17 resultados para Laser technique


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The LA-MC-ICP-MS method applied to U-Pb in situ dating is still rapidly evolving due to improvements in both lasers and ICP-MS. To test the validity and reproducibility of the method, 5 different zircon samples, including the standard Temora-2, ranging in age between 2.2 Ga and 246 Ma, were dated using both LA-MC-ICP-MS and SHRIMP. The selected zircons were dated by SHRIMP and, after gentle polishing, the laser spot was driven to the same site or on the same zircon phase with a 213 nm laser microprobe coupled to a multi-collector mixed system. The data were collected with a routine spot size of 25 μm and, in some cases, of 15 and 40 μm. A careful cross-calibration using a diluted U-Th-Pb solution to calculate the Faraday reading to counting rate conversion factors and the highly suitable GJ-1 standard zircon for external calibrations were of paramount importance for obtaining reliable results. All age results were concordant within the experimental errors. The assigned age errors using the LA-MC-ICP-MS technique were, in most cases, higher than those obtained by SHRIMP, but if we are not faced with a high resolution stratigraphy, the laser technique has certain advantages.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The purpose of this study was to assess the effect of low level laser therapy on subjects with intra-articular temporomandibular disorders (IA-TMD), and to quantify and compare severity of signs and symptoms before, during, and after the laser applications. The sample consisted of 45 subjects randomly divided into three groups (G) of 15 subjects each: G-I: 15 individuals with IA-TMD submitted to an energy dose of 52.5 J/cm(2); G-II: dose of 105.0 J/cm(2); and G-III: placebo group (0 J/cm(2)). In all groups, the applications were performed on condylar points on the masseter and anterior temporalis muscles. Two weekly sessions were held for five weeks, totaling 10 applications. The assessed variables were: mandibular movements and painful symptoms evoked by muscle palpation. These variables were measured before starting the study, then immediately after the first, fifth, and tenth laser application, and finally, 32 days after completing the applications. The results showed that there were statistically significant differences for G-I and G-II at the level of 1% between the doses, as well as between assessments. Therefore, it was concluded that the use of low level laser increased the mean mandibular range of motion and reduced painful symptoms in the groups that received effective treatment, which did not occur in the placebo group.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We present a detailed study of the Baryscan technique, a new efficient alternative to the widespread Z-scan technique which has been demonstrated [Opt. Lett. 36:8, 2011] to reach among the highest sensitivity levels. This method is based upon the measurement of optical nonlinearities by means of beam centroid displacements with a position sensitive detector and is able to deal with any kind of lensing effect. This technique is applied here to measure pump-induced electronic refractive index changes (population lens), which can be discriminated from parasitic thermal effects by using a time-resolved Baryscan experiment. This method is validated by evaluating the polarizability variation at the origin of the population lens observed in the reference Cr3+:GSGG laser material.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives. Adductor spasmodic dysphonia (ADSD) is a focal laryngeal dystonia, which compromises greatly the quality of life of the patients involved. It is a severe vocal disorder characterized by spasms of laryngeal muscles during speech, producing phonatory breaks, forced, strained and strangled voice. Its symptoms result from involuntary and intermittent contractions of thyroarytenoid muscle during speech, which causes vocal fold to strain, pressing each vocal fold against the other and increasing glottic resistance. Botulinum toxin injection remains the gold-standard treatment. However, as injections should be repeated periodically leading to voice quality instability, a more definitive procedure would be desirable. In this pilot study we report the long-term vocal quality results of endoscopic laser thyroarytenoid myoneurectomy. Study Design. Prospective study. Methods. Surgery was performed in 15 patients (11 females and four males), aged between 29 and 73 years, diagnosed with ADSD. Voice Handicap Index (VHI) was obtained before and after surgery (median 31 months postoperatively). Results. A significant improvement in VHI was observed after surgery, as compared with baseline values (P = 0.001). The median and interquartile range for preoperative VHI was 99 and 13, respectively and 24 and 42, for postoperative VHI. Subjective improvement of voice as assessed by the patients showed median improvement of 80%. Conclusions. Because long-term follow-up showed significant improvement of voice quality, this innovative surgical technique seems a satisfactory alternative treatment of ADSD patients who seek a definite improvement of their condition.