26 resultados para Speckle tracking liver motion correction contrast-enhanced ultrasound


Relevância:

100.00% 100.00%

Publicador:

Resumo:

There are no studies investigating the effect of the contrast infusion on the sensitivity and specificity of the main Doppler criteria of renal artery stenosis (RAS). Our aim was to evaluate the accuracy of these Doppler criteria prior to and following the intravenous administration of perfluorocarbon exposed sonicated albumin (PESDA) in patients suspected of having RAS. Thirty consecutive hypertensive patients (13 males, mean age of 57 ± 10 years) suspected of having RAS by clinical clues, were submitted to ultrasonography (US) of renal arteries before and after enhancement using continuous infusion of PESDA. All patients underwent angiography, and haemodynamically significant RAS was considered when ≥50%. At angiography, it was detected RAS ≥50% in 18 patients, 5 with bilateral stenosis. After contrast, the examination time was slightly reduced by approximately 20%. In non-enhanced US the sensitivity was better when based on resistance index (82.9%) while the specificity was better when based on renal aortic ratio (89.2%). The predictive positive value was stable for all indexes (74.0%–88.0%) while negative predictive value was low (44%–51%). The specificity and positive predictive value based on renal aortic ratio increased after PESDA injection respectively, from 89 to 97.3% and from 88 to 95%. In hypertensives suspected to have RAS the sensitivity and specificity of Duplex US is dependent of the criterion evaluated. Enhancement with continuous infusion of PESDA improves only the specificity based on renal aortic ratio but do not modify the sensitivity of any index.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The high and increasing prevalence of Dilated Cardiomyopathy (DCM) represents a serious public health issue. Novel technologies have been used aiming to improve diagnosis and the therapeutic approach. In this context, speckle tracking echocardiography (STE) uses natural myocardial markers to analyze the systolic deformation of the left ventricle (LV). Objective: Measure the longitudinal transmural global strain (GS) of the LV through STE in patients with severe DCM, comparing the results with normal individuals and with echocardiographic parameters established for the analysis of LV systolic function, in order to validate the method in this population. Methods: Seventy-one patients with severe DCM (53 +/- 12 years, 72% men) and 20 controls (30 +/- 8 years, 45% men) were studied. The following variables were studied: LV volumes and ejection fraction calculated by two and three-dimensional echocardiography, Doppler parameters, Tissue Doppler Imaging systolic and diastolic LV velocities and GS obtained by STE. Results: Compared with controls, LV volumes were higher in the DCM group; however, LVEF and peak E-wave velocity were lower in the latter. The myocardial performance index was higher in the patient group. Tissue Doppler myocardial velocities (S', e', a') were significantly lower and E/e' ratio was higher in the DCM group. GS was decreased in the DCM group (-5.5% +/- 2.3%) when compared with controls (-14.0% +/- 1.8%). Conclusion: In this study, GS was significantly lower in patients with severe DCM, bringing new perspectives for therapeutic approaches in this specific population. (Arq Bras Cardiol 2012;99(3):834-842)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

FUNDAMENTO: A alta e crescente prevalência de Cardiomiopatia Dilatada (CMD) representa sério problema de saúde pública. Novas tecnologias vêm sendo utilizadas objetivando diagnósticos mais sofisticados, que melhorem a abordagem terapêutica. Nesse cenário, o Speckle Tracking (STE) utiliza marcadores miocárdicos naturais para analisar a deformação sistólica do Ventrículo Esquerdo (VE). OBJETIVO: Mensurar o strain transmural longitudinal global (SG) do VE através do STE em pacientes com CMD grave, comparando os resultados com indivíduos normais e com parâmetros ecocardiográficos consagrados para análise da função sistólica do VE, validando o método nessa população. MÉTODOS: Foram estudados 71 pacientes com CMD grave, (53 ± 12a, 72% homens) e 20 controles (30 ± 8a, 45% homens). Foram obtidos os volumes e a FEVE pela ecocardiografia bi e tridimensional, parâmetros do Doppler, Doppler tecidual e o SG pelo STE. RESULTADOS: Comparados ao grupo controle, os volumes do VE foram maiores no grupo CMD; entretanto, a FEVE e velocidade de pico da onda E foram menores neste último. O índice de performance miocárdica foi maior entre os pacientes. As velocidades do miocárdio pelo Doppler tecidual (S', e', a') foram consideravelmente menores e a relação E/e' foi maior no grupo CMD. O SG apresentou-se diminuído no grupo CMD (-5,5% ± 2,3%), em relação aos controles (-14,0% ± 1,8%). CONCLUSÃO: No presente estudo, o SG foi significativamente menor nos pacientes com CMD grave, abrindo novas perspectivas para abordagens terapêuticas nessa população específica.