30 resultados para Respiratory-tract Infection


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: The analysis of exhaled breath condensate (EBC) is a non-invasive technique that enables the determination of several volatile and nonvolatile substances produced in the respiratory tract, whose measurement may be useful for the diagnosis and monitoring of several respiratory diseases. Objective: The aim of this study was to produce a low-cost reusable device in order to sample exhaled breath condensate in healthy adult volunteers, and to determine the concentration of nitric oxide in the sample collected. Material and methods: The apparatus was made with a U-shaped tube of borosilicate glass. The tube was placed in a container with ice, and unidirectional respiratory valves were fitted to the distal end. Afterwards, nitric oxide was measured in the exhaled breath condensate (EBC) by chemiluminescence. Results: The total cost of the device was $120.20. EBC samples were obtained from 116 volunteers of both sexes, aged between 20 and 70. The mean volume of exhaled breath condensate collected during 10 minutes was 1.0 +/- 0.6 mL, and the mean level of nitric oxide was 12.99 +/- 14.38 mu M (median 8.72 mu M). There was no correlation between the nitric oxide levels in the exhaled breath condensate and age or gender. Conclusion: We demonstrate that it is possible to fabricate a low-cost, efficient, reusable device in order to collect and determine nitric oxide levels in EBC. We have identified no correlation between the nitric oxide levels present in the EBC obtained with this method with either age or sex. (C) 2011 SEPAR. Published by Elsevier Espana, S.L. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: To estimate the frequency and describe the clinical characteristics and respective treatments of previous history of wheezing. Methods: Infants aged 6-23 months with upper respiratory tract complaints and reporting previous wheezing were followed-up retrospectively. Data were registered on a validated standardized form. Results: Out of 451 infants, 164 (36.4%; 95%CI: 31.9-41.0) had a report of prior history of wheezing, 148 (32.8%; 95%CI: 28.5-37.4) during the first year of life. The mean age at the first episode of wheezing was 5.3 +/- 3.9 months. Among those who had had their first episode before 12 months of age, 38.5% reported 3 to 6 episodes and 14.2% > 6 episodes. Mean age at first episode was lower for those with a >= 3 episodes in comparison with those with <= 2 episodes (3.2 +/- 2.7 vs. 5.7 +/- 2.5 months, p < 0.001). Conclusion: One third of the infants reported wheezing during the first year of life. The earlier the first episode occurs, the more frequently wheezing recurs.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: Duplex system is one of the most common anomalies of upper urinary tract. Anatomical and clinical presentation determine its treatment. Usually, the upper moiety has a poor function and requires resection, but when it is not significantly impaired, preservation is recommended. Laparoscopic reconstruction with upper pole preservation is presented as an alternative treatment. Materials and Methods: Four female patients with duplex system, one presenting with recurrent urinary tract infection and the others with urinary incontinence associated to infrasphincteric ectopic ureter, were treated. Surgical procedure envolved a laparoscopic ureteropyeloanastomosis of the upper pole ureter to the pelvis of the lower moiety, with prior insertion of a double J stent. Results: Surgical time varied from 120 to 150 minutes, with minimal blood loss in all cases. Follow-up varied from 15 to 30 months, with resolution of the clinical symptoms and preservation of the upper moiety function. Conclusion: Laparoscopic ureteropyeloanatomosis is a feasible and safe minimally invasive option in the treatment of duplex system.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Chronic Obstructive Pulmonary Disease (COPD) can be briefly described as air flow limitation and chronic dyspnea associated to an inflammatory response of the respiratory tract to noxious particles and gases. Its main feature is the obstruction of airflow and consequent chronic dyspnea. Despite recent advances, and the development of new therapeutic, medical and clinical approaches, a curative therapy is yet to be achieved. Therapies involving the use of tissue-specific or donor derived cells present a promising alternative in the treatment of degenerative diseases and injuries. Recent studies demonstrate that mesenchymal stem cells have the capacity to modulate immune responses in acute lung injury and pulmonary fibrosis in animal models, as well as in human patients. Due to these aspects, different groups raised the possibility that the stem cells from different sources, such as those found in bone marrow or adipose tissue, could act preventing the emphysematous lesion progression. In this paper, it is proposed a review of the current state of the art and future perspectives on the use of cell therapy in obstructive lung diseases.