20 resultados para High stability


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The complexity of power systems has increased in recent years due to the operation of existing transmission lines closer to their limits, using flexible AC transmission system (FACTS) devices, and also due to the increased penetration of new types of generators that have more intermittent characteristics and lower inertial response, such as wind generators. This changing nature of a power system has considerable effect on its dynamic behaviors resulting in power swings, dynamic interactions between different power system devices, and less synchronized coupling. This paper presents some analyses of this changing nature of power systems and their dynamic behaviors to identify critical issues that limit the large-scale integration of wind generators and FACTS devices. In addition, this paper addresses some general concerns toward high compensations in different grid topologies. The studies in this paper are conducted on the New England and New York power system model under both small and large disturbances. From the analyses, it can be concluded that high compensation can reduce the security limits under certain operating conditions, and the modes related to operating slip and shaft stiffness are critical as they may limit the large-scale integration of wind generation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A method for the simultaneous quantification of lycopene, β-carotene, retinol and α-tocopherol by high-performance liquid chromatography (HPLC) with Vis/fluorescence detection with isocratic elution was optimized and validated. The method consists of a rapid and simple liquid-liquid extraction procedure and a posterior quantification of extracted supernatants by HPLC. Aliquots of plasma were stored at -20°C for three months for stability study. The methodology was applied to samples from painters and individuals not exposed to paints (n = 75). The assay was linear for all vitamins (r > 0.99). Intra- and inter-run precisions were obtained with coefficient of variation smaller than 5%. The accuracies ranged from 0.29 to -5.80% and recoveries between 92.73 and 101.97%. Plasma samples and extracted supernatants were stable for 60 days at -20°C. A significant decrease of lycopene, β-carotene and retinol concentrations in plasma from exposed individuals compared to non-exposed individuals (p < 0.05) was observed. The method is simple, reproducible, precise, accurate and sensitive, and can be routinely utilized in clinical laboratories.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ceftazidime is a broad spectrum antibiotic administered mainly by the parenteral route, and it is especially effective against Pseudomonas aeruginosa. The period of time in which serum levels exceed the Minimum Inhibitory Concentration (MIC) is an important pharmacodynamic parameter for its efficacy. One of the forms to extend this period is to administer the antibiotic by continuous infusion, after prior dilution in a Parenteral Solution (PS). The present work assessed the stability of ceftazidime in 5% glucose PS for 24 hours, combined or not with aminophylline, through High Performance Liquid Chromatography (HPLC). The physicochemical evaluation was accompanied by in vitro antimicrobial activity compared MIC test in the 24-hour period. Escherichia coli and Pseudomonas aeruginosa were the microorganisms chosen for the MIC comparison. The HPLC analysis confirmed ceftazidime and aminophylline individual stability on PS, while the MIC values were slightly higher than the mean described in the literature. When both drugs were associated in the same PS, the ceftazidime concentration by HPLC decreased 25% after 24 hours. Not only did the MIC values show high loss of antibiotic activity within the same period, but also altered MIC values immediately after the preparation, which was not detected by HPLC. Our results indicate that this drug combination is not compatible, even if used right away, and that PS might not be the best vehicle for ceftazidime, emphasizing the importance of the MIC evaluation for drug interactions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Binary stars are frequent in the universe, with about 50% of the known main sequence stars being located at a multiple star system (Abt, 1979). Even though, they are universally thought as second rate sites for the location of exo-planets and the habitable zone, due to the difficulties of detection and high perturbation that could prevent planet formation and long term stability. In this work we show that planets in binary star systems can have regular orbits and remain on the habitable zone. We introduce a stability criterium based on the solution of the restricted three body problem and apply it to describe the short period planar and three-dimentional stability zones of S-type orbits around each star of the Alpha Centauri system. We develop as well a semi-analytical secular model to study the long term dynamics of fictional planets in the habitable zone of those stars and we verify that planets on the habitable zone would be in regular orbits with any eccentricity and with inclination to the binary orbital plane up until 35 degrees. We show as well that the short period oscillations on the semi-major axis is 100 times greater than the Earth's, but at all the time the planet would still be found inside the Habitable zone.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ceftazidime is a broad spectrum antibiotic administered mainly by the parenteral route, and it is especially effective against Pseudomonas aeruginosa. The period of time in which serum levels exceed the Minimum Inhibitory Concentration (MIC) is an important pharmacodynamic parameter for its efficacy. One of the forms to extend this period is to administer the antibiotic by continuous infusion, after prior dilution in a Parenteral Solution (PS). The present work assessed the stability of ceftazidime in 5% glucose PS for 24 hours, combined or not with aminophylline, through High Performance Liquid Chromatography (HPLC). The physicochemical evaluation was accompanied by in vitro antimicrobial activity compared MIC test in the 24-hour period. Escherichia coli and Pseudomonas aeruginosa were the microorganisms chosen for the MIC comparison. The HPLC analysis confirmed ceftazidime and aminophylline individual stability on PS, while the MIC values were slightly higher than the mean described in the literature. When both drugs were associated in the same PS, the ceftazidime concentration by HPLC decreased 25% after 24 hours. Not only did the MIC values show high loss of antibiotic activity within the same period, but also altered MIC values immediately after the preparation, which was not detected by HPLC. Our results indicate that this drug combination is not compatible, even if used right away, and that PS might not be the best vehicle for ceftazidime, emphasizing the importance of the MIC evaluation for drug interactions.