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: To integrate data from two-dimensional echocardiography (2D ECHO), three-dimensional echocardiography (3D ECHO), and tissue Doppler imaging (TDI) for prediction of left ventricular (LV) reverse remodeling (LVRR) after cardiac resynchronization therapy (CRT). It was also compared the evaluation of cardiac dyssynchrony by TDI and 3D ECHO. Methods: Twenty-four consecutive patients with heart failure, sinus rhythm, QRS = 120 msec, functional class III or IV and LV ejection fraction (LVEF) = 0.35 underwent CRT. 2D ECHO, 3D ECHO with systolic dyssynchrony index (SDI) analysis, and TDI were performed before, 3 and 6 months after CRT. Cardiac dyssynchrony analyses by TDI and SDI were compared with the Pearson's correlation test. Before CRT, a univariate analysis of baseline characteristics was performed for the construction of a logistic regression model to identify the best predictors of LVRR. Results: After 3 months of CRT, there was a moderate correlation between TDI and SDI (r = 0.52). At other time points, there was no strong correlation. Nine of twenty-four (38%) patients presented with LVRR 6 months after CRT. After logistic regression analysis, SDI (SDI > 11%) was the only independent factor in the prediction of LVRR 6 months of CRT (sensitivity = 0.89 and specificity = 0.73). After construction of receiver operator characteristic (ROC) curves, an equation was established to predict LVRR: LVRR =-0.4LVDD (mm) + 0.5LVEF (%) + 1.1SDI (%), with responders presenting values >0 (sensitivity = 0.67 and specificity = 0.87). Conclusions: In this study, there was no strong correlation between TDI and SDI. An equation is proposed for the prediction of LVRR after CRT. Although larger trials are needed to validate these findings, this equation may be useful to candidates for CRT. (Echocardiography 2012;29:678-687)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE To ascertain whether the volume and circumference of the lacrimal sac and nasolacrimal duct as measured by contrast-enhanced computed tomographic dacryocystography (CT-DCG) before and after balloon dacryoplasty could be used to predict clinical success in children with congenital nasolacrimal obstruction. METHODS Nasolacrimal ducts of children aged 2 to 6 years with clinical signs of congenital nasolacrimal duct obstruction undergoing balloon dilation were imaged with contrast-enhanced CT-DCG before and 5 minutes after the procedure. The circumference of the most dilated portion of the lacrimal sac was measured on the axial plane. The volume of contrast within the nasolacrimal duct and sac was also measured before and after the procedure. Clinical success was defined as the disappearance of signs of epiphora. RESULTS A total of 18 nasolacrimal ducts of 13 children were included. The average circumference of the most dilated portion of the lacrimal sac was 1.30 +/- 0.45 cm (range, 0.64-2.50 cm) before the procedure. The average contrast volume was 0.12 +/- 0.08 cm(3) (range, 0.01-0.38 cm(3)) before and 0.07 +/- 0.06 cm(3) (range, 0.01-0.20 cm(3)) after (P = 0.01). Data were analyzed using multivariate logistic regression with a backward variable input model; a decrease in contrast volume before and after dilation (P = 0.04) was associated with clinical success, whereas the larger size of the most dilated portion of the lacrimal sac (P = 0.01) was associated with clinical failure. CONCLUSIONS Contrast-enhanced CT-DCG provides useful information about nasolacrimal anatomy in children with congenital nasolacrimal duct obstruction. The decrease in contrast volume before and after balloon dilation was predictive of success; A larger size of the most dilated portion of the lacrimal sac was associated with clinical failure. (J AAPOS 2012;16:464-467)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Because of their similar visual appearance, differentiation of left ventricular thrombotic material and myocardial wall can be difficult in contrast-enhanced coronary computed