27 resultados para Anchorage implants
Resumo:
Cochlear implants are the best treatment for congenital profound deafness. Pediatric candidates to implantation are seen as vulnerable citizens, and the decision of implanting cochlear devices is ultimately in the hands of their parents/guardians. The Brazilian Penal Code dictates that deaf people may enjoy diminished criminal capacity. Many are the bioethical controversies around cochlear implants, as representatives from the deaf community have seen in them a means of decimating their culture and intrinsic values. Objective: This paper aims to discuss, in bioethical terms, the validity of implanting cochlear hearing aids in children by analyzing their vulnerability and the social/cultural implications of the procedure itself, aside from looking into the medical/legal aspects connected to their criminal capacity. Materials and Methods: The topic was searched on databases Medline and Lilacs; ethical analysis was done based on principialist bioethics. Results: Cochlear implants are the best therapeutic option for people with profound deafness and are morally justified. The level of criminal capacity attributed to deaf people requires careful analysis of the subject's degree of understanding and determination when carrying out the acts for which he/she has been charged. Conclusion: Cochlear implants are morally valid. Implantations must be analyzed on an each case basis. ENT physicians bear the ethical responsibility for indicating cochlear implants and must properly inform the child's parents/guardians and get their written consent before performing the procedure.
Resumo:
A myriad of titanium (Ti) surface modifications has been proposed to hasten the osseointegration. In this context, the aim of this study was to perform histomorphometric, cellular, and molecular analyses of the bone tissue grown in close contact with Ti implants treated by anodic spark deposition (ASD-AK). Acid-etched (AE) Ti implants either untreated or submitted to ASD-AK were placed into dog mandibles and retrieved at 3 and 8 weeks. It was noticed that both implants, AE and ASD-AK, were osseointegrated at 3 and 8 weeks. Histomorphometric analysis showed differences between treatments only for bone-to-implant contact, being higher on AE implants. Although not backed by histomorphometric results, gene expression of key bone markers was higher for bone grown in close contact with ASD-AK and for cells harvested from these fragments and cultured until subconfluence. Cell proliferation at days 7 and 10 and alkaline phosphatase activity at day 10 was higher on AE surfaces. No statistical significant difference was noticed for extracellular matrix mineralization at 17 days. Our results have shown that the Ti fixtures treated by ASD-AK allowed in vivo osseointegration and induced higher expression of key markers of osteoblast phenotype, suggesting that this surface treatment could be considered to produce implants for clinical applications. (c) 2012 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 100A:30923098, 2012.
Resumo:
This study compared the dimensions of gingival papillae in anterosuperior areas presenting at natural teeth (teeth sites) or single-tooth implants adjacent to natural teeth (implant-tooth sites) by analyzing determined distances. A total of 45 teeth and 46 implant-tooth sites were carefully selected. Clinical evaluation consisted of visual and quantitative analyses with millimeter grids on radiographs. Implant-tooth sites showed a smaller gingival papilla dimension than tooth sites (P < .01). Both evaluated distances (contact point to bone crest and between the roots of adjacent teeth or implant platform to root of adjacent tooth) in all groups significantly influenced the presence/absence of gingival papillae (P < .01). (Int J Periodontics Restorative Dent 2012;32:93-100.)
Resumo:
Little is known about the benefits of low-level laser therapy (LLLT) on improvement of stability of dental implants. The aim of this randomized clinical study was to assess the LLLT effect on implants stability by means of resonance frequency analysis (RFA). Thirty implants were distributed bilaterally in the posterior mandible of eight patients. At the experimental side, the implants were submitted to LLLT (830 nm, 86 mW, 92.1 J/cm(2), 0.25 J, 3 s/point, at 20 points), and on the control side, the irradiation was simulated (placebo). The first irradiation was performed in the immediate postoperative period, and it was repeated every 48 h in the first 14 days. The initial implant stability quotient (ISQ) of the implants was measured by means of RFA. New ISQ measurements were made after 10 days, 3, 6, 9, and 12 weeks. The initial ISQ values ranged from 65-84, with a mean of 76, undergoing a significant drop in stability from the 10th day to the 6th week in the irradiated group, and presenting a gradual increase from the 6th to the 12th week. The highest ISQ values were observed on the 10th day in the irradiated group, and the lowest in the 6th week in both groups. Under the conditions of this study, no evidence was found of any effect of LLLT on the stability of the implants when measured by RFA. Since high primary stability and good bone quality are of major relevancy for a rigid bone-implant interface, additional LLLT may have little impact macroscopically.
