5 resultados para Assistências a menores - Proteção

em Repositório Institucional da Universidade Estadual de São Paulo - UNESP


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we will present an overview of the smart grid defining the three main systems that compose it: smart infrastructure system, smart management system and smart protection system. We will conceptualize a functionality of smart management system, the conservative voltage reduction, citing its benefits and its history of application. And, finally, we'll cover a test in which we reduce the nominal voltages on incandescent bulbs, CFL and LED, in the context of residential lighting, and on LED and HPS, in the context of public lighting. The test aims to check whether the voltage reduction adversely affects sources of lighting by measuring the temperature manually with a thermal imaging camera FLIR and illuminance with a LUX meter. The set of power factor, total harmonic distortion, and input power values will be collected automatically through the power quality Analyzer Fluke 345 with a probe Fluke Hall Effect Current. For residential lighting, it was found that both CFL and LED had good performance with the smallest variations in illuminance. Between both, the LED source had the lowest harmonics and the lowest power consumption, on the other hand incandescent bulbs had a bad performance as expected. Public light sources also had a good performance and obtained power factors within the standards, as opposed to the CFL and LED residential sources. The data collected clearly shows the feasibility for nominal voltage reductions. Even with small reductions, there are possibilities of savings which can be passed on to the utilities and consumers

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this work is to conduct a comparative study between the fuse key and the single-phase seccionalizador, which are protective equipment used in an electricity distribution networks. This study has also the purpose to reduce the number of electrical power breakdown. Distribution networks are not free from faults, disturbances and failures, then the occurrence of adversities on the network, which may be transient or permanent faults, results in the interruption of electric power. Thus, there are protective systems of distribution networks, which aims to ensure that the electric system continues to function. The incidence of transient faults in the distribution network of this electricity company was used to generate immediate shutdown of customers due to the bad use of fuses as protective equipment by the reclosers. With the use of the fuse switch in the distribution network, there was the immediate shutdown of customers, however, using the single-phase seccionalizador as protective equipment by the reclosers, there are three attempts to restart the electricity power. As the attempts to restart the electricity power are able to eliminate a transient fault, not causing shutdown of any costumer, with the implementation of single-phase sectionalizers to replace the fuses, the number of company shutdowns due to transient faults was reduced by 47.6%

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This monograph presents the main objective of analyzing the redundancy protection systems of protection for redundancy and block of energies against accident in presses and rotating equipment. After understanding two specific goals, on this case, show the systems of protection against accidents in rotating equipments, presses and similar; and discuss the vulnerabilities of current systems of protection against accidents in presses and similar, we will propose a system of autonomous redundancy of Programmable Logic Controller (PLC) operating simultaneously taking online in the event of failure of one of the two. The methodology was worked through a revision of a variety of bibliography, and interpretation of national and international standards as well as access to research on systems, practices used in industrial and companies supplying products and of companies and energy blockages solutions

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)