tomography (CT) angiography. OBJECTIVE: We identified typical thrombi attenuation of left ventricular thrombi with the use of CT measurement. METHODS: Over a time period of 6 years; we retrospectively identified 31 patients who showed a left ventricular thrombus in CT angiography datasets. Patients underwent routine contrast cardiac CT to investigate coronary artery disease. CT attenuation of each thrombus was assessed in the 4-chamber view. CT densities were also determined in the ascending aorta, left ventricle, and myocardial wall both in the mid-septal and mid-lateral segments. The mean CT attenuation of thrombi and the difference between attenuation in thrombi, left ventricular cavity, and myocardial wall were determined. The ratio of attenuation values in thrombus versus aorta and myocardium versus aorta were also determined. RESULTS: Mean (+/- SD) CT attenuation of all left ventricular thrombi in 31 patients was 43.2 +/- 15.3 HU (range, 25-80 HU). Mean CT densities of septal and lateral myocardial wall were 102.9 +/- 23.1 HU (range, 63-155 HU) and 99.3 +/- 28.7 HU (range, 72-191 HU), respectively, and were thus significantly higher than the CT attenuation of thrombi (P < 0.001). A threshold of 65 HU yielded a sensitivity, specificity, and positive and negative predictive values of 94%, 97%, 94%, and 97%, respectively, to differentiate thrombus from the myocardial wall. The mean ratio between CT attenuation of thrombus and CT attenuation within the ascending aorta was 0.11 +/- 0.05 (range, 0.04-0.23), which was significantly lower compared with the mean ratio between CT attenuation of the myocardial wall and the CT attenuation within the ascending aorta. CONCLUSION: CT attenuation within left ventricular thrombi was significantly lower than myocardial attenuation in CT angiography datasets. Assessment of CT attenuation may contribute to the differentiation of thrombi. (C) 2012 Society of Cardiovascular Computed Tomography. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Early Diagnosis of Miocardial Dysfunction in Patients with Hematological Malignancies Submitted to Chemotherapy. Preliminary Background: Considering the current diagnostic improvements and tl1erapeutic approaches, patients witl 1 cancer can now be healed or keep the disease under control, still, the chemotherapy may cause heart damage, evolving to Congestive Heart Failure. Recognition of those changes increases the chances of control the endpoints; hence, new parameters of cardiac and fluid mechanics analysis have been used to assess the myocardial function, pursuing an earlier diagnosis of the cardiac alterations. This study aimed to detect early cardiac dysfunction consequently to chemotherapy in patients with hematological malignancies (HM). Methods: Patients with leukemia and lymphoma, submitted to chemotherapy, without knowing heart diseases were studied. Healthy volunteers served as the control group. Conventional 2DE parameters of myocardial function were analyzed. The peak global longitudinal, circumferential and radial left ventricular (LV) strain were deternined by 2D and 3D speckle tracking (STE); peak area strain measured by 3D STE and LV torsionn, twisting rate, recoil / recoil rate assessed by 2D STE. The LV vortex formation time (VFT) during the rapid diastolic filling was estimated by the 2D mitral valve (MV) planimetry and Pulsed Doppler LV inflow by: VFT- 4(1-β) / π x α3 x LVEF Where 1- β is the E wave contribution to the LV stroke volume and α3 is a volumetric variable related to the MV area. The statistical level was settled on 5%. Results: See Table. Conclusion: Despite the differences between the two groups concerning the LVESV, LVEF and E´, those parameters still are in the normal range when considering the patients submitted to chemotherapy; thus, in the clinical setting, they are not so noticeable. The 3D GLS was smaller among the patients, oppositely to the 2D GLS, suggesting that the former variable is more accurate to assess tlhe LV systolic function. The VFT is a dimensionless measure of the optimal vortex development inside the LV chamber; reflecting the efficiency of the diastolic filling and, consequently, blood ejection. This index showed to be diminished in patients with HM submitted to chemotherapy, indicating an impairment of the in1pulse and thrust, hence appearing to be a very early marker of diastolic and systolic dysfunction in this group.