Resumo:
Aim: Primary and secondary stabilities of immediately loaded mandibular implants restored with fixed prostheses (FP) using rigid or semirigid splinting systems were clinically and radiographically evaluated. Methods: Fifteen edentulous patients were rehabilitated using hybrid FP; each had 5 implants placed between the mental foramens. Two groups were randomly divided: group 1-FP with the conventional rigid bar splinting the implants and group 2-semi-rigid cantilever extension system with titanium bars placed in the 2 distal abutment cylinders. Primary stability was evaluated using resonance frequency analysis after installation of the implant abutments. The measurements were made at 3 times: T0, at baseline; T1, 4 months after implant placement; and T2, 8 months after implant placement. Presence of mobility and inflammation in the implant surrounding regions were checked. Stability data were submitted to statistical analysis for comparison between groups (P, 0.05). Results: Implant survival rate for the implants was of 100% in both groups. No significant differences in the mean implant stability quotient values were found for both groups from baseline and after the 8-month follow-up. Conclusion: The immediate loading of the implants was satisfactory, and both splinting conditions (rigid and semi-rigid) can be successfully used for the restoration of edentulous mandibles. (Implant Dent 2012;21:486-490)
Resumo:
Introduction: In recent years, the benefits associated with the use of cochlear implants (CIs), especially with regard to speech perception, have proven to surpass those produced by the use of hearing aids, making CIs a highly efficient resource for patients with severe/profound hearing loss. However, few studies so far have assessed the satisfaction of adult users of CIs. Objective: To analyze the relationship between the level of speech perception and degree of satisfaction of adult users of CI. Method: This was a prospective cross-sectional study conducted in the Audiological Research Center (CPA) of the Hospital of Craniofacial Anomalies, University of São Paulo (HRAC/USP), in Bauru, São Paulo, Brazil. A total of 12 users of CIs with pre-lingual or post-lingual hearing loss participated in this study. The following tools were used in the assessment: a questionnaire, "Satisfaction with Amplification in Daily Life" (SADL), culturally adapted to Brazilian Portuguese, as well as its relationship with the speech perception results; a speech perception test under quiet conditions; and the Hearing in Noise Test (HINT)Brazil under free field conditions. Results: The participants in the study were on the whole satisfied with their devices, and the degree of satisfaction correlated positively with the ability to perceive monosyllabic words under quiet conditions. The satisfaction did not correlate with the level of speech perception in noisy environments. Conclusion: Assessments of satisfaction may help professionals to predict what other factors, in addition to speech perception, may contribute to the satisfaction of CI users in order to reorganize the intervention process to improve the users' quality of life.
Resumo:
Introduction: The aims of this meta-analysis were to quantify and to compare the amounts of distalization and anchorage loss of conventional and skeletal anchorage methods in the correction of Class II malocclusion with intraoral distalizers. Methods: The literature was searched through 5 electronic databases, and inclusion criteria were applied. Articles that presented pretreatment and posttreatment cephalometric values were preferred. Quality assessments of the studies were performed. The averages and standard deviations of molar and premolar effects were extracted from the studies to perform a meta-analysis. Results: After applying the inclusion and exclusion criteria, 40 studies were included in the systematic review. After the quality analysis, 2 articles were classified as high quality, 27 as medium quality, and 11 as low quality. For the meta-analysis, 6 studies were included, and they showed average molar distalization amounts of 3.34 mm with conventional anchorage and 5.10 mm with skeletal anchorage. The meta-analysis of premolar movement showed estimates of combined effects of 2.30 mm (mesialization) in studies with conventional anchorage and 4.01 mm (distalization) in studies with skeletal anchorage. Conclusions: There was scientific evidence that both anchorage systems are effective for distalization; however, with skeletal anchorage, there was no anchorage loss when direct anchorage was used.
