27 resultados para Mustafa <Kara>Mustafa <Kara>
Resumo:
Patient, 75 years-old, with free wall rupture of the right ventricle, corrected with prolene 3.0 points anchored in bovine pericardium patch, promoting the closure of the rupture. The patient was discharged on the 59th day after surgery in good clinical ans laboratorial conditions.
Resumo:
Objective: To assess the waiting time for eye care identifying the number of patients with each complaint; to investigate how the waiting time may worsen the patient's condition; to check the screening of urgent cases for effectiveness; and to devise means of increasing the medical-surgical care capacity. Methods: A retrospective descriptive survey was conducted using data obtained on 12 occasions during collaborative team visits to provide eyecare services. These initiatives were designed to decrease the waiting time and to treat urgent cases that occurred on each occasion; eyecare services were provided every Saturday, in the period from June to August 2006, in 16 cities of the region covered by Conderg (Consortium for the Development of the Sao Joao da Boa Vista Administrative Region). Results: Referrals used 1,743 (87.1%) of the 2,000 places available. The most frequent diagnoses were refractive errors, with 683 cases, corresponding to 39.1% of the total, followed by cataracts, with 296 cases, corresponding to 20.9%. Of the 238 surgeries indicated, 54.6% were phakectomies. Thirty-five (2.0%) cases were considered urgent. Conclusion: The most common diagnoses made during the team visits to manage the excess demand for eyecare were refractive errors and cataracts, which, together, accounted for the majority of the cases. The Divinolandia Hospital has the necessary human and material resources to meet the demand left unattended by the local SUS network. Immediate referral of urgent cases by the primary units' screeners proved effective.
Resumo:
We present STAR measurements of azimuthal anisotropy by means of the two- and four-particle cumulants nu(2) (nu(2){2} and nu(2){4}) for Au + Au and Cu + Cu collisions at center-of-mass energies root S-NN = 62.4 and 200 GeV. The difference between nu(2){2}(2) and nu(2){4}(2) is related to nu(2) fluctuations (sigma(nu 2)) and nonflow (delta(2)). We present an upper limit to sigma(nu 2)/nu 2. Following the assumption that eccentricity fluctuations sigma(epsilon) dominate nu(2) fluctuations nu(2)/sigma nu(2) approximate to epsilon/sigma epsilon we deduce the nonflow implied for several models of eccentricity fluctuations that would be required for consistency with nu(2){2} and nu(2){4}. We also present results on the ratio of nu(2) to eccentricity.
Resumo:
STAR's measurements of directed flow (v(1)) around midrapidity for pi(+/-), K-+/-, K-S(0), p, and (p) over bar in Au + Au collisions at root s(NN) = 200 GeV are presented. A negative v(1) (y) slope is observed for most of produced particles (pi(+/-), K-+/-, K-S(0), p, and (p) over bar). In 5%-30% central collisions, a sizable difference is present between the v(1)(y) slope of protons and antiprotons, with the former being consistent with zero within errors. The v(1) excitation function is presented. Comparisons to model calculations (RQMD, UrQMD, AMPT, QGSM with parton recombination, and a hydrodynamics model with a tilted source) are made. For those models which have calculations of v(1) for both pions and protons, none of them can describe v(1()y) forpions and protons simultaneously. The hydrodynamics model with a tilted source as currently implemented cannot explain the centrality dependence of the difference between the v(1)(y) slopes of protons and antiprotons.
Resumo:
Measurements of the differential cross section and the transverse single-spin asymmetry, A(N), vs x(F) for pi(0) and eta mesons are reported for 0.4 < x(F) < 0.75 at an average pseudorapidity of 3.68. A data sample of approximately 6.3 pb(-1) was analyzed, which was recorded during p(up arrow) + p collisions at root s = 200 GeV by the STAR experiment at RHIC. The average transverse beam polarization was 56%. The cross section for pi(0), including the previously unmeasured region of x(F) > 0.55, is consistent with a perturbative QCD prediction, and the eta/pi(0) cross-section ratio agrees with existing midrapidity measurements. For 0.55 < x(F) < 0.75, the average A(N) for eta is 0.210 +/- 0.056, and that for pi(0) is 0.081 +/- 0.016. The probability that these two asymmetries are equal is similar to 3%.