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To evaluate whether Nd:YAG laser irradiation of etched and unetched dentin through an uncured adhesive affected the microtensile bond strength (pTBS). Materials and Methods: Flat dentin surfaces were created in 19 extracted human third molars. Adper Single Bond (SB) adhesive was applied over etched (groups 1 to 3) or unetched dentin (groups 4 to 6). The dentin was then irradiated with a Nd:YAG laser through the uncured adhesive, using 0.75 or 1 W power settings, except for the control groups (groups 1 and 4). The adhesive was light cured and composite crowns were built up. After 24 h, the teeth were sectioned into beams, with cross-sectional areas of 0.49 mm(2), and were stressed under tension. Data were statistically analyzed using two-way ANOVA and Tukey's test (alpha = 5%). Dentin surfaces of fractured specimens and the interfaces of untested beams were observed under scanning electron microscopy (SEM). Results: Acid etching, laser irradiation, and their interaction significantly affected bonding (p < 0.05). Laser irradiation did not improve bonding of etched dentin to resin (p > 0.05). However, higher pTBS means were found on unetched lased dentin (groups 5 and 6), but only in comparison to group 4, where neither lasing nor etching was performed. Groups 4 to 6 showed the lowest pTBS means among all groups tested (p < 0.05). Laser irradiation did not change the characteristics of the hybrid layers created, while solidification globules were observed on lased dentin surfaces under SEM. Conclusion: Laser irradiation of dentin through the uncured adhesive did not significantly improve the pTBS in comparison to the suggested manufacturer's technique.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective To evaluate the perinatal outcomes in hydropic fetuses with congenital microcystic pulmonary lesions that underwent percutaneous, invasive, laser therapy. Method This retrospective study reviews the literature and our experience between 2004 and 2010. Characteristics of the cystic lung lesions, liquor volume (presence of polyhydramnios or not), localization of ablation (vascular vs interstitial) and gestational age at which the procedure was performed were related to outcome (survival). Results In total, 16 fetuses with congenital lung lesions underwent invasive percutaneous laser ablation, seven performed in our center and nine published cases. Survival rate was higher in fetuses with a subsequent postnatal diagnosis of bronchopulmonary sequestration (87.5%) compared with congenital adenomatoid malformation (28.6%; p?=?0.04). The technique of vascular ablation was more successful (100%) than interstitial ablation (25.0%, p?<?0.01). Conclusion Percutaneous vascular laser ablation seems to be effective for bronchopulmonary sequestration in hydropic fetuses. Outcomes were worst following interstitial ablation for microcystic congenital adenomatoid with hydrops. (C) 2012 John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was to assess the influence of Er:YAG laser pulse repetition rate on the thermal alterations occurring during laser ablation of sound and demineralized primary dentin. The morphological changes at the lased areas were examined by scanning electronic microscopy (SEM). To this end, 60 fragments of 30 sound primary molars were selected and randomly assigned to two groups (n = 30); namely A sound dentin (control) and B demineralized dentin. Each group was divided into three subgroups (n = 10) according to the employed laser frequencies: I4 Hz; II6 Hz, and III10 Hz. Specimens in group B were submitted to a pH-cycling regimen for 21 consecutive days. The irradiation was performed with a 250 mJ pulse energy in the noncontact and focused mode, in the presence of a fine water mist at 1.5 mL/min, for 15 s. The measured temperature was recorded by type K thermocouples adapted to the dentin wall relative to the pulp chamber. Three samples of each group were analyzed by SEM. The data were submitted to the nonparametric Kruskal-Wallis test and to qualitative SEM analysis. The results revealed that the temperature increase did not promote any damage to the dental structure. Data analysis demonstrated that in group A, there was a statistically significant difference among all the subgroups and the temperature rise was directly proportional to the increase in frequency. In group B, there was no difference between subgroup I and II in terms of temperature. The superficial dentin observed by SEM displayed irregularities that augmented with rising frequency, both in sound and demineralized tissues. In conclusion, temperature rise and morphological alterations are directly related to frequency increment in both demineralized and sound dentin. Microsc. Res. Tech., 2011. (c) 2011 Wiley Periodicals, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Photodynamic therapy (PDT) is a therapeutic technique mainly applied to the treatment of malignant and pre-malignant lesions, which induces cell death by the combined effect of a photosensitizer, irradiation in a proper wavelength, and molecular oxygen. One of the main limitations of PDT using 5-aminolevulinic acid (ALA) is the superficial volume of treatment, mainly due to the limited penetration of topical photosensitization. In this context, the present study investigates if a laser micromachining producing microchannels on the tissue surface could improve ALA penetration and result in an increase in the treatment depth. The laser micromachining under femtosecond regime was performed on the tissue surface of rat livers. Conventional PDT was applied and the induced depth of necrosis with or without laser micromachining was compared. The results showed an increase of more than 20% in the depth of necrosis when the femtosecond laser micromachining was performed before the treatment with the PDT.