Resumo:
The main objective of this paper was to discuss the importance of the reverse planning as guidance to surgical procedures on immediate loading implant-retained prosthesis, presenting a case report. Such design aims to define anchorage orientation after determination of prosthetic design. This is quite important because the possibility of success of cases with this kind of planning may achieve high levels of satisfaction. Another important aspect is the possibility of fast and definitive restoration of patients’ function and aesthetics
Resumo:
Introduction: This retrospective cephalometric study analyzed the influence of intentional ankylosis of deciduous canines in patients with Class III malocclusion and anterior crossbite, in the deciduous and early mixed dentition stages, treated by orthopedic maxillary expansion followed by maxillary protraction. Methods: Lateral cephalograms of 40 patients were used, divided in 2 groups paired for age and gender. The Ankylosis Group was composed of 20 patients (10 boys and 10 girls) treated with induced ankylosis and presenting initial and final mean ages of 7 years 4 months and 8 years 3 months, respectively, with a mean period of maxillary protraction of 11 months. The Control Group comprised 20 patients (10 boys and 10 girls) treated without induced ankylosis, with initial and final mean ages of 7 years 8 months and 8 years 7 months, respectively, with a mean period of maxillary protraction of 11 months. Two-way analysis of variance and covariance analysis were applied to compare the initial and final cephalometric variables and the treatment changes between groups. Results: According to the results, the variables evidencing the significant treatment changes between groups confirmed that the intentional ankylosis enhanced the sagittal response of the apical bases (Pg-NPerp) and increased the facial convexity angles (NAP and ANB). Conclusions: The protocol involving intentional ankylosis of deciduous canines enhanced the sagittal response of the apical bases.
Resumo:
The present study evaluated the interchangeability of prosthetic components for external hexagon implants by measuring the precision of the implant/abutment (I/A) interface with scanning electron microscopy. Ten implants for each of three brands (SIN, Conexão, Neodent) were tested with their respective abutments (milled CoCr collar rotational and non-rotational) and another of an alternative manufacturer (Microplant) in randomly arranged I/A combinations. The degree of interchangeability between the various brands of components was defined using the original abutment interface gap with its respective implant as the benchmark dimension. Accordingly, when the result for a given component placed on an implant was equal to or smaller then that gap measured when the original component of the same brand as the implant was positioned, interchangeability was considered valid. Data were compared with the Kruskal-Wallis test at 5% significance level. Some degree of misfit was observed in all specimens. Generally, the non-rotational component was more accurate than its rotational counterpart. The latter samples ranged from 0.6-16.9 µm, with a 4.6 µm median; and the former from 0.3-12.9 µm, with a 3.4 µm median. Specimens with the abutment and fixture from Conexão had larger microgap than the original set for SIN and Neodent (p<0.05). Even though the latter systems had similar results with their respective components, their interchanged abutments did not reproduce the original accuracy. The results suggest that the alternative brand abutment would have compatibility with all systems while the other brands were not completely interchangeable.
Resumo:
AIM: To explore the biomechanical effects of the different implantation bone levels of Morse taper implants, employing a finite element analysis (FEA). METHODS: Dental implants (TitamaxCM) with 4x13 mm and 4x11 mm, and their respective abutments with 3.5 mm height, simulating a screwed premolar metal-ceramic crown, had their design performed using the software AnsysWorkbench 10.0. They were positioned in bone blocks, covered by 2.5 mm thickness of mucosa. The cortical bone was designed with 1.5 mm thickness and the trabecular bone completed the bone block. Four groups were formed: group 11CBL (11 mm implant length on cortical bone level), group 11TBL (11 mm implant length on trabecular bone level), group 13CBL (13mm implant length on cortical bone level) and group 13TBL (13 mm implant length on trabecular bone level). Oblique 200 N loads were applied. Von Mises equivalent stresses in cortical and trabecular bones were evaluated with the same design program. RESULTS: The results were shown qualitatively and quantitatively by standard scales for each type of bone. By the results obtained, it can be suggested that positioning the implant completely in trabecular bone brings harm with respect to the generated stresses. Its implantation in the cortical bone has advantages with respect to better anchoring and locking, reflecting a better dissipation of the stresses along the implant/bone interfaces. In addition, the search for anchoring the implant in its apical region in cortical bone is of great value to improve stabilization and consequently better stress distribution. CONCLUSIONS: The implant position slightly below the bone in relation to the bone crest brings advantages as the best long-term predictability with respect to the expected neck bone loss.