4 resultados para High power factor (HPF)

em Repositório Institucional da Universidade Estadual de São Paulo - UNESP


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work, the author looks forward to develop a new method capable of incorporate the concepts of the Reliability Theory and Ruin Probability in Deep Foundations, in order to do a better quantification of the uncertainties, which is intrinsic in all geotechnical projects, meanly because we don't know all the properties of the materials that we work with. Using the methodologies of Decourt Quaresma and David Cabral, resistance surfaces have been developed utilizing the data achieved from the Standard Penetration Tests performed in the field of study, in conjecture with the loads defined in the executive project of the piles. The construction of resistance surfaces shows to be a very useful tool for decision making, no matter in which phase it is current on, projecting or execution. The surfaces were developed by Kriging (using the software Surfer® 12), making it easier to visualize the geotechnical profile of the field of study. Comparing the results, the conclusion was that a high safety factor doesn't mean higher security. It is fundamental to consider the loads and resistance of the piles in the whole field, carefully choosing the project methodology responsible to define the diameter and length of the piles

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, we will present an overview of the smart grid defining the three main systems that compose it: smart infrastructure system, smart management system and smart protection system. We will conceptualize a functionality of smart management system, the conservative voltage reduction, citing its benefits and its history of application. And, finally, we'll cover a test in which we reduce the nominal voltages on incandescent bulbs, CFL and LED, in the context of residential lighting, and on LED and HPS, in the context of public lighting. The test aims to check whether the voltage reduction adversely affects sources of lighting by measuring the temperature manually with a thermal imaging camera FLIR and illuminance with a LUX meter. The set of power factor, total harmonic distortion, and input power values will be collected automatically through the power quality Analyzer Fluke 345 with a probe Fluke Hall Effect Current. For residential lighting, it was found that both CFL and LED had good performance with the smallest variations in illuminance. Between both, the LED source had the lowest harmonics and the lowest power consumption, on the other hand incandescent bulbs had a bad performance as expected. Public light sources also had a good performance and obtained power factors within the standards, as opposed to the CFL and LED residential sources. The data collected clearly shows the feasibility for nominal voltage reductions. Even with small reductions, there are possibilities of savings which can be passed on to the utilities and consumers