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to evaluate the shear bond strength of repairs in porcelain conditioned with laser. Sixty porcelain discs were made and six groups were formed (n = 10): G1: conditioning with laser with potency 760 mW; G2: conditioning with laser with potency 760 mW and application of 37% phosphoric acid for 15 s; G3: conditioning with laser with potency 900 mW; G4: conditioning with laser with potency 900 mW and application of 37% phosphoric acid for 15 s; G5: application of 37% phosphoric acid for 15 s (group control) and G6: application of 10% hydrofluoric acid for 2 min. The composite resin was insert of incremental layers at the porcelain surface aided with a metal matrix, and photoactivation for 20 s each increment. The specimens were submitted to a thermal cycling by 1000 cycles of 30 s in each bath with temperature between 5 and 55 degrees C. After the thermal cycling, specimens were submitted to the shear bond strength. The results were evaluated statistically through analysis of variance and Tukey's tests with 5% significance. The averages and standard deviation founded were: G1, 11.25 (+/- 3.10); G2, 12.32 (+/- 2.65); G3, 14.02 (+/- 2.38); G4, 13.44 (+/- 2,07); G5, 9.91 (-/+ 2,18); G6, 12.74 (+/- 2.67). The results showed that the femtosecond laser produced a shear bond strength of repairs in porcelain equal to the hydrofluoric acid and significantly superior to the use of phosphoric acid. Microsc. Res. Tech., 2012. (C) 2012 Wiley Periodicals, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We investigate the occurrence of the optical Kerr effect and two-photon absorption when an oil-based magnetic Fe3O4 nanoparticles colloidal suspension is illuminated with high intensity femtosecond laser pulses. The frequency of the pulses is controlled and the Z-scan technique is employed in our measurements of the nonlinear optical Kerr coefficient (n(2)) and two-photon absorption coefficient (beta). From these values it was possible to calculate the real and imaginary parts of the third-order susceptibility. We observed that increasing the pulse frequency, additional physical processes take place, increasing artificially the absolute values of n(2) and beta. The experimental conditions are discussed to assure the obtention of reliable values of these nonlinear optical parameters, which may be useful in all-optical switching and optical power limiting applications. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4723829]

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study reports the effects on micromorphology and temperature rise in human dentin using different frequencies of Er:YAG laser. Sixty human dentin fragments were randomly assigned into two groups (n = 30): carious or sound dentin. Both groups were divided into three subgroups (n = 10), according to the Er:YAG laser frequency used: 4, 6, or 10 Hz (energy: 200 mJ; irradiation distance: 12 mm; and irradiation time: 20 s). A thermocouple adapted to the tooth fragment recorded the initial temperature value (degrees C); then, the temperature was measured after the end of the irradiation (20 s). Morphological analysis was performed using images obtained with scanning electron microscope. There was no difference between the temperatures obtained with 4 and 6 Hz; the highest temperatures were achieved with 10 Hz. No difference was observed between carious and sound dentin. Morphological analyses revealed that all frequencies promoted irregular surface in sound dentin, being observed more selectively ablation especially in intertubular dentin with tubule protrusion. The caries dentin presented flat surface for all frequencies used. Both substrates revealed absence of any signs of thermal damage. It may be concluded that the parameters used in this study are capable to remove caries lesion, having acceptable limits of temperature rise and no significant morphological alterations on dentin surface. Microsc. Res. Tech. 2012. (c) 2012 Wiley Periodicals, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study analyzed the newly formed bone tissue after application of recombinant human BMP-2 (rhBMP-2) and P-1 (extracted from Hevea brasiliensis) proteins, 2 weeks after the creation of a critical bone defect in male Wistar rats treated or not with a low-intensity laser (GaAlAs 780 nm, 60 mW of power, and energy density dose of 30 J/cm2). The animals were divided into two major groups: (1) bone defect plus low-intensity laser treatment and (2) bone defect without laser irradiation. The following subgroups were also analyzed: (a) 5 mu g of pure rhBMP-2; (b) 5 mu g of pure P-1 fraction; (c) 5 mu g of rhBMP-2/monoolein gel; (d) 5 mu g of P-1 fraction/monoolein gel; (e) pure monoolein gel. Comparisons of the groups receiving laser treatment with those that did not receive laser irradiation show differences in the areas of new bone tissue. The group treated with 5 mu g of rhBMP-2 and laser irradiation was not significantly different (P >0.05) than the nonirradiated group that received