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Hydroquinone (HQ) is the main oxidative substance in cigarette smoke and a toxic product of benzene biotransformation. Although the respiratory tract is an inlet pathway of HQ exposure, its effect on airway muscle responsiveness has not been assessed. We thus investigated the effects of low dose in vivo HQ-exposure on tracheal responsiveness to a muscarinic receptor agonist. Male Swiss mice were exposed to aerosolised 5% ethanol/saline solution (HQ vehicle; control) or 0.04 ppm HQ (1 h/day for 5 days) and tracheal rings were collected 1 h after the last exposure. HQ exposure caused tracheal hyper-responsiveness to methacholine (MCh), which was abolished by mechanical removal of the epithelium. This hyperresponsiveness was not dependent on neutrophil infiltration, but on tumour necrosis factor (TNF) secretion by epithelial cells. This conclusion was based on the following data: (1) trachea from HQ-exposed mice presented a higher amount of TNF, which was abrogated following removal of the epithelium; (2) the trachea hyperresponsiveness and TNF levels were attenuated by in vivo chlorpromazine (CPZ) treatment, an inhibitor of TNF synthesis. The involvement of HQ-induced TNF secretion in trachea mast cell degranulation was also demonstrated by the partial reversion of tracheal hyperresponsiveness in sodium cromoglicate-treated animals, and the in vivo HQ-exposure-induced degranulation of trachea connective tissue and mucosal mast cells, which was reversed by CPZ treatment. Our data show that in vivo HQ exposure indirectly exacerbates the parasympathetic-induced contraction of airway smooth muscle cells, mediated by TNF secreted by tracheal epithelial cells, clearly showing the link between environmental HQ exposure and the reactivity of airways. (C) 2012 Elsevier Ireland Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Aerobic conditioning (AC) performed either during or after sensitization reduces allergic inflammation in mice; however, the effects of AC performed before and during allergic sensitization on airway inflammation are unknown. Mice were divided into Control, AC, OVA, and AC + OVA groups. Mice were trained in a treadmill followed by either ovalbumin (OVA) sensitization or saline administration. Peribronchial inflammation, OVA-specific IgE and IgG1 titers, the expression of Th1 and Th2 cytokines, and airway remodeling were evaluated, as well as the expression of Eotaxin, RANTES, ICAM-1, VCAM-1, TGF-beta and VEGF. Aerobic conditioning performed before and during allergic sensitization displayed an inhibitory effect on the OVA-induced migration of eosinophils and lymphocytes to the airways, a reduction of IgE and IgG1 titers and an inhibition of the expression of Th2 cytokines. The AC + OVA group also demonstrated reduced expression of ICAM-1, VCAM-1, RANTES, TGF-beta and VEGF, as well as decreased airway remodeling (p < 0.05). The effects of AC before and during the sensitization process inhibit allergic airway inflammation and reduce the production of Th2 cytokines and allergen-specific IgE and IgG1.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE: To analyze the impact of intra-urban atmospheric conditions on circulatory and respiratory diseases in elder adults. METHODS: Cross-sectional study based on data from 33,212 hospital admissions in adults over 60 years in the city of Sao Paulo, southeastern Brazil, from 2003 to 2007. The association between atmospheric variables from Congonhas airport and bioclimatic index, Physiological Equivalent Temperature, was analyzed according to the district's socioenvironmental profile. Descriptive statistical analysis and regression models were used. RESULTS: There was an increase in hospital admissions due to circulatory diseases as average and lowest temperatures decreased. The likelihood of being admitted to the hospital increased by 12% with 1 degrees C decrease in the bioclimatic index and with 1 degrees C increase in the highest temperatures in the group with lower socioenvironmental conditions. The risk of admission due to respiratory diseases increased with inadequate air quality in districts with higher socioenvironmental conditions. CONCLUSIONS: The associations between morbidity and climate variables and the comfort index varied in different groups and diseases. Lower and higher temperatures increased the risk of hospital admission in the elderly. Districts with lower socioenvironmental conditions showed greater adverse health impacts.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We investigated the clinical impact of human coronaviruses (HCoV) OC43, 229E, HKU1 and NL63 in pediatric patients with cystic fibrosis (CF) during routine and exacerbation visits. A total of 408 nasopharyngeal aspirate samples were obtained from 103 patients over a 1-year period. Samples positive for HCoV were submitted for nucleotide sequencing to determine the species. Nineteen samples (4.65%) were positive for HCoV, of which 8 were positive for NL63, 6 for OC43, 4 for HKU1, and 1 for 229E. Identification of HCoV was not associated with an increased rate of respiratory exacerbations, but NL63-positive patients had higher exacerbation rates than patients who were positive for other HCoV species.