21 resultados para PHARMACEUTICAL INTEREST
Resumo:
The aim of this study was to develop a formulation, containing the propolis standardized extract (EPP-AF (R)), which can assist in the healing of skin lesions. To achieve this objective the antimicrobial activity and chemical composition of the propolis extract was determined. The final product was subjected to in vitro and in vivo pre-clinical evaluation. The broth macrodi-lution method was used to determine the antimicrobial activity of the extracts and formulations against the microorganisms most commonly found in burns, Pseudomonas aeruginosa, Klebsiella pneumoniae, Escherichia coli, Staphylococcus aureus and Staphylococcus epidermidis. Wistar rats with puncture wounded skin were used to evaluate the wound healing properties of propolis. The results of chemical and biological characterization demonstrated the batch-to-batch reproducibility of the standardized extract which is an unprecedented result. The antimicrobial and wound healing activity of the pharmaceutical studied showed the best results when samples contain 3.6% propolis, suggesting that this is the most promising composition.
Resumo:
Pharmaceutical equivalence is an important step towards the confirmation of similarity and Interchangeability among pharmaceutical products, particularly regarding those that win not be tested for bioequivalence. The aim of this paper is to compare traditional difference testing to two one-side equivalence tests in the assessment of pharmaceutical equivalence, by means of equivalence studies between similar, generic and reference products of acyclovir cream, atropine sulfate injection, meropenem for injection, and metronidazole injection. All tests were performed in accordance with the Brazilian Pharmacopeia or the United States Pharmacopeia. All four possible combinations of results arise in these comparisons of difference testing and equivalence testing. Most of the former did not show significant difference, whereas the latter presented similarity. We concluded that equivalence testing is more appropriate than difference testing, what can make it a useful tool to assess pharmaceutical equivalence in products that will not be tested for bioequivalence.
Resumo:
Active pharmaceutical ingredients have very strict quality requirements; minor changes in the physical and chemical properties of pharmaceuticals can adversely affect the dissolution rate and therefore the bioavailability of a given drug. Accordingly, the aim of the present study was to investigate the effect of spray drying on the physical and in vitro dissolution properties of four different active pharmaceutical ingredients, namely carbamazepine, indomethacin, piroxicam, and nifedipine. Each drug was dispersed in a solution of ethanol and water (70:30) and subjected to single-step spray drying using similar operational conditions. A complete characterization of the spray-dried drugs was performed via differential scanning calorimetry (DSC), scanning electron microscopy (SEM), X-ray powder diffraction (XRPD), particle size distribution analysis, solubility analysis, and an in vitro dissolution study. The results from the thermal analysis and X-ray diffraction showed that, except for carbamazepine, no chemical modifications occurred as a result of spray drying. Moreover, the particle size distribution of all the spray-dried drugs significantly decreased. In addition, SEM images showed that most of the particles had an irregular shape. There was no significant improvement in the solubility of the spray-dried drugs compared with the unprocessed compounds; however, in general, the dissolution rates of the spray-dried drugs showed a remarkable improvement over their non-spray-dried counterparts. Therefore, the results from this study demonstrate that a single spray-drying step may lead to changes in the physical properties and dissolution characteristics of drugs and thus improve their therapeutic action.
Resumo:
Abstract Background Depressive symptoms and chronic disease have adverse effects on patients' health-related quality of life (H-RQOL). However, little is known about this effect on H-RQOL when only the two core depressive symptoms - loss of interest and depressed mood - are considered. The objective of this study is to investigate H-RQOL in the presence of loss of interest and depressed mood at a general medical outpatient unit. Methods We evaluated 553 patients at their first attendance at a general medical outpatient unit of a teaching hospital. H-RQOL was assessed with the Medical Outcomes Study 36-item Short-Form Health Survey (SF-36). Depressed mood and loss of interest were assessed by the Primary Care Evaluation of Mental Disorders (PRIME-MD)-Patient Questionnaire. A physician performed the diagnosis of chronic diseases by clinical judgment and classified them in 13 possible pre-defined categories. We used multiple linear regression to investigate associations between each domain of H-RQOL and our two core depression symptoms. The presence of chronic diseases and demographic variables were included in the models as covariates. Results Among the 553 patients, 70.5% were women with a mean age of 41.0 years (range 18-85, SD ± 15.4). Loss of interest was reported by 54.6%, and depressed mood by 59.7% of the patients. At least one chronic disease was diagnosed in 59.5% of patients; cardiovascular disease was the most prevalent, affecting 20.6% of our patients. Loss of interest and depressed mood was significantly associated with decreased scores in all domains of H-RQOL after adjustment for possible confounders. The presence of any chronic disease was associated with a decrease in the domain of vitality. The analysis of each individual chronic disease category revealed that no category was associated with a decrease in more than one domain of H-RQOL. Conclusion Loss of interest and depressed mood were associated with significant decreases in H-RQOL. We recommend these simple tests for screening in general practice.
Resumo:
Neste trabalho é proposto um fotômetro baseado em LED (diodo emissor de luz) para fotometria em fase sólida. O fotômetro foi desenvolvido para permitir o acoplamento da fonte de radiação (LED) e do fotodetector direto na cela de fluxo, tendo um caminho óptico de 4 mm. A cela de fluxo foi preenchida com material sólido (C18), o qual foi utilizado para imobilizar o reagente cromogênico 1-(2-tiazolilazo)-2-naftol (TAN). A exatidão foi avaliada empregando dados obtidos através da técnica ICP OES (espectrometria de emissão por plasma indutivamente acoplado). Aplicando-se o teste-t pareado não foi observada diferença significativa em nível de confiança de 95%. Outros parâmetros importantes encontrados foram faixa de resposta linear de 0,05 a 0,85 mg L-1 Zn, limite de detecção de 9 µg L-1 Zn (n = 3), desvio padrão de 1,4 % (n = 10), frequência de amostragem de 36 determinações por h, e uma geração de efluente e consumo de reagente de 1,7 mL e 0,03 µg por determinação, respectivamente.