46 resultados para Cavity implant


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE. The aim of the present study was to evaluate if a smaller morse taper abutment has a negative effect on the fracture resistance of implant-abutment connections under oblique compressive loads compared to a conventional abutment MATERIALS AND METHODS. Twenty morse taper conventional abutments (4.8 mm diameter) and smaller abutments (3.8 mm diameter) were tightened (20 Ncm) to their respective implants (3.5 x 11 mm) and after a 10 minute interval, implant/abutment assemblies were subjected to static compressive test, performed in a universal test machine with 1 mm/min displacement, at 45 degrees inclination. The maximum deformation force was determined. Data were statistically analyzed by student t test. RESULTS. Maximum deformation force of 4.8 mm and 3.8 mm abutments was approximately 95.33 kgf and 95.25 kgf, respectively, but no fractures were noted after mechanical test. Statistical analysis demonstrated that the evaluated abutments were statistically similar (P=.230). CONCLUSION. Abutment measuring 3.8 mm in diameter (reduced) presented mechanical properties similar to 4.8 mm (conventional) abutments, enabling its clinical use as indicated. [J Adv Prosthodont 2012;4:158-61]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate the masticatory efficiency of patients rehabilitated with conventional dentures (CDs) or implant-retained mandibular overdentures. Background: Despite the evident benefits of implants on mastication as assessed by subjective patient-based outcomes, the extent of implant overdenture treatment effect on food comminution is not well established. Materials and methods: A randomised clinical trial was carried out with 29 completely edentulous patients divided into two groups. The first group was rehabilitated with a mandibular overdenture retained by two splinted implants with bar-clip system, while the second group was rehabilitated with a mandibular CD. Both groups also were rehabilitated with maxillary CDs. Masticatory efficiency and patient satisfaction were assessed 3 months after denture insertion. Masticatory efficiency was evaluated through the colorimetric method with the beads as the artificial test-food. Comparisons for masticatory efficiency and patient satisfaction were performed using Student's t-test (alpha = 0.05). Results: No significant statistical difference was found for masticatory efficiency (p = 0.198). Patient overall satisfaction was significantly higher for the mandibular overdenture (p < 0.001). In addition, mandibular overdenture patients were significantly more satisfied with chewing experience (p < 0.05) and retention of the lower denture (p < 0.005). Conclusion: The results of this study suggest that mandibular overdenture significantly improves chewing experience, although limited effect on masticatory efficiency has been observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The puerperium is the period of highest risk for thrombosis during a woman's reproductive life and it is an important time for initiating an effective contraceptive method in order to increase intergestational interval. Thus, the objective of the present study was to evaluated the effects of the etonogestrel (ENG)-releasing contraceptive implant inserted immediately postpartum on maternal hemostasis markers during the first six weeks of delivery. Materials and Methods: Forty healthy women aged 18 to 35 years-old were randomized to receive either the ENG-releasing implant 24-48 h after delivery (implant group; n=20) or nothing (control group) until the sixth postpartum week. Blood samples were collected at 24-48 h and at 6 weeks after delivery, and hemostatic variables, including fibrinogen, coagulation factors, protein C, free protein S, antithrombin, alpha 2-antiplasmin, plasminogen activator inhibitor 1, thrombin-antithrombin complex (TAT), prothrombin fragment (PF)1+2, and D-dimers, as well as normalized activated protein C sensitivity ratio (nAPCsr), thrombin time, activated partial thromboplastin time, and prothrombin time were evaluated. Results: Insertion of the ENG-releasing contraceptive implant did not change the physiological reduction in overall coagulation (TAT and PF1+2) and fibrinolysis (D-dimer) markers, or nAPCsr. Reductions in factors II, VII, X and fibrinogen and increases in factor V were greater in the control than in the implant group. Clotting factors remained within normal limits throughout the study. Conclusion: The ENG-releasing contraceptive implant inserted immediately postpartum did not have negative effects on physiological variations of the hemostatic system during the first 6 weeks postpartum. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE. Adequate passive-fitting of one-piece cast 3-element implant-supported frameworks is hard to achieve. This short communication aims to present an alternative method for section of one-piece cast frameworks and for casting implant-supported frameworks. MATERIALS AND METHODS. Three-unit implant-supported nickel-chromium (Ni-Cr) frameworks were tested for vertical misfit (n = 6). The frameworks were cast as one-piece (Group A) and later transversally sectioned through a diagonal axis (Group B) and compared to frameworks that were cast diagonally separated (Group C). All separated frameworks were laser welded. Only one side of the frameworks was screwed. RESULTS. The results on the tightened side were significantly lower in Group C (6.43 +/- 3.24 mu m) when compared to Groups A (16.50 +/- 7.55 mu m) and B (16.27 +/- 1.71 mu m) (P<.05). On the opposite side, the diagonal section of the one-piece castings for laser welding showed significant improvement in the levels of misfit of the frameworks (Group A, 58.66 +/- 14.30 mu m; Group B, 39.4.8 +/- 12.03 mu m; Group C, 23.13 +/- 8.24 mu m) (P<.05). CONCLUSION. Casting diagonally sectioned frameworks lowers the misfit levels. Lower misfit levels for the frameworks can be achieved by diagonally sectioning one-piece frameworks. [J Adv Prosthodont 2012;4:89-92]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two cases of swallowing of foreign material related to dental implants during dental practice are described. A conservative approach by clinical-radiographic follow-up was performed in both cases; however, one of the patients required colonoscopy under general anesthesia for the removal of the impacted foreign body from the intestinal region. These complications not only have associated economic cost but also carry the risk of malpractice litigation against the professional; thus, the surgeon was responsible for all the costs of hospital and surgery management of this case. Details of the clinical signs, radiographic examinations, type of treatment, and follow-up are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Deutsche Forschungsgemeinschaft [SFB 840]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Male squid produce intricate spermatophores that, when transferred to the female, undergo the spermatophoric reaction, a complex process of evagination that leads to the attachment of the spermatangium, that is, the everted spermatophore containing the sperm mass. While this process is still not completely understood, the medical literature includes several reports of "oral stinging" (i.e., punctured wounds in the human oral cavity) following consumption of raw male squid, which contains undischarged spermatophores able to inflict such wounds. Here, we revisit a recent medical report of oral stinging by Shiraki et al. (Pathol Int 61:749-751, 2011), providing an in-depth reanalysis of their histological biopsies and revealing vital information on the functioning of squid spermatophores. The morphology of the spermatangia attached within the oral cavity is similar to the condition found in spermatangia naturally attached to female squids. The spermatangia were able to superficially puncture the superficial layers of the oral stratified squamous epithelium, and numerous, minute stellate particles from the squid spermatophore were found adhered to the oral epithelium. These findings corroborate previous hypotheses on the functioning of squid spermatophores, namely that spermatophore attachment generally involves tissue scarification, and that stellate particles play a vital role in the attachment process. Moreover, spermatophore attachment is confirmed to be autonomous (i.e., performed by the spermatophore itself) in another squid species (possibly a loliginid), and the results strongly indicate that the attachment mechanism is not dependent upon a specialized epithelium, nor a mate's specific chemical stimulus. From the pathological point of view, the best prophylactic measure at present is the removal of the internal organs of the raw squid prior to its consumption.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To compare the role of transitory latex and sylastic (R) implants in tympanoplasty on the closure of tympanic perforations. METHODS: A randomized double-blind prospective study was conducted on 107 patients with chronic otitis media submitted to underlay tympanoplasty and divided at random into three groups: control with no transitory implant, latex membrane group, and sylastic (R) membrane group. RESULTS: Greater graft vascularization occurred in the latex membrane group (p<0.05). Good biocompatibility was obtained with the use of the latex and silicone implants, with no effect on the occurrence of infection, otorrhea or otorragy. CONCLUSION: The use of a transitory latex implant induced greater graft vascularization, with a biocompatible interaction with the tissue of the human tympanic membrane.