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The study was designed to investigate the impact of air pollution on monthly inhalation/nebulization procedures in Ribeirao Preto, Sao Paulo State, Brazil, from 2004 to 2010. To assess the relationship between the procedures and particulate matter (PM10) a Bayesian Poisson regression model was used, including a random factor that captured extra-Poisson variability between counts. Particulate matter was associated with the monthly number of inhalation/nebulization procedures, but the inclusion of covariates (temperature, precipitation, and season of the year) suggests a possible confounding effect. Although other studies have linked particulate matter to an increasing number of visits due to respiratory morbidity, the results of this study suggest that such associations should be interpreted with caution.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: To determine the minimum inhibitory concentrations (MICs) of parenteral penicillin and moxifloxacin against Streptococcus pneumoniae strains isolated at a hospital center. Methods: In-vitro, prospective study involving 100 S. pneumoniae isolates collected from patients who had been treated, between October of 2008 and July of 2010, at the Hospital das Clinicas complex of the University of Sao Paulo School of Medicine, located in the city of Sao Paulo, Brazil. The isolates were obtained from respiratory tract cultures or blood samples unrelated to meningeal infections, and they were tested for penicillin and moxifloxacin susceptibility by E-test. The MIC category interpretations were based on updated standards. Results: All isolates were fully susceptible to parenteral penicillin (MIC <= 2 mu g/mL), and, consequently, they were also susceptible to amoxicillin, ampicillin, third/fourth generation cephalosporins, and ertapenem. Of the S. pneumoniae strains, 99% were also susceptible to moxifloxacin, and only one strain showed an MIC = 1.5 mu g/mL (intermediate). Conclusions: Our results showed high susceptibility rates to parenteral penicillin and moxifloxacin among S. pneumoniae isolates unrelated to meningitis, which differs from international reports. Reports on penicillin resistance should be based on updated breakpoints for non-meningitis isolates in order to guide the selection of an antimicrobial therapy and to improve the prediction of the clinical outcomes.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: Human respiratory syncytial virus (HRSV) is one of the major etiologic agents of respiratory tract infections among children worldwide. Methodology/Principal Findings: Here through a comprehensive analysis of the two major HRSV groups A and B (n = 1983) which comprise of several genotypes, we present a complex pattern of population dynamics of HRSV over a time period of 50 years (1956-2006). Circulation pattern of HRSV revealed a series of expansions and fluctuations of co-circulating lineages with a predominance of HRSVA. Positively selected amino acid substitutions of the G glycoprotein occurred upon population growth of GB3 with a 60-nucleotide insertion (GB3 Insert), while other genotypes acquired substitutions upon both population growth and decrease, thus possibly reflecting a role for immune selected epitopes in linkage to the traced substitution sites that may have important relevance for vaccine design. Analysis evidenced the co-circulation and predominance of distinct HRSV genotypes in Brazil and suggested a year-round presence of the virus. In Brazil, GA2 and GA5 were the main culprits of HRSV outbreaks until recently, when the GB3 Insert became highly prevalent. Using Bayesian methods, we determined the dispersal patterns of genotypes through several inferred migratory routes. Conclusions/Significance: Genotypes spread across continents and between neighboring areas. Crucially, genotypes also remained at any given region for extended periods, independent of seasonal outbreaks possibly maintained by re-infecting the general population.