the same treatment. The irradiated, rhBMP-2/monoolein gel treatment group showed a lower area of bone formation than the nonirradiated, rhBMP-2/gel monoolein treatment group (P < 0.001). The area of new bone tissue in the other nonirradiated and irradiated groups was not significantly different (P > 0.05). Furthermore, the group that received the 5 mu g of rhBMP-2 application showed the greatest bone formation. We conclude that the laser treatment did not interfere with the area of new bone tissue growth and that the greatest stimulus for bone formation involved application of the rhBMP-2 protein. Microsc. Res. Tech. 2011. (c) 2011 Wiley Periodicals, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Up-regulation of stress-activated proteins in cancer cells plays a protective role against photodynamic induced apoptosis. Post photodynamic therapy extracted normal rat liver tissue usually shows a fraction of surviving cells, the photodynamic resistant cells, residing in the necrotic region. To treat these photo-dynamic resistant cells a technique has been proposed based on fractionated drug administration of diluted photosensitizer, keeping the net concentration (5 mg/kg) constant, and subsequently varying drug light interval (DLI). Flourescence measurements were made for the presence of photosensitizer in a tissue. For qualitative analysis both histological and morphological studies were made. Although preliminary aim of this approach was not achieved but there were some interesting observation made i.e. for higher dilution of photosensitizer there was a sharp boundary between necrotic and normal portion of tissue. An increase in the absorption coefficient (alpha) from 2.7 -> 2.9 was observed as photosensitizer was diluted while the corresponding threshold dose (D (th)) persistently decreases from (0.10 -> 0.02) J/cm(2) when irradiated with a 635 nm laser fluence of 150 J/cm(2).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to evaluate the penetration of endodontic sealer into the dentin tubules, the integrity of the sealer layer perimeter, and the sealer area at the apical third after different filling techniques by confocal laser scanning microscopy (CLSM). Forty-five mandibular premolars were mechanically prepared with ProTaper files, until F5 file. Thereafter, they were filled with an epoxy-resin sealer (AH Plus) mixed with Rhodamine B dye (0.1% proportion) and allocated in three groups: Group 1, single master cone; Group 2, cold lateral compaction; and Group 3, Thermafil. For confocal laser scanning microscopy analysis, the specimens were transversely sectioned at 4 mm from the apex. The images at x10 and x40 were analyzed by Imagetool 3.0 software. Significant differences were not found among the three experimental groups according the dentin-impregnate area by the sealer (P = 0.68) and between the sealer and root canal perimeter (P = 0.18). However, root canal filling techniques were significantly different when apical sealer areas were compared (P = 0.001). Thermafil group showed smaller sealer areas (8.09%) while cold lateral compaction and gutta-percha master cone showed similar areas (17.37 and 21.18%, respectively). The dentin-impregnated area was not dependent on the root canal filling technique. Single master cone, cold lateral condensation and Thermafil techniques presented integrity of the sealer perimeter close to 100% and Thermafil resulted in a significantly thinner sealer layer. Microsc. Res. Tech. 75:12771280, 2012. (C) 2012 Wiley Periodicals, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Intestinal ischemia and reperfusion (i-I/R) is an insult associated with acute respiratory distress syndrome (ARDS). It is not known if pro- and anti-inflammatory mediators in ARDS induced by i-I/R can be controlled by low-level laser therapy (LLLT). This study was designed to evaluate the effect of LLLT on tracheal cholinergic reactivity dysfunction and the release of inflammatory mediators from the lung after i-I/R. Anesthetized rats were subjected to superior mesenteric artery occlusion (45 min) and killed after clamp release and preestablished periods of intestinal reperfusion (30 min, 2 or 4 h). The LLLT (660 nm, 7.5 J/cm(2)) was carried out by irradiating the rats on the skin over the right upper bronchus for 15 and 30 min after initiating reperfusion and then euthanizing them 30 min, 2, or 4 h later. Lung edema was measured by the Evans blue extravasation technique, and pulmonary neutrophils were determined by myeloperoxidase (MPO) activity. Pulmonary tumor necrosis factor-α (TNF-α), interleukin-10 (IL-10), intercellular adhesion molecule-1 (ICAM-1), and isoform of NO synthase (iNOS) mRNA expression were analyzed by real-time PCR. TNF-α, IL-10, and iNOS proteins in the lung were measured by the enzyme-linked immunoassay technique. LLLT (660 nm, 7.5 J/cm(2)) restored the tracheal hyperresponsiveness and hyporesponsiveness in all the periods after intestinal reperfusion. Although LLLT reduced edema and MPO activity, it did not do so in all the postreperfusion periods. It was also observed with the ICAM-1 expression. In addition to reducing both TNF-α and iNOS, LLLT increased IL-10 in the lungs of animals subjected to i-I/R. The results indicate that LLLT can control the lung's inflammatory response and the airway reactivity dysfunction by simultaneously reducing both TNF-α and iNOS.