21 resultados para On-line solid phase extraction (SPE)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work, a LED (light emitting diode) based photometer for solid phase photometry is described. The photometer was designed to permit direct coupling of a light source (LED) and a photodiode to a flow cell with an optical pathlength of 4 mm. The flow cell was filled with adsorbing solid phase material (C-18), which was used to immobilize the chromogenic reagent 1-(2-thiazolylazo)-2-naphthol (TAN). Aiming to allow accuracy assessment, samples were also analyzed employing ICP OES (inductively coupled plasma optical emission spectrometry) methodology. Applying the paired t-test at the 95% confidence level, no significant difference was observed. Other useful features were also achieved: linear response ranging from 0.05 to 0.85 mg L-1 Zn, limit of detection of 9 mu g L-1 Zn (3 sigma criterion), standard deviation of 1.4% (n = 10), sampling throughput of 36 determinations per h, and a waste generation and reagent consumption of 1.7 mL and of 0.03 mu g per determination, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The designation of biodiesel as an environmental-friendly alternative to diesel oil has improved its commercialization and use. However, most biodiesel environmental safety studies refer to air pollution and so far there have been very few literature data about its impacts upon other biotic systems, e.g. water, and exposed organisms. Spill simulations in water were carried out with neat diesel and biodiesel and their blends aiming at assessing their genotoxic potentials should there be contaminations of water systems. The water soluble fractions (WSF) from the spill simulations were submitted to solid phase extraction with C-18 cartridge and the extracts obtained were evaluated carrying out genotoxic and mutagenic bioassays [the Salmonella assay and the in vitro MicroFlow (R) kit (Litron) assay]. Mutagenic and genotoxic effects were observed, respectively, in the Salmonella/microsome preincubation assay and the in vitro MN test carried out with the biodiesel WSF. This interesting result may be related to the presence of pollutants in biodiesel derived from the raw material source used in its production chain. The data showed that care while using biodiesel should be taken to avoid harmful effects on living organisms in cases of water pollution. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work has been supported by Brazilian agencies FAPESP, CNPq, CAPES and grants MICINN BFU200908473 and TIN 201019607, SpanishBrazilian Cooperation PHB20070008 and 7ª Convocatoria De PROYECTOS de COOPERACION INTERUNIVERSITARIAUAMSANTANDER con America Latina

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O trabalho indica alguns sites a serem considerados como alternativa para acesso gratuito a livros on-line disponíveis na Internet e destinados à área médica.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, a procedure for the on-line process control of variables is proposed. This procedure consists of inspecting the m-th item from every m produced items and deciding, at each inspection, whether the process is out-of-control. Two sets of limits, warning (µ0 ± W) and control (µ0 ± C), are used. If the value of the monitored statistic falls beyond the control limits or if a sequence of h observations falls between the warning limits and the control limits, the production is stopped for adjustment; otherwise, production goes on. The properties of an ergodic Markov chain are used to obtain an expression for the average cost per item. The parameters (the sampling interval m, the widths of the warning, the control limits W and C(W < C), and the sequence length (h) are optimized by minimizing the cost function. A numerical example illustrates the proposed procedure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Neste trabalho é proposto um fotômetro baseado em LED (diodo emissor de luz) para fotometria em fase sólida. O fotômetro foi desenvolvido para permitir o acoplamento da fonte de radiação (LED) e do fotodetector direto na cela de fluxo, tendo um caminho óptico de 4 mm. A cela de fluxo foi preenchida com material sólido (C18), o qual foi utilizado para imobilizar o reagente cromogênico 1-(2-tiazolilazo)-2-naftol (TAN). A exatidão foi avaliada empregando dados obtidos através da técnica ICP OES (espectrometria de emissão por plasma indutivamente acoplado). Aplicando-se o teste-t pareado não foi observada diferença significativa em nível de confiança de 95%. Outros parâmetros importantes encontrados foram faixa de resposta linear de 0,05 a 0,85 mg L-1 Zn, limite de detecção de 9 µg L-1 Zn (n = 3), desvio padrão de 1,4 % (n = 10), frequência de amostragem de 36 determinações por h, e uma geração de efluente e consumo de reagente de 1,7 mL e 0,03 µg por determinação, respectivamente.