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Transient visual evoked cortical potentials (VECP) were recorded from the scalp of healthy normal trichromats (n = 12). VECPs were elicited by onset/offset presentation of patterned stimuli of two kinds: isochromatic luminance-modulated, and equiluminant red-green modulated, sine wave gratings. The amplitude and latency of the major onset components of the onset/offset VECP were measured and plotted as a function of the logarithm of pooled cone contrast. The early onset components, achromatic C1 and chromatic N1, increase linearly with log contrast, but N1 has a higher contrast gain than C1. The late onset components, achromatic C2 and chromatic N2, have similar contrast gain, and similar response as a function of contrast level: both increase in the low-to-medium range of contrasts and saturate at high contrast levels. In the range of pooled cone contrast tested, C1 and N1 show similar latencies, whilst C2 shows shorter latencies than N2. We suggest that C1 and N1 are generated by the same visual mechanism with high red-green contrast gain and low luminance contrast gain, whilst C2 and N2 are generated by different visual mechanisms.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

CLN is a frequent histological finding in biopsies after pediatric: LT, and its pathogenesis has not yet been fully clarified and has different causes. Among the vascular causes, VOB is sometimes difficult to diagnose, especially when technical variants such as split-liver, reduced-liver, or living-related LT are utilized. Three liver-transplanted malnourished children (ages 12, 20, and 28 months) developed altered LFTs and post-operative ascites with right pleural effusion (two cases) and jaundice (one case). Doppler ultrasound examinations were normal and liver biopsies showed CLN interpreted as severe ACR. There were no responses to the medical treatment. Additional investigation with CT angiography suggested obstructed hepatic vein drainage, which was confirmed by interventional radiology and angioplasty of the anastomosis between the hepatic vein and the inferior vena cava, with clinical and histological resolution. It is concluded that in malnourished children undergoing LT with technical variations, in which the occurrence of severe ACR is usually less common because of the severity of the patient condition, the finding of CLN should raise the possibility of VOB, so that excessive immunosuppression and its consequences can be avoided.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Intravascular ultrasound (IVUS) phantoms are important to calibrate and evaluate many IVUS imaging processing tasks. However, phantom generation is never the primary focus of related works; hence, it cannot be well covered, and is usually based on more than one platform, which may not be accessible to investigators. Therefore, we present a framework for creating representative IVUS phantoms, for different intraluminal pressures, based on the finite element method and Field II. First, a coronary cross-section model is selected. Second, the coronary regions are identified to apply the properties. Third, the corresponding mesh is generated. Fourth, the intraluminal force is applied and the deformation computed. Finally, the speckle noise is incorporated. The framework was tested taking into account IVUS contrast, noise and strains. The outcomes are in line with related studies and expected values. Moreover, the framework toolbox is freely accessible and fully implemented in a single platform. (E-mail: fernando.okara@gmail.com) (c) 2012 World Federation for Ultrasound in Medicine & Biology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To assess the fetal lumbosacral spine by three-dimensional (3D) ultrasonography using volume contrast imaging (VCI) omni view method and compare reproducibility and agreement between three different measurement techniques: standard mouse, high definition mouse and pen-tablet. Methods: A comparative and prospective study with 40 pregnant women between 20 and 34+6 weeks was realized. 3D volume datasets of the fetal spine were acquired using a convex transabdominal transducer. Starting scan plane was the coronal section of fetal lumbosacral spine by VCI-C function. Omni view manual trace was selected and a parallel plane of fetal spine was drawn including interest region. Intraclass correlation coefficient (ICC) was used for reproducibility analysis. The relative difference between three used techniques was compared by chi-square test and Fischer test. Results: Pen-tablet showed better reliability (ICC = 0.987). In the relative proportion of differences, this was significantly higher for the pen-tablet (82.14%; p < 0.01). In paired comparison, the relative difference was significantly greater for the pen-tablet (p < 0.01). Conclusion: The pen-tablet showed to be the most reproductive and concordant method in the measurement of body vertebral area of fetal lumbosacral spine by 3D ultrasonography using the VCI.