8 resultados para Electric power - Protection
em Repositório Institucional da Universidade Estadual de São Paulo - UNESP
Resumo:
The objective of this paper is to realize the preliminary cogeneration project, to be applied on the output of a float glass furnace, aiming the energetic use of the furnace's by-products in other relevant applications on the site. It was analyzed the main points where the cycle could be installed and also the available technologies to energy recovery. After, it was chosen the installation point and the technology to be projected, evaluated the electric power generated and the cycle efficiency. Finally it was evaluated economical indicators in order to verify the project's economical feasibility
Resumo:
Across the industry, regardless of the activity which is intended, the electricity distribution must meet the current and ever growing needs of the market, aiming at reliability and process efficiency. The energy must not only be available to ensure continuity of operation, but also to avoid the costs incurred due to deficiencies and failures. The tendency to migrate to intelligent systems is undeniable and this thesis will be analyzed the advantages that made this kind technology essential, focused on the analysis of the motor control center and as sturdy equipment fit to the concept of intelligent panels. The case study compares in a real scenario the acquisition of a system of low-voltage electrical panels comparing the cost to purchase the same set of panels made with and without the concept of intelligence
Resumo:
Actually the energy efficiency is making more space in the industry, due to the search for the sustainability, the electrical energy costs reduction, the goals achievement or the efficiency of production processes. In consumer goods industries, such a beverage industry, as the work is based, the productivity is directly related to the electrical energy consumption. The development of methodologies and/or routines, in addition to some tools which allow to align more efficiently these two aspects (production and consumption of electrical energy), in the viewpoint of the Energy Conservation, is very important. In this case, the study will show the Plant Modulation concepts, a production management methodology, based in some factors related to the productive process, installed equipment, production supplies and energy cost. The proposed methodology was implanted in a plant along 2015 and show the results, in face to confirm its efficiency. Finally, in this study, it was shown the capacity of Plant Modulation to positively impact in the energy efficiency inside a big industry
Resumo:
The first approach in this work is the concept of the electric power transmission and distribution system, as well as the survey of the current condition of substations chosen to thus identify the importance of having a suitable design with respect to security due to the need to obtain the approval for the operation of the substation according to the standards valid in the country. Present the guidelines and present needs when designing improvements, thus ensuring the company for more safety and reliability. From the company's point of view is an opportunity to reduce the cost of maintenance, and the professional point of view is an opportunity that allows a comprehensive study of legal requirements for the operation of substations
Resumo:
The public consultation n° 018/2014, for review the Module 8 of Procedures of Electricity Distribution (PRODIST), conducted by National Agency of Electric Energy (ANEEL), aims to improve the regulation of power quality, considering the phenomena harmonic distortion, voltage unbalance, voltage fluctuation and short term voltage variation. These regulatory changes impact in the way of analysis and treatment, of power quality disruption, by the electricity distribution. The developed work makes a study about the applications of these new regulatory requests and hopes to contribute with a better understanding. Through power quality measurements, in distribution substations, with different load profiles (industrial, urban and rural), was obtained a real view of the system, under the aspect of power quality, to evaluate the regulation adherence to the current version and proposed. In this case study, although being in accordance with the current methodology, happened a transgression of propose. With a comparative analysis, was possible to identify some phenomena that were more flexible in the proposed revision and others with more severe monitoring
Resumo:
The objective of this work is to conduct a comparative study between the fuse key and the single-phase seccionalizador, which are protective equipment used in an electricity distribution networks. This study has also the purpose to reduce the number of electrical power breakdown. Distribution networks are not free from faults, disturbances and failures, then the occurrence of adversities on the network, which may be transient or permanent faults, results in the interruption of electric power. Thus, there are protective systems of distribution networks, which aims to ensure that the electric system continues to function. The incidence of transient faults in the distribution network of this electricity company was used to generate immediate shutdown of customers due to the bad use of fuses as protective equipment by the reclosers. With the use of the fuse switch in the distribution network, there was the immediate shutdown of customers, however, using the single-phase seccionalizador as protective equipment by the reclosers, there are three attempts to restart the electricity power. As the attempts to restart the electricity power are able to eliminate a transient fault, not causing shutdown of any costumer, with the implementation of single-phase sectionalizers to replace the fuses, the number of company shutdowns due to transient faults was reduced by 47.6%
Resumo:
It is important to ensure smoothly operation of a transmission line, sending energy to the consumption centers with minimal interruptions and safer. With this necessity, the fault location techniques have grown, in order to mitigate the impact of the fault and its correction can be more quickly and accurately. This paper presents a comparison between two different techniques of fault location, the fault location by impedance method, which uses the line parameters, the impedance per distance, voltage and current signals, and the other is the traveling wave method, which uses only a very fast analysis of time, synchronization and length between the line ends, do not using voltage and current values, but the temporal perception of the fault. Using travelling waves fault detection makes the previous knowledge of line parameters obsolete, which helps a lot network technicians and engineers with a quick and easy analysis. The methods are simulated in ATP Draw software, so both algorithms can be evaluated for their effectively and accuracy
Resumo:
Pós-graduação em Saúde Coletiva - FMB