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mini-implant insertion requires accurate surgical technique. This study shows an insertion technique using only tooth crown references; its scientific basis is evaluated radiographically. The sample consisted of 213 inter-radicular septa, evaluated in 53 bitewing radiographs. The proximal contour of adjacent tooth crowns was used to define septum width. The midpoint of the septum width was linked to the interdental contact point to determine septum midline. The distances from septum midline to "mesial and distal teeth were measured to evaluate the septum midline centralization degree in two different septum heights. The difference between mesial and distal distances represented the septum midline deviation degree. The mesial and distal distances were compared by t-tests, and the septum midline deviation was correlated with septum height using Pearson's correlation test. The mesial and distal distances were not statistically different in the midpoint of the septum height, but they were different at the apical septum height. There was a moderate correlation (r = 0.45) between septum midline deviation and septum height. The tooth crown references evaluated on interproximal radiographs determine a high centralization degree of the septum midline on which the insertion site could be defined. The greater centralization degree was observed at the coronal septum area.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The benefits of cochlear implants (CI) for communication skills are obtained over the years. There are but a few studies regarding the long-term outcomes in postlingual deaf children who grew up using the electronic device. Aim: To assess the functional results in a group of postlingual children, 10 years after using a CI. Methods: Ten postlingual deaf children, implanted before 18 years of age, participated in this study. We assessed: sentence recognition and speech intelligibility. We documented: device use and function and the patient's academic/occupational status. Study design: series. Results: The mean scores were 73% for sentence recognition in silence and 40% in noise. The average write-down intelligibility score was 92% and the average rating-scale intelligibility score was 4.15. There were no cases of device failure. Regarding educational/vocational status, three subjects graduated from the University. Five quit education after completing high school. Eight subjects had a professional activity. Conclusion: This study showed that cochlear implantation is a safe and reliable procedure. The postlingual profoundly hearing-impaired children after 10 years of CI use developed satisfactory levels regarding speech perception and intelligibility, and completed at least high school and were inserted in the labor market. Clinical Trials Registry: NCT01400178.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to assess in vitro thermal alterations taking place during the Er:YAG laser cavity preparation of primary tooth enamel at different energies and pulse repetition rates. Forty healthy human primary molars were bisected in a mesio-distal direction, thus providing 80 fragments. Two small orifices were made on the dentin surface to which type K thermocouples were attached. The fragments were individually fixed with wax in a cylindrical PlexiglassA (R) abutment and randomly assigned to eight groups, according to the laser parameters (n = 10): G1 -aEuro parts per thousand 250 mJ/ 3 Hz, G2 -aEuro parts per thousand 250 mJ/ 4 Hz, G3 -aEuro parts per thousand 250 mJ/ 6 Hz, G4 -aEuro parts per thousand 250 mJ/10 Hz, G5 -aEuro parts per thousand 250 mJ/ 15 Hz, G6 -aEuro parts per thousand 300 mJ/ 3 Hz, G7 -aEuro parts per thousand 300 mJ/ 4 Hz and G8 -aEuro parts per thousand 300 mJ/ 6 Hz. An area of 4 mm(2) was delimited. Cavities were done (2 mm long x 2 mm wide x 1 mm thick) using non-contact (12 mm) and focused mode. Temperature values were registered from the start of laser irradiation until the end of cavity preparation. Data were analyzed by one-way ANOVA and Tukey test (p a parts per thousand currency signaEuro parts per thousand 0.05). Groups G1, G2, G6, and G7 were statistically similar and furnished the lowest mean values of temperature rise. The set 250 mJ/10 and 15 Hz yielded the highest temperature values. The sets 250 and 300 mJ and 6 Hz provided temperatures with mean values below the acceptable critical value, suggesting that these parameters ablate the primary tooth enamel. Moreover, the temperature elevation was directly related to the increase in the employed pulse repetition rates. In addition, there was no direct correlation between temperature rise and energy density. Therefore, it