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background. This study evaluated the influence of circulating anti-HLA antibodies on outcomes of 97 liver allografts from deceased donors. Methods. Human leukocyte antigen (HLA) antibody screening was performed by both complement-dependent cytotoxicity (CDC) and multiparameter Luminex microsphere-based assays (Luminex assay). Results. The agreements between T- and B- cell CDC and Luminex assays were 67% and 77% for pre- and posttransplant specimens, respectively. Graft dysfunction was not associated with either positive pretransplant CDC or Luminex panel-reactive antibody (PRA) values. Likewise, positive posttransplant T- or B- cell CDC PRA values were not associated with graft dysfunction. In contrast, posttransplant Luminex PRA values were significantly higher among patients with graft dysfunction compared with subjects with good outcomes (P = .017). Conclusion. Posttransplant monitoring of HLA antibodies with Luminex methodology allowed identification of patients at high-risk for poor graft outcomes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective The aim of the present study was to investigate the lipid profiles of the hepatic and adipose tissues of Wistar rats treated for 21 days with a diet high in saturated fat (high saturated fat, n=6) or high in hydrogenated fat, that is, having 50% partially hydrogenated vegetable oil in its composition (high hydrogenated fat, n=6), and compare them to those of a control group (control group, n=6). Methods Adipose tissue and total hepatic fat were higher in the saturated fat group than in the hydrogenated fat group. Hepatic lipid peroxidation was greatest in the saturated fat group, with consequent lower hepatic vitamin E and A levels. In contrast, serum vitamin A was highest in the saturated fat group. Analysis of hepatic lipid fractions found more cholesterol and less high density lipoprotein-cholesterol in the hydrogenated fat group. The hydrogenated fat group had the highest levels of triacylglycerols, followed by the saturated fat group. Results Significant amounts of trans fatty acids were detected in the hepatic and adipose tissues of the hydrogenated fat group. Among the identified fatty acids, 18:1n9 had a higher positive association with hepatic cholesterol and triacylglycerols, and a higher negative association with high density lipoprotein-cholesterol. Partially hydrogenated vegetable oil promotes greater accumulation of cholesterol and triacylglycerols in the liver than saturated fats. Conclusion Trans fatty acids were incorporated into hepatocytes and adipocytes in a highly efficient manner.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ultrasonography has an inherent noise pattern, called speckle, which is known to hamper object recognition for both humans and computers. Speckle noise is produced by the mutual interference of a set of scattered wavefronts. Depending on the phase of the wavefronts, the interference may be constructive or destructive, which results in brighter or darker pixels, respectively. We propose a filter that minimizes noise fluctuation while simultaneously preserving local gray level information. It is based on steps to attenuate the destructive and constructive interference present in ultrasound images. This filter, called interference-based speckle filter followed by anisotropic diffusion (ISFAD), was developed to remove speckle texture from B-mode ultrasound images, while preserving the edges and the gray level of the region. The ISFAD performance was compared with 10 other filters. The evaluation was based on their application to images simulated by Field II (developed by Jensen et al.) and the proposed filter presented the greatest structural similarity, 0.95. Functional improvement of the segmentation task was also measured, comparing rates of true positive, false positive and accuracy. Using three different segmentation techniques, ISFAD also presented the best accuracy rate (greater than 90% for structures with well-defined borders). (E-mail: fernando.okara@gmail.com) (C) 2012 World Federation for Ultrasound in Medicine & Biology.