Resumo:
Menopause is associated with changes in lipid levels resulting in increased risk of atherosclerosis and cardiovascular events. Hormone therapy (HT) and atorvastatin have been used to improve lipid profile in postmenopausal women. Effects of HT, atorvastatin and APOE polymorphisms on serum lipids and APOE and LXRA expression were evaluated in 87 hypercholesterolemic postmenopausal women, randomly selected for treatment with atorvastatin (AT, n=17), estrogen or estrogen plus progestagen (HT, n=34) and estrogen or estrogen plus progestagen associated with atorvastatin (HT+AT, n=36). RNA was extracted from peripheral blood mononuclear cells (PBMC) and mRNA expression was measured by TaqMan (R) PCR. APOE epsilon 2/epsilon 3/epsilon 4 genotyping was performed using PCR-RFLP. Total cholesterol (TC). LDL-c and apoB were reduced after each treatment (p<0.001). Triglycerides, VLDL-c and apoAl were reduced only after atorvastatin (p<0.05), whereas triglycerides and VLDL-c were increased after HT (p=0.01). HT women had lower reduction on TC, LDL-c and apoB than AT and HT+AT groups (p<0.05). APOE mRNA expression was reduced after atorvastatin treatment (p=0.03). Although LXRA gene expression was not modified by atorvastatin, it was correlated with APOE mRNA before and after treatments. Basal APOE mRNA expression was not influenced by gene polymorphisms, however the reduction on APOE expression was more pronounced in epsilon 3 epsilon 3 than in epsilon 3 epsilon 4 carriers. Atorvastatin down-regulates APOE mRNA expression and it is modified by APOE genotypes in PBMC from postmenopausal women. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
PURPOSE: To investigate the possible effect of aspherical or yellow tinted intraocular lens (IOL) on contrast sensitivity and blue-on-yellow perimetry. METHODS: This prospective randomized bilateral double-masked clinical study included 52 patients with visually significant bilateral cataracts divided in two groups; 25 patients (50 eyes) received aspherical intraocular lens in one eye and spherical intraocular lens in the fellow eye; and 27 patients (54 eyes) received ultraviolet and blue light filter (yellow tinted) IOL implantation in one eye and acrylic ultraviolet filter IOL in the fellow eye. The primary outcome measures were contrast sensitivity and blue-on-yellow perimetry values (mean deviation [MD] and pattern standard deviation [PSD]) investigated two years after surgery. The results were compared intra-individually. RESULTS: There was a statistically significant between-group (aspherical and spherical intraocular lens) difference in contrast sensitivity under photopic conditions at 12 cycles per degree and under mesopic conditions at all spatial frequencies. There were no between-group significant differences (yellow tinted and clear intraocular lens) under photopic or mesopic conditions. There was no statistically significant difference between all intraocular lens in MD or PSD. CONCLUSION: Contrast sensitivity was better under mesopic conditions with aspherical intraocular lens. Blue-on-yellow perimetry did not appear to be affected by aspherical or yellow tinted intraocular lens. Further studies with a larger sample should be carried out to confirm or not that hypotheses.
Resumo:
OBJETIVO: Analisar a incidência e causas de cancelamento de cirurgias de catarata em um hospital público de referência. MÉTODOS: Trata-se de um estudo retrospectivo em que foram analisados o número de cancelamentos de facectomias durante o ano de 2009. Foram analisados sexo, idade, tipo de procedimento suspenso (facoemulsificação ou extração extracapsular do cristalino), tipo de anestesia, convênio (Sistema Único de Saúde ou convênio/particular) e motivo de suspensão da cirurgia (causas clínicas, institucionais ou pessoais). RESULTADOS: Foram agendadas no período 2.965 cirurgias de catarata, havendo 650 cancelamentos (21,92%). Dentre as principais razões para a suspensão do procedimento destacaram-se as causas clínicas (86,90%). Os meses de inverno apresentaram os maiores índices de suspensão de cirurgias de catarata. CONCLUSÃO: A taxa de cancelamento de cirurgia de catarata em serviços públicos parece ser a mesma que há 10 anos. A principal causa de suspensão deve-se por condições clínicas (hipertensão, diabetes, falta de exames, etc.).
