21 resultados para Fibular osteocutaneous flap
Resumo:
Analytical and numerical analyses of the nonlinear response of a three-degree-of-freedom nonlinear aeroelastic system are performed. Particularly, the effects of concentrated structural nonlinearities on the different motions are determined. The concentrated nonlinearities are introduced in the pitch, plunge, and flap springs by adding cubic stiffness in each of them. Quasi-steady approximation and the Duhamel formulation are used to model the aerodynamic loads. Using the quasi-steady approach, we derive the normal form of the Hopf bifurcation associated with the system's instability. Using the nonlinear form, three configurations including supercritical and subcritical aeroelastic systems are defined and analyzed numerically. The characteristics of these different configurations in terms of stability and motions are evaluated. The usefulness of the two aerodynamic formulations in the prediction of the different motions beyond the bifurcation is discussed.
Resumo:
Background: This study has evaluated the effect of antimicrobial photodynamic therapy (aPDT) used in conjunction with non-surgical and surgical periodontal treatment (PT) in modulating gene expression during periodontal wound healing. Methods: Fifteen patients with chronic periodontitis, presenting bilaterally lower molars with class III furcation lesions and scheduled for extraction, were selected. In initial therapy, scaling and root planing (SRP) was performed in the Control Group (CG), while SRP + aPDT were performed in the Test Group (TG). 45 days later, flap surgery plus SRP, and flap surgery plus SRP + aPDT were performed in the CG and TG, respectively. At 21 days post-surgery, the newly formed granulation tissue was collected, and Real-time PCR evaluated the expression of the genes: tumor necrosis factor-?, interleukin-1?, interleukin-4, interleukin-10, matrix metalloproteinase-2 (MMP-2), tissue inhibitor of metalloproteinase-2 (TIMP-2), osteoprotegerin (OPG), receptor activator of nuclear factor- ?B ligand (RANKL), type I collagen, alkaline phosphatase, osteopontin, osteocalcin, and bone sialoprotein. Results: There were statistically significant differences between the groups in relation to mRNA levels for MMP-2 (TG = 3.26 ± 0.89; CG = 4.23 ± 0.97; p = 0.01), TIMP-2/MMP-2 ratio (TG = 0.91 ± 0.34; CG = 0.73 ± 0.32; p = 0.04), OPG (TG = 0.84 ± 0.45; CG = 0.30 ± 0.26; p = 0.001), and OPG/RANKL ratio (TG = 0.60 ± 0.86; CG = 0.23 ± 0.16; p = 0.04), favoring the TG. Conclusion: The present data suggest that the aPDT associated to nonsurgical and surgical periodontal therapy may modulate the extracellular matrix and bone remodeling by up regulating the TIMP- 2/MMP-2 and OPG/RANKL mRNA ratio, but the clinical relevance needs to be evaluated in further studies.
Resumo:
Infrapopliteal mycotic aneurysm resulting from endocarditis is rare, with only a few reported cases. We describe the case of a 28-year-old male patient who was suffering with pain and edema in the right leg. The ultrasound revealed an aneurysm of the right tibioperoneal trunk and a deep vein thrombosis (DVT). The patient was admitted and developed acute congestive heart failure, being diagnosed with possible endocarditis. A pseudo-aneurysm was revealed by arteriography. Aggressive antibiotic treatment was initiated, and open surgery confirmed a mycotic pseudo-aneurysm of the tibioperoneal trunk. To our knowledge, this is the 8th case reported of an infected aneurysm in this particular location.