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJETIVO: Estimar a prevalência de bronquite aguda, rinite e sinusite em crianças e adolescentes e identificar fatores associados. MÉTODOS: Estudo transversal, de base populacional. Foi realizado inquérito domiciliar com 1.185 crianças e adolescentes de São Paulo, SP, de 2008 a 2009. Os participantes foram selecionados a partir de amostragem probabilística, estratificada por sexo e idade e por conglomerados em dois estágios. Para análise ajustada foi realizada regressão múltipla de Poisson. RESULTADOS: Dos entrevistados, 7,3% referiram bronquite aguda, 22,6% rinite e 15,3% sinusite. Após análise ajustada, associaram-se à bronquite aguda auto-referida: idade de zero a quatro anos (RP = 17,86; IC95%: 3,65;90,91), cinco a nove anos (RP = 37,04; IC95%: 8,13;166,67), dez a 14 anos (RP = 20,83; IC95%: 4,93;90,91), referir ter alergia (RP = 3,12; IC95%: 1,70;5,73), cor da pele preta/parda (RP = 2,29; IC95%: 1,21;4,35) e morar em domicílio com um a três cômodos (RP = 1,85; IC95%: 1,17;2,94); à rinite auto-referida: idade dez a 14 anos (RP = 2,77; IC95%: 1,60;4,78), 15 a 19 anos (RP = 2,58; IC95%: 1,52;4,39), referir ter alergia (RP = 4,32; IC95%: 2,79;6,70), referir ter asma (RP = 2,30; IC95%: 1,30;4,10) e morar em apartamento (RP = 1,70; IC95%: 1,06;2,73); à sinusite auto-referida: idade cinco a nove anos (RP = 2,44; IC95%: 1,09;5,43), dez a 14 anos (RP = 2,99; IC95%: 1,36;6,58), 15 a 19 anos (RP = 3,62; IC95%: 1,68;7,81), referir ter alergia (RP = 2,23; IC95%: 1,41;3,52) e apresentar obesidade (RP = 4,42; IC95%: 1,56;12,50). CONCLUSÕES: As doenças respiratórias foram mais prevalentes em grupos populacionais com características definidas, como grupo etário, doenças auto-referidas, tipo de moradia e obesidade.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE: To analyze the impact of intra-urban atmospheric conditions on circulatory and respiratory diseases in elder adults. METHODS: Cross-sectional study based on data from 33,212 hospital admissions in adults over 60 years in the city of São Paulo, southeastern Brazil, from 2003 to 2007. The association between atmospheric variables from Congonhas airport and bioclimatic index, Physiological Equivalent Temperature, was analyzed according to the district's socioenvironmental profile. Descriptive statistical analysis and regression models were used. RESULTS: There was an increase in hospital admissions due to circulatory diseases as average and lowest temperatures decreased. The likelihood of being admitted to the hospital increased by 12% with 1ºC decrease in the bioclimatic index and with 1ºC increase in the highest temperatures in the group with lower socioenvironmental conditions. The risk of admission due to respiratory diseases increased with inadequate air quality in districts with higher socioenvironmental conditions. CONCLUSIONS: The associations between morbidity and climate variables and the comfort index varied in different groups and diseases. Lower and higher temperatures increased the risk of hospital admission in the elderly. Districts with lower socioenvironmental conditions showed greater adverse health impacts.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The study was designed to investigate the impact of air pollution on monthly inhalation/nebulization procedures in Ribeirão Preto, São Paulo State, Brazil, from 2004 to 2010. To assess the relationship between the procedures and particulate matter (PM10) a Bayesian Poisson regression model was used, including a random factor that captured extra-Poisson variability between counts. Particulate matter was associated with the monthly number of inhalation/nebulization procedures, but the inclusion of covariates (temperature, precipitation, and season of the year) suggests a possible confounding effect. Although other studies have linked particulate matter to an increasing number of visits due to respiratory morbidity, the results of this study suggest that such associations should be interpreted with caution.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A poluição atmosférica encontra-se presente nos mais diferentes cenários ao longo dos últimos 250 anos, desde que a Revolução Industrial acelerou o processo de emissão de poluentes que, até então, estava limitado ao uso doméstico de combustíveis vegetais e minerais e às emissões vulcânicas intermitentes. Hoje, aproximadamente 50% da população do planeta vivem em cidades e aglomerados urbanos e estão expostas a níveis progressivamente maiores de poluentes do ar. Este estudo é uma revisão não sistemática sobre os diferentes tipos e fontes de poluentes do ar e os efeitos respiratórios atribuídos à exposição a esses contaminantes. Podem ser creditados aos poluentes particulados e gasosos, emitidos por diferentes fontes, aumentos nos sintomas de doenças, na procura por atendimentos em serviços de emergência e no número de internações e de óbitos. Mais do que descompensar doenças pré-existentes, exposições crônicas têm ajudado a aumentar o número de casos novos de asma, de DPOC e de câncer de pulmão, tanto em áreas urbanas quanto em áreas rurais, fazendo com que os poluentes atmosféricos rivalizem com a fumaça do tabaco pelo papel de principal fator de risco para estas doenças. Na rotina de clínicos e pneumologistas, esperamos contribuir para consolidar a importância da investigação sobre a exposição aos poluentes do ar e o reconhecimento de que esse fator de risco merece ser levado em conta na adoção da melhor terapêutica para o controle das descompensações agudas das doenças respiratórias e para a sua manutenção entre as crises.