this model is capable of simulating the dynamics of recorded vocal folds and their glottal pulse. Bifurcation diagrams and phase space analysis were used to evaluate the behavior of this deterministic system in different circumstances. The results showed that this methodology can be used to extract some physiological parameters of vocal folds and reproduce some complex behaviors of these structures contributing to the scientific and clinical evaluation of voice production. (C) 2010 Elsevier Inc. All rights reserved.
Resumo:
Objective: To evaluate healing time before loading, areas compression and tension and location of insertion on mini-implant stability. Design: Six minipigs were used. Each animal received 3 mini-implants in each quadrant: 1 mini-implant was used as an unloaded control (G1, n = 24); the other 2 were loaded with 150 g-force at three time intervals (G2: immediate loading, G3: after 15 days and G4: after 30 days), with 16 mini-implant in each experimental group. After 120 days, tissue blocks of the areas of interest were harvested. Clinical analysis (exact Fisher test) determined the survival rate. Histological analysis (Kontron KS 300TM, Zeiss) quantified the fractional bone-toimplant contact (%BIC) and bone area (%BA) at each healing time point, areas of interest, and insertion site (ANOVA and t tests for dependent and independent samples). Results: The mini-implant survival rates were G1: 71%, G2: 50%, G3: 75% and G4: 63%, with no statistical differences between them. The groups presented similar %BIC and %BA. There were no differences between the compression and tension sides or maxillary and mandibular insertion sites. Conclusions: These results suggest that low-intensity immediate or early orthodontic loading does not affect mini-implant stability, because similar histomorphometric results were observed for all the groups, with partial osseointegration of the mini-implants present.
Resumo:
Bone remodeling is affected by mechanical loading and inflammatory mediators, including chemokines. The chemokine (C–C motif) ligand 3 (CCL3) is involved in bone remodeling by binding to C–C chemokine receptors 1 and 5 (CCR1 and CCR5) expressed on osteoclasts and osteoblasts. Our group has previously demonstrated that CCR5 down-regulates mechanical loading-induced bone resorption. Thus, the present study aimed to investigate the role of CCR1 and CCL3 in bone remodeling induced by mechanical loading during orthodontic tooth movement in mice. Our results showed that bone remodeling was significantly decreased in CCL3−/− and CCR1−/− mice and in animals treated with Met-RANTES (an antagonist of CCR5 and CCR1). mRNA levels of receptor activator of nuclear factor kappa-B (RANK), its ligand RANKL, tumor necrosis factor alpha (TNF-α) and RANKL/osteoprotegerin (OPG) ratio were diminished in the periodontium of CCL3−/− mice and in the group treated with Met-RANTES. Met-RANTES treatment also reduced the levels of cathepsin K and metalloproteinase 13 (MMP13). The expression of the osteoblast markers runt-related transcription factor 2 (RUNX2) and periostin was decreased, while osteocalcin (OCN) was augmented in CCL3−/− and Met-RANTES-treated mice. Altogether, these findings show that CCR1 is pivotal for bone remodeling induced by mechanical loading during orthodontic tooth movement and these actions depend, at least in part, on CCL3.
Resumo:
This paper emphasizes the influence of micro mechanisms of failure of a cellular material on its phenomenological response. Most of the applications of cellular materials comprise a compression loading. Thus, the study focuses on the influence of the anisotropy in the mechanical behavior of cellular material under cyclic compression loadings. For this study, a Digital Image Correlation (DIC) technique (named Correli) was applied, as well as SEM (Scanning Electron Microscopy) images were analyzed. The experimental results are discussed in detail for a closed-cell rigid poly (vinyl chloride) (PVC) foam, showing stress-strain curves in different directions and why the material can be assumed as transversely isotropic. Besides, the present paper shows elastic and plastic Poisson's ratios measured in different planes, explaining why the plastic Poisson's ratios approach to zero. Yield fronts created by the compression loadings in different directions and the influence of spring-back phenomenon on hardening curves are commented, also.
Resumo:
OBJETIVO: Realizar uma revisão sistemática de pesquisas relacionadas às características vocais de crianças ou adultos com deficiência auditiva usuários de implante coclear. ESTRATÉGIAS DE PESQUISA: Foi realizada uma busca com os descritores voz, qualidade da voz e implante coclear, e seus respectivos correspondentes na língua inglesa, nas bases de dados Web of Science, Bireme, portal de teses e dissertações da USP e banco de teses e dissertações da CAPES. CRITÉRIOS DE SELEÇÃO: Os critérios adotados incluíram título condizente com a proposta deste estudo, casuística necessariamente englobando crianças ou adultos com deficiência auditiva de grau severo a profundo, pré ou pós-linguais, usuários de implante coclear e que tenham passado por análise perceptivo-auditiva e/ou acústica da qualidade vocal. RESULTADOS: Vinte e sete trabalhos foram classificados seguindo-se os níveis de evidências e indicadores de qualidade empregados pela American Speech-Language-Hearing Association (ASHA). Os desenhos dos trabalhos analisados foram considerados de média e baixa evidência científica. Seis trabalhos foram classificados como nível de evidência IIb, 20 como III, e um como IV. CONCLUSÃO: A qualidade vocal da criança ou adulto com deficiência auditiva usuário de implante coclear tem sido estudada em pequena escala. Não há um número efetivo de estudos com alto índice de evidência que demonstrem com precisão os efeitos do implante coclear na qualidade vocal desses indivíduos.
Resumo:
This work presents an investigation of the ductile tearing properties for a girth weld made of an API 5L X80 pipeline steel using experimentally measured crack growth resistance curves. Use of these materials is motivated by the increasing demand in the number of applications for manufacturing high strength pipes for the oil and gas industry including marine applications and steel catenary risers. Testing of the pipeline girth welds employed side-grooved, clamped SE(T) specimens and shallow crack bend SE(B) specimens with a weld centerline notch to determine the crack growth resistance curves based upon the unloading compliance (UC) method using the single specimen technique. Recently developed compliance functions and η-factors applicable for SE(T) and SE(B) fracture specimens with homogeneous material and overmatched welds are introduced to determine crack growth resistance data from laboratory measurements of load-displacement records.