2 resultados para Optimal placement of sensors

em Université de Montréal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aims The pubococcygeal line (PCL) is an important reference line for determining measures of pelvic organ support on sagittal-plane magnetic resonance imaging (MRI); however, there is no consensus on where to place the posterior point of the PCL. As coccyx movement produced during pelvic floor muscle (PFM) contractions may affect other measures, optimal placement of the posterior point is important. This study compared two methods for measuring the PCL, with different posterior points, on T2-weighted sagittal MRI to determine the effect of coccygeal movement on measures of pelvic organ support in older women. Methods MRI of the pelvis was performed in the midsagittal plane, at rest and during PFM contractions, on 47 community-dwelling women 60 and over. The first PCL was measured to the tip of the coccyx (PCLtip) and the second to the sacrococcygeal joint (PCLjnt). Four measures of pelvic organ support were made using each PCL as the reference line: urethrovesical junction height, uterovaginal junction height, M-line and levator plate angle. Results During the PFM contraction the PCLtip shortened and lifted (P < 0.001); the PCLjnt did not change (P > 0.05). The changes in the four measures of pelvic organ support were smaller when measured relative to the PCLtip as compared to those to the PCLjnt (P < 0.001). Conclusions Coccyx movement affected the length and position of the PCLtip, which resulted in underestimates of the pelvic-organ lift produced by the PFM contraction. Therefore, we recommend that the PCL be measured to the sacrococcygeal joint and not to the tip of the coccyx

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background and Purpose. Electrical stimulation of the pelvic floor is used as an adjunct in the conservative treatment of urinary incontinence. No consensus exists, however, regarding electrode placements for optimal stimulation of the pelvic-floor musculature. The purpose of this study was to compare two different bipolar electrode placements, one suggested by Laycock and Green (L2) the other by Dumoulin (D2), during electrical stimulation with interferential currents of the pelvic-floor musculature in continent women, using a two-group crossover design. Subjects. Ten continent female volunteers, ranging in age from 20 to 39 years (X̅=27.3, SD=5.6), were randomly assigned to one of two study groups. Methods. Each study group received neuromuscular electrical stimulation (NMES) of the pelvic-floor musculature using both electrode placements, the order of application being reversed for each group. Force of contraction was measured as pressure (in centimeters of water [cm H2O]) exerted on a vaginal pressure probe attached to a manometer. Data were analyzed using a two-way, mixed-model analysis of variance. Results. No difference in pressure was observed between the two electrode placements. Differences in current amplitude were observed, with the D2 electrode placement requiring less current amplitude to produce a maximum recorded pressure on the manometer. Subjective assessment by the subjects revealed a preference for the D2 electrode placement (7 of 10 subjects). Conclusion and Discussion. The lower current amplitudes required with the D2 placement to obtain recordings comparable to those obtained with the L2 technique suggest a more comfortable stimulation of the pelvic-floor muscles. The lower current amplitudes required also suggest that greater increases in pressure might be obtained with the D2 placement by increasing the current amplitude while remaining within the comfort threshold. These results will help to define treatment guidelines for a planned clinical study investigating the effects of NMES and exercise in the treatment of urinary stress incontinence in women postpartum.