Resumo:
Smokers have small root coverage which is associated with bad vascularity of periodontal tissues. This study evaluated a technique that can increase the blood supply to the periodontal tissues compared with a traditional technique. Twenty heavy smokers (10 males and 10 females) with two bilateral Miller class I gingival recessions received coronally positioned flaps in one side (Control group)and extended flap technique in the other side (Test group). Clinical measurements (probing pocket depth, clinical attachment level, bleeding on probing, gingival recession height, gingival recession width, amount of keratinized tissue, and width and height of the papillae adjacent to the recession) were determined at baseline, 3 and 6 months postoperatively. Salivary cotinina samples were taken as an indicator of the nicotine exposure level. No statistically significant differences (p>0.05) were detected for the clinical measurements or smoke exposure. Both techniques promoted low root coverage (Control group: 43.18% and Test group: 44.52%). In conclusion, no difference was found in root coverage between the techniques. Root coverage is possible and uneventful even, if rather low, in heavy smoker patients with low plaque and bleeding indices.
Resumo:
INTRODUÇÃO: A entorse de tornozelo é uma das lesões mais comuns em atletas. Uma forma de avaliar a frouxidão ligamentar pode ser através da medida da amplitude passiva dos movimentos de inversão e eversão do pé para estimar a resistência passiva das estruturas capsuloligamentares do tornozelo, o qual pode ser chamado de torque de resistência passiva. Existem poucos estudos que utilizam a avaliação do torque passivo do tornozelo para avaliar a resistência da cápsula e dos ligamentos. OBJETIVO: O objetivo deste estudo foi comparar o torque passivo dos movimentos de inversão e eversão do pé em atletas com e sem história de entorse de tornozelo. MÉTODO: Participaram do estudo 32 atletas de basquetebol e voleibol feminino (16,06 ± 0,8 anos, 67,63 ± 8,17kg, 177,8 ± 6,47cm). Seus tornozelos foram divididos em dois grupos: grupo controle (29), composto por tornozelos sem sintomas, e grupo entorse de tornozelo, composto por tornozelos que sofreram lesão (29). O torque dos movimentos passivos do tornozelo foi registrado por um dinamômetro isocinético, e a atividade dos músculos fibular longo e tibial anterior foi medida por um eletromiógrafo. As atletas realizaram duas repetições do movimento de inversão e eversão, nas velocidades de 5, 10 e 20°/s e, em seguida, o mesmo protocolo foi repetido apenas para o movimento de inversão máxima do pé. RESULTADOS: O torque de resistência passiva durante os movimentos de inversão e eversão do pé foi menor no grupo com entorse do tornozelo. Este grupo também mostrou menor torque durante o movimento de inversão máxima do pé. Não foram observadas diferenças entre o movimento de inversão e eversão. CONCLUSÕES: A entorse de tornozelo leva a um menor torque de resistência passiva, indicando redução da resistência dos ligamentos colaterais do tornozelo e uma frouxidão articular mecânica.
Resumo:
This paper presents the new active absorption wave basin, named Hydrodynamic Calibrator (HC), constructed at the University of São Paulo (USP), in the Laboratory facilities of the Numerical Offshore Tank (TPN). The square (14 m 14 m) tank is able to generate and absorb waves from 0.5 Hz to 2.0 Hz, by means of 148 active hinged flap wave makers. An independent mechanical system drives each flap by means of a 1HP servo-motor and a ball-screw based transmission system. A customized ultrasonic wave probe is installed in each flap, and is responsible for measuring wave elevation in the flap. A complex automation architecture was implemented, with three Programmable Logic Computers (PLCs), and a low-level software is responsible for all the interlocks and maintenance functions of the tank. Furthermore, all the control algorithms for the generation and absorption are implemented using higher level software (MATLAB /Simulink block diagrams). These algorithms calculate the motions of the wave makers both to generate and absorb the required wave field by taking into account the layout of the flaps and the limits of wave generation. The experimental transfer function that relates the flap amplitude to the wave elevation amplitude is used for the calculation of the motion of each flap. This paper describes the main features of the tank, followed by a detailed presentation of the whole automation system. It includes the measuring devices, signal conditioning, PLC and network architecture, real-time and synchronizing software and motor control loop. Finally, a validation of the whole automation system is presented, by means of the experimental analysis of the transfer function of the waves generated and the calculation of all the delays introduced by the automation system.