20 resultados para Variable Sampling Interval Control Charts


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Exercise training (ET) has been used as a nonpharmacological strategy for treatment of diabetes and myocardial infarction (MI) separately. We evaluated the effects ET on functional and molecular left ventricular (LV) parameters as well as on autonomic function and mortality in diabetics after MI. Methods and Results: Male Wistar rats were divided into control (C), sedentary-diabetic infarcted (SDI), and trained-diabetic infarcted (TDI) groups. MI was induced after 15 days of streptozotocin-diabetes induction. Seven days after MI, the trained group underwent ET protocol (90 days, 50-70% maximal oxygen consumption-VO(2)max). LV function was evaluated noninvasively and invasively; baroreflex sensitivity, pulse interval variability, cardiac output, tissue blood flows, VEGF mRNA and protein, HIF1-alpha mRNA, and Ca2+ handling proteins were measured. MI area was reduced in TDI (21 +/- 4%) compared with SDI (38 +/- 4%). ET induced improvement in cardiac function, hemodynamics, and tissue blood flows. These changes were probable consequences of a better expression of Ca2+ handling proteins, increased VEGF mRNA and protein expression as well as improvement in autonomic function, that resulted in reduction of mortality in TDI (33%) compared with SDI (68%) animals. Conclusions: ET reduced cardiac and peripheral dysfunction and preserved autonomic control in diabetic infarcted rats. Consequently, these changes resulted in improved VO(2)max and survival after MI. (J Cardiac Fail 2012; 18:734-744)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract Background Air pollution in São Paulo is constantly being measured by the State of Sao Paulo Environmental Agency, however there is no information on the variation between places with different traffic densities. This study was intended to identify a gradient of exposure to traffic-related air pollution within different areas in São Paulo to provide information for future epidemiological studies. Methods We measured NO2 using Palmes' diffusion tubes in 36 sites on streets chosen to be representative of different road types and traffic densities in São Paulo in two one-week periods (July and August 2000). In each study period, two tubes were installed in each site, and two additional tubes were installed in 10 control sites. Results Average NO2 concentrations were related to traffic density, observed on the spot, to number of vehicles counted, and to traffic density strata defined by the city Traffic Engineering Company (CET). Average NO2concentrations were 63μg/m3 and 49μg/m3 in the first and second periods, respectively. Dividing the sites by the observed traffic density, we found: heavy traffic (n = 17): 64μg/m3 (95% CI: 59μg/m3 – 68μg/m3); local traffic (n = 16): 48μg/m3 (95% CI: 44μg/m3 – 52μg/m3) (p < 0.001). Conclusion The differences in NO2 levels between heavy and local traffic sites are large enough to suggest the use of a more refined classification of exposure in epidemiological studies in the city. Number of vehicles counted, traffic density observed on the spot and traffic density strata defined by the CET might be used as a proxy for traffic exposure in São Paulo when more accurate measurements are not available.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper the influence of a secondary variable as a function of the correlation with the primary variable for collocated cokriging is examined. For this study five exhaustive data sets were generated in computer, from which samples with 60 and 104 data points were drawn using the stratified random sampling method. These exhaustive data sets were generated departing from a pair of primary and secondary variables showing a good correlation. Then successive sets were generated by adding an amount of white noise in such a way that the correlation gets poorer. Using these samples, it was possible to find out how primary and secondary information is used to estimate an unsampled location according to the correlation level.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Variable rate sprinklers (VRS) have been developed to promote localized water application of irrigated areas. In Precision Irrigation, VRS permits better control of flow adjustment and, at the same time, provides satisfactory radial distribution profiles for various pressures and flow rates are really necessary. The objective of this work was to evaluate the performance and radial distribution profiles of a developed VRS which varies the nozzle cross sectional area by moving a pin in or out using a stepper motor. Field tests were performed under different conditions of service pressure, rotation angles imposed on the pin and flow rate which resulted in maximal water throw radiuses ranging from 7.30 to 10.38 m. In the experiments in which the service pressure remained constant, the maximal throw radius varied from 7.96 to 8.91 m. Averages were used of repetitions performed under conditions without wind or with winds less than 1.3 m s-1. The VRS with the four stream deflector resulted in greater water application throw radius compared to the six stream deflector. However, the six stream deflector had greater precipitation intensities, as well as better distribution. Thus, selection of the deflector to be utilized should be based on project requirements, respecting the difference in the obtained results. With a small opening of the nozzle, the VRS produced small water droplets that visually presented applicability for foliar chemigation. Regarding the comparison between the estimated and observed flow rates, the stepper motor produced excellent results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: Rapid maxillary expansion (RME) for the treatment of maxillary deficiency and posterior crossbite may induce changes in the vertical dimension. Expanders with occlusal splints have been developed to minimize unwanted vertical effects. OBJECTIVE: This preliminary study used cephalometri radiographs to evaluate the vertical effects of RME using a Hyrax appliance in children with maxillary deficiency. METHOD: Twenty-six patients (11 boys; mean age = 8 years and 5 months) with maxillary deficiency and posterior crossbite were treated using a Hyrax appliance with an acrylic occlusal splint. Radiographs and cephalometric studies were performed before the beginning of the treatment (T1) and after RME active time (T2), at a mean interval of 7 months. Results were compared with normative values. RESULTS AND CONCLUSIONS: At the end of treatment, there were no statistically significant changes, and measurements were similar to the normative values. Data showed that there were no significant effects on vertical growth, which suggests that appliances with occlusal splints may be used to correct transverse deficiencies regardless of the patient's growth pattern.