is important to use a lower pulse frequency, such as 300 mJ and 6 Hz, during cavity preparation in pediatric patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The capuchin monkey is widespread both north and south of the Legal Amazon and in the Brazilian cerrado. Ten clinically healthy capuchin monkeys were submitted to an anatomical and radiographic study of their thoracic cavities. The radiographic evaluation allowed the description of biometric values associated with the cardiac silhouette and thoracic structures. Application of the VHS (vertebral heart size) method showed positive correlation (P<0.05) with depth of the thoracic cavity, as well as between the body length of vertebrae T 3, T 4, T 5 and T 6 and the cardiac length and width. The lung fields showed a diffuse interstitial pattern, more visible in the caudal lung lobes and a bronchial pattern in the middle and cranial lung lobes. The radiographic examination allowed preliminary inferences to be made concerning the syntopy of the thoracic structures and modifiication of the pulmonary patterns and cardiac anatomy for the capuchin monkey.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To report the results of cochlear implantation via the middle fossa approach in 4 patients, discuss the complications, and present a detailed description of the programming specifications in these cases. Study Design: Retrospective case review. Setting: Tertiary-care referral center with a well-established cochlear implant program. Patients: Four patients with bilateral canal wall down mastoid cavities who underwent the middle fossa approach for cochlear implantation. Interventions: Cochlear implantation and subsequent rehabilitation. A middle fossa approach with cochleostomy was successfully performed on the most superficial part of the apical turn in 4 patients. A Nucleus 24 cochlear implant system was used in 3 patients and a MED-EL Sonata Medium device in 1 patient. The single electrode array was inserted through a cochleostomy from the cochlear apex and occupied the apical, middle, and basal turns. Telemetry and intraoperative impedance recordings were performed at the end of surgery. A CT scan of the temporal bones was performed to document electrode insertion for all of the patients. Main Outcome Measures: Complications, hearing thresholds, and speech perception outcomes were evaluated. Results: Neural response telemetry showed present responses in all but 1 patient, who demonstrated facial nerve stimulation during the test. Open-set speech perception varied from 30% to 100%, despite the frequency allocation order of the MAP. Conclusion: Cochlear implantation via the middle cranial fossa is a safe approach, although it is a challenging procedure, even for experienced surgeons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate the role of keratinized mucosa around dental implants, correlating with other clinical parameters related to the success of dental implants. Design: Cross-section. Setting: Institutional tertiary referral hospital. Patients: A total of 202 dental implants fixed in the cleft area of 109 patients with cleft lip and/or palate were evaluated. Interventions: The evaluated clinical parameters were probing depth and gingival and plaque indexes on the buccal surface (three sites). Main Outcome Measures: All clinical parameters were correlated with the width of keratinized mucosa around the implants. Results: The largest probing depths were detected when the width of keratinized mucosa was 2 mm or more, with a statistically significant difference between the means of the probing depth and keratinized mucosa width. Conclusion: Even though the present results suggest that peri-implant health can be observed in areas with keratinized mucosa width under 2 mm provided an adequate oral hygiene control is performed, longitudinal randomized studies are necessary to analyze the relationship between the width of keratinized mucosa and the health of peri-implant tissues.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objetives: Determine the stability of tibial and femoral components of 20 cementless knee arthroplasties with rotating platform. Methods: The 20 patients (20 knees) underwent an analysis of dynamic radiographs with an image amplifier and maneuvers of varus and valgus which were compared to static frontal and lateral radiographs of the knees and analyzed by two experienced surgeons in a double-blind way. Results: We could observe in this study that both methods showed very similar results for the stability of the tibial and femoral components (p<0.001) using the Kappa method for comparison. Conclusion: The tibial component was more unstable in relation to the femoral component in both static and dynamic studies. Level of Evidence IV, Case Series.