3 resultados para Radial distribution function

em Repositorio Institucional de la Universidad de Málaga


Relevância:

80.00% 80.00%

Publicador:

Resumo:

X-Ray Powder Diffraction (XRPD) laboratory is a facility placed at Servicios Centrales de apoyo a la Investigación (SCAI) at University of Malaga (UMA) http://www.scai.uma.es/. This facility has three XRPD diffractometers and a diffractometer to measure high-resolution thin-films. X´Pert PRO MPD from PANalytical. This is a bragg-brentano (theta/2theta) with reflection geometry diffractometer which allows to obtain high resolution XRPD data with strictly monochromatic CuKα1 radiation (λ=1.54059Å) [Ge(111) primary monochromator] and an automatic sample charger. Moreover, it has parallel monochromatic CuKα1 radiation (λ=1.54059Å) with an hybrid Ge(220) monochromator for capillary and multiproposal (bulk samples up to 1 Kg) sample holders. The HTK1200N chamber from Anton Paar allows collecting high resolution high temperature patterns. EMPYREAN from PANalytical. This diffractometer works in reflection and transmission geometries with theta/theta goniometer, using CuKα1,2 radiation (λ=1.5418Å), a focusing X-ray mirror and a ultra-fast PIXCEL 3D detector with 1D and 2D collection data modes (microstructural and preferred orientation analysis). Moreover, the TTK450N chamber allows low temperature and up to 450ºC studies. A D8 ADVANCE (BRUKER) was installed in April 2014. It is the first diffractometer in Europe equipped with a Johansson Ge(111) primary monochromator, which gives a strictly monochromatic Mo radiation (λ=0.7093 Å) [1]. It works in transmission mode (with a sample charger) with this high resolution configuration. XRPD data suitable for PDF (Pair Distribution Function) analysis can be collected with a capillary sample holder, due to the high energy and high resolution capabilities of this diffractometer. Moreover, it has a humidity chamber MHC-trans from Anton Paar working on transmission mode with MoKα1 (measurements can be collected at 5 to 95% of relative humidity (from 20 to 80 ºC) and up to 150ºC [2]). Furthermore, this diffractometer also has a reaction chamber XRK900 from Anton Paar (which uses CuKα1,2 radiation in reflection mode), which allows data collection from room temperature to 900ºC with up to 10 bar of different gases. Finally, a D8 DISVOVER A25 from BRUKER was installed on December 2014. It has a five axis Euler cradler and optics devices suitable for high resolution thin film data collection collected in in-plane and out-of-plane modes. To sum up, high-resolution thin films, microstructural, rocking-curve, Small Angle X-ray Scattering (SAXS), Grazing incident SAXS (GISAXS), Ultra Grazing incident diffraction (Ultra-GID) and microdiffraction measurements can be performed with the appropriated optics and sample holders. [1] L. León-Reina, M. García-Maté, G. Álvarez-Pinazo, I. Santacruz, O. Vallcorba, A.G. De la Torre, M.A.G. Aranda “Accuracy in Rietveld quantitative phase analysis: a comparative study of strictly monochromatic Mo and Cu radiations” J. Appl. Crystallogr. 2016, 49, 722-735. [2] J. Aríñez-Soriano, J. Albalad, C. Vila-Parrondo, J. Pérez-Carvajal, S. Rodríguez-Hermida, A. Cabeza, F. Busqué, J. Juanhuix, I. Imaz, Daniel Maspoch “Single-crystal and humidity-controlled powder diffraction study of the breathing effect in a metal-organic framework upon water adsorption/desorption” Chem. Commun., 2016, DOI: 10.1039/C6CC02908F.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

There are diferent applications in Engineering that require to compute improper integrals of the first kind (integrals defined on an unbounded domain) such as: the work required to move an object from the surface of the earth to in nity (Kynetic Energy), the electric potential created by a charged sphere, the probability density function or the cumulative distribution function in Probability Theory, the values of the Gamma Functions(wich useful to compute the Beta Function used to compute trigonometrical integrals), Laplace and Fourier Transforms (very useful, for example in Differential Equations).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper shows that the proposed Rician shadowed model for multi-antenna communications allows for the unification of a wide set of models, both for multiple-input multiple-output (MIMO) and single- input single-output (SISO) communications. The MIMO Rayleigh and MIMO Rician can be deduced from the MIMO Rician shadowed, and so their SISO counterparts. Other more general SISO models, besides the Rician shadowed, are included in the model, such as the κ-μ, and its recent generalization, the κ-μ shadowed model. Moreover, the SISO η-μ and Nakagami-q models are also included in the MIMO Rician shadowed model. The literature already presents the probability density function (pdf) of the Rician shadowed Gram channel matrix in terms of the well-known gamma- Wishart distribution. We here derive its moment generating function in a tractable form. Closed- form expressions for the cumulative distribution function and the pdf of the maximum eigenvalue are also carried out.