22 resultados para Electromagnetic transient


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe the system of massive Weyl fields propagating in a background matter and interacting with an external electromagnetic field. The interaction with an electromagnetic field is due to the presence of anomalous magnetic moments. To canonically quantize this system first we develop the classical field theory treatment of Weyl spinors in frames of the Hamilton formalism which accounts for the external fields. Then, on the basis of the exact solution of the wave equation for a massive Weyl field in a background matter we obtain the effective Hamiltonian for the description of spin-flavor oscillations of Majorana neutrinos in matter and a magnetic field. Finally, we incorporate in our analysis the neutrino self-interaction which is essential when the neutrino density is sufficiently high. We also discuss the applicability of our results for the studies of collective effects in spin-flavor oscillations of supernova neutrinos in a dense matter and a strong magnetic field. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The first measurement of neutron emission in electromagnetic dissociation of Pb-208 nuclei at the LHC is presented. The measurement is performed using the neutron zero degree calorimeters of the ALICE experiment, which detect neutral particles close to beam rapidity. The measured cross sections of single and mutual electromagnetic dissociation of Pb nuclei at root s(NN) = 2.76 TeV with neutron emission are sigma(singleEMD) = 187.4 +/- 0.2(stat)(-11.2)(+13.2) (syst) b and sigma(mutualEMD) = 5. 7 +/- 0.1(stat) +/- 0.4(syst) b, respectively. The experimental results are compared to the predictions from a relativistic electromagnetic dissociation model. DOI: 10.1103/PhysRevLett.109.252302

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background-Patients with acute coronary syndromes and history of stroke or transient ischemic attack (TIA) have an increased rate of recurrent cardiac events and intracranial hemorrhages. Methods and Results-We evaluated treatment effects of ticagrelor versus clopidogrel in patients with acute coronary syndrome with and without a history of prior stroke or TIA in the PLATelet inhibition and patient Outcomes (PLATO) trial. Of the 18 624 randomized patients, 1152 (6.2%) had a history of stroke or TIA. Such patients had higher rates of myocardial infarction (11.5% versus 6.0%), death (10.5% versus 4.9%), stroke (3.4% versus 1.2%), and intracranial bleeding (0.8% versus 0.2%) than patients without prior stroke or TIA. Among patients with a history of stroke or TIA, the reduction of the primary composite outcome and total mortality at 1 year with ticagrelor versus clopidogrel was consistent with the overall trial results: 19.0% versus 20.8% (hazard ratio, 0.87; 95% confidence interval, 0.66-1.13; interaction P=0.84) and 7.9% versus 13.0% (hazard ratio, 0.62; 95% confidence interval, 0.42-0.91). The overall PLATO-defined bleeding rates were similar: 14.6% versus 14.9% (hazard ratio, 0.99; 95% confidence interval, 0.71-1.37), and intracranial bleeding occurred infrequently (4 versus 4 cases, respectively). Conclusions-Patients with acute coronary syndrome with a prior history of ischemic stroke or TIA had higher rates of clinical outcomes than patients without prior stroke or TIA. However, the efficacy and bleeding results of ticagrelor in these high-risk patients were consistent with the overall trial population, with a favorable clinical net benefit and associated impact on mortality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A charged particle is considered in a complex external electromagnetic field. The field is a superposition of an Aharonov-Bohm field and some additional field. Here we describe all additional fields known up to the present time that allow exact solution of the Schrodinger equation in a complex field.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background In ROCKET AF, rivaroxaban was non-inferior to adjusted-dose warfarin in preventing stroke or systemic embolism among patients with atrial fibrillation (AF). We aimed to investigate whether the efficacy and safety of rivaroxaban compared with warfarin is consistent among the subgroups of patients with and without previous stroke or transient ischaemic attack (TIA). Methods In ROCKET AF, patients with AF who were at increased risk of stroke were randomly assigned (1:1) in a double-blind manner to rivaroxaban 20 mg daily or adjusted dose warfarin (international normalised ratio 2-0-3.0). Patients and investigators were masked to treatment allocation. Between Dec 18,2006, and June 17,2009,14 264 patients from 1178 centres in 45 countries were randomly assigned. The primary endpoint was the composite of stroke or non-CNS systemic embolism. In this substudy we assessed the interaction of the treatment effects of rivaroxaban and warfarin among patients with and without previous stroke or TIA. Efficacy analyses were by intention to treat and safety analyses were done in the on-treatment population. ROCKET AF is registered with ClinicalTrials.gov, number NCT00403767. Findings 7468 (52%) patients had a previous stroke (n=4907) or TIA (n=2561) and 6796 (48%) had no previous stroke or TIA. The number of events per 100 person-years for the primary endpoint in patients treated with rivaroxaban compared with warfarin was consistent among patients with previous stroke or TIA (2.79% rivaroxaban vs 2.96% warfarin; hazard ratio [HR] 0-94,95% CI 0.77-1.16) and those without (1.44% vs 1.88%; 0.77, 0.58-1-01; interaction p=0.23). The number of major and non-major clinically relevant bleeding events per 100 person-years in patients treated with rivaroxaban compared with warfarin was consistent among patients with previous stroke or TIA (13.31% rivaroxaban vs 13.87% warfarin; HR 0.96,95% CI 0.87-1-07) and those without (16.69% vs 15.19%; 1.10, 0.99-1.21; interaction p=0.08). Interpretation There was no evidence that the relative efficacy and safety of rivaroxaban compared with warfarin was different between patients who had a previous stroke or TIA and those who had no previous stroke or TIA. These results support the use of rivaroxaban as an alternative to warfarin for prevention of recurrent as well as initial stroke in patients with AF.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Background Hemophilia A is a bleeding disorder caused by deficiency in coagulation factor VIII. Recombinant factor VIII (rFVIII) is an alternative to plasma-derived FVIII for the treatment of hemophilia A. However, commercial manufacturing of rFVIII products is inefficient and costly and is associated to high prices and product shortage, even in economically privileged countries. This situation may be solved by adopting more efficient production methods. Here, we evaluated the potential of transient transfection in producing rFVIII in serum-free suspension HEK 293 cell cultures and investigated the effects of different DNA concentration (0.4, 0.6 and 0.8 μg/106 cells) and repeated transfections done at 34° and 37°C. Results We observed a decrease in cell growth when high DNA concentrations were used, but no significant differences in transfection efficiency and in the biological activity of the rFVIII were noticed. The best condition for rFVIII production was obtained with repeated transfections at 34°C using 0.4 μg DNA/106 cells through which almost 50 IU of active rFVIII was produced six days post-transfection. Conclusion Serum-free suspension transient transfection is thus a viable option for high-yield-rFVIII production. Work is in progress to further optimize the process and validate its scalability.