Resumo:
OBJETIVO: Comparar custos da cirurgia de catarata em larga escala para um hospital público, para o governo e para a sociedade, pelas técnicas de facoemulsificação (FACO) e extração extracapsular (EECP). MÉTODOS: Foi realizada revisão baseada principalmente em diversos estudos clínicos realizados entre 2002 e 2010, no Centro Cirúrgico Ambulatorial do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo. RESULTADOS: Os gastos estimados com os insumos utilizados para as cirurgias foram de R$ 468,92 no grupo FACO e R$ 259,96 no grupo EECP. As despesas hospitalares com o acompanhamento pós-operatório foram em média de R$ 16,40 (42%) menores no grupo FACO. Com relação ao gasto estimado para a Previdência Social, o grupo EECP custou em média, US$ 44,58 por paciente a mais que o grupo FACO. CONCLUSÃO: O incentivo e o investimento governamental para a realização da FACO no SUS são socialmente justificados, deve-se considerar também a economia dos pacientes e do sistema empresarial, bem como as vantagens clínicas para os pacientes e vantagens econômicas para os hospitais.
Resumo:
OBJECTIVE: To assess the waiting time for eye care identifying the number of patients with each complaint; to investigate how the waiting time may worsen the patient's condition; to check the screening of urgent cases for effectiveness; and to devise means of increasing the medical-surgical care capacity. METHODS: A retrospective descriptive survey was conducted using data obtained on 12 occasions during collaborative team visits to provide eyecare services. These initiatives were designed to decrease the waiting time and to treat urgent cases that occurred on each occasion; eyecare services were provided every Saturday, in the period from June to August 2006, in 16 cities of the region covered by Conderg (Consortium for the Development of the São João da Boa Vista Administrative Region). RESULTS: Referrals used 1,743 (87.1%) of the 2,000 places available. The most frequent diagnoses were refractive errors, with 683 cases, corresponding to 39.1% of the total, followed by cataracts, with 296 cases, corresponding to 20.9%. Of the 238 surgeries indicated, 54.6% were phakectomies. Thirty-five (2.0%) cases were considered urgent. CONCLUSION: The most common diagnoses made during the team visits to manage the excess demand for eyecare were refractive errors and cataracts, which, together, accounted for the majority of the cases. The Divinolândia Hospital has the necessary human and material resources to meet the demand left unattended by the local SUS network. Immediate referral of urgent cases by the primary units' screeners proved effective.
Resumo:
OBJECTIVE: This study sought to compare the effects and outcomes of two ophthalmic viscosurgical devices, 1.6% hyaluronic acid/4.0% chondroitin sulfate and 2.0% hydroxypropylmethylcellulose, during phacoemulsification. METHODS: This prospective, randomized clinical trial comprised 78 eyes (39 patients) that received phacoemulsification performed by the same surgeon using a standardized technique. Patients were randomly assigned to receive either 1.6% hyaluronic acid/4.0% chondroitin sulfate or 2.0% hydroxypropylmethylcellulose on the first eye. The other eye was treated later and received the other viscoelastic agent. Preoperative and postoperative examinations (5, 24 and 48 hours; 7 and 14 days; 3 and 6 months) included measurements of the total volume of the ophthalmic viscosurgical device, ultrasound and washout times to completely remove the ophthalmic viscosurgical device, intraocular pressure, central corneal thickness and best-corrected visual acuity. The corneal endothelial cell count was measured at baseline and at six months postoperatively. ClinicalTrials.gov: NCT01387620. RESULTS: There were no statistically significant differences between groups in terms of cataract density or ultrasound time. However, it took longer to remove 2.0% hydroxypropylmethylcellulose than 1.6% hyaluronic acid/ 4.0% chondroitin sulfate, and the amount of viscoelastic material used was greater in the 2.0% hydroxypropylmethylcellulose group. In addition, the best-corrected visual acuity was significantly better in the hyaluronic acid/ chondroitin sulfate group, but this preferable outcome was only observed at 24 hours after the operation. There were no statistically significant differences between the two ophthalmic viscosurgical devices regarding the central corneal thickness or intraocular pressure measurements at any point in time. The corneal endothelial cell count was significantly higher in the hyaluronic acid/chondroitin sulfate group. CONCLUSION: The ophthalmic viscosurgical device consisting of 1.6% hyaluronic acid/4.0% chondroitin sulfate was more efficient during phacoemulsification and was easier to remove after IOL implantation than 2.0% hydroxypropylmethylcellulose. In addition, the corneal endothelial cell count was significantly higher following the use of hyaluronic acid/chondroitin sulfate than with hydroxypropylmethylcellulose, which promoted